977 resultados para Flow Field
Resumo:
33rd IAHR Congress: Water Engineering for a Sustainable Environment
Resumo:
The localization of magma melting areas at the lithosphere bottom in extensional volcanic domains is poorly understood. Large polygenetic volcanoes of long duration and their associated magma chambers suggest that melting at depth may be focused at specific points within the mantle. To validate the hypothesis that the magma feeding a mafic crust, comes from permanent localized crustal reservoirs, it is necessary to map the fossilized magma flow within the crustal planar intrusions. Using the AMS, we obtain magmatic flow vectors from 34 alkaline basaltic dykes from São Jorge, São Miguel and Santa Maria islands in the Azores Archipelago, a hot-spot related triple junction. The dykes contain titanomagnetite showing a wide spectrum of solid solution ranging from Ti-rich to Ti-poor compositions with vestiges of maghemitization. Most of the dykes exhibit a normal magnetic fabric. The orientation of the magnetic lineation k1 axis is more variable than that of the k3 axis, which is generally well grouped. The dykes of São Jorge and São Miguel show a predominance of subhorizontal magmatic flows. In Santa Maria the deduced flow pattern is less systematic changing from subhorizontal in the southern part of the island to oblique in north. These results suggest that the ascent of magma beneath the islands of Azores is predominantly over localized melting sources and then collected within shallow magma chambers. According to this concept, dykes in the upper levels of the crust propagate laterally away from these magma chambers thus feeding the lava flows observed at the surface.
Resumo:
Hyperspectral instruments have been incorporated in satellite missions, providing large amounts of data of high spectral resolution of the Earth surface. This data can be used in remote sensing applications that often require a real-time or near-real-time response. To avoid delays between hyperspectral image acquisition and its interpretation, the last usually done on a ground station, onboard systems have emerged to process data, reducing the volume of information to transfer from the satellite to the ground station. For this purpose, compact reconfigurable hardware modules, such as field-programmable gate arrays (FPGAs), are widely used. This paper proposes an FPGA-based architecture for hyperspectral unmixing. This method based on the vertex component analysis (VCA) and it works without a dimensionality reduction preprocessing step. The architecture has been designed for a low-cost Xilinx Zynq board with a Zynq-7020 system-on-chip FPGA-based on the Artix-7 FPGA programmable logic and tested using real hyperspectral data. Experimental results indicate that the proposed implementation can achieve real-time processing, while maintaining the methods accuracy, which indicate the potential of the proposed platform to implement high-performance, low-cost embedded systems, opening perspectives for onboard hyperspectral image processing.
Resumo:
The currently used pre-exposure anti-rabies immunization schedule in Brazil is the one called 3+1, employing suckling mouse brain vaccine (3 doses on alternate days and the last one on day 30). Although satisfactory results were obtained in well controlled experimental groups using this immunization schedule, in our routine practice, VNA levels lower than 0.5 IU/ml are frequently found. We studied the pre-exposure 3+1 schedule under field conditions in different cities on the State of São Paulo, Brazil, under variable and sometimes adverse circumstances, such as the use of different batches of vaccine with different titers, delivered, stored and administered under local conditions. Fifty out of 256 serum samples (19.5%) showed VNA titers lower than 0.5 IU/ml, but they were not distributed homogeneously among the localities studied. While in some cities the results were completely satisfactory, in others almost 40% did not attain the minimum VNA titer required. The results presented here, considered separately, question our currently used procedures for human pre-exposure anti-rabies immunization. The reasons determining this situation are discussed.
Resumo:
Atualmente o gás natural é a principal fonte de energia utilizada pela maioria dos europeus nos setores doméstico, terciário e industrial. É considerado a alternativa energética do futuro e a mais ecologicamente correta de que podemos dispor, numa escala compatível com as elevadas necessidades energéticas da Humanidade a nível global. Aliado a estes factos, surgem cada vez mais regras de boa prática, normas e legislação, nomeadamente especificações técnicas de forma a regular o setor e dotar as entidades intervenientes na conceção e controlo de uma instalação de rede de gás, de um conhecimento mais detalhado e atualizado sobre esta matéria. Esta dissertação pretende assim contribuir para a melhoria e modernização do desempenho de todos os que exercem funções neste setor, com vista ao aperfeiçoamento da qualidade e utilidade dos seus serviços. Este trabalho reúne o conjunto de informação técnica presente na legislação e normas de forma a preencher a eventual falha do conhecimento neste ramo por parte destes profissionais dotando-os de um conhecimento mais aprofundado, de modo a que possam executar corretamente e de forma eficaz o seu trabalho. Por outro lado, esta dissertação tem como objetivo o projeto e desenvolvimento de uma rede de distribuição de gás natural aplicado a três redes concretas: rede de distribuição, edifício e moradia. A conceção do projeto de instalação de gás inicia-se com a recolha de informação, seguindo-se o desenvolvimento do estudo do traçado. Assim, estão reunidas as condições para dimensionar e providenciar a escolha de materiais mais adequados para a execução da obra. A metodologia de dimensionamento adotada teve por base a equação dos gases perfeitos e a fórmula de Renouard simplificada, encontrando-se implementada numa folha de cálculo. Esta ferramenta de cálculo aliada à metodologia permite realizar de forma expedita o correto dimensionamento de uma rede de gás, bem como apurar se a velocidade de escoamento se encontra em conformidade com o definido no projeto.
Resumo:
O presente relatório sintetiza as atividades de pesquisa e de campo desenvolvidas no estágio realizado na empresa Caetano Aeronautic, no âmbito da unidade curricular “Dissertação/Projeto/Estágio Profissional do Mestrado em Engenharia de Instrumentação e Metrologia, do Instituto Superior de Engenharia do Porto. O estágio teve como principal objetivo adquirir competências para a realização da inspeção de componentes aeronáuticos, atividade presente ao longo de todo o processo produtivo da empresa. O setor aeronáutico é um setor amplamente tecnológico e o seu Sistema de Gestão de Qualidade tem um vasto suporte documental associado. Numa primeira fase do trabalho foi feito um estudo intensivo do Sistema de Gestão da Qualidade da Caetano Aeronautic, de forma a se perceber quais os documentos inerentes ao sistema e respetivos conteúdos. Em seguida, foi necessário realizar uma análise ao fluxo produtivo da organização, para se perceber todo o processo de produção de um componente aeronáutico e documentação associada. Visto que todo o trabalho de inspeção de componentes exige conhecimentos sólidos na área da Metrologia dimensional, tornou-se fundamental consolidar competências nesta área, objetivo que foi concretizado ao longo do estágio. Com vista a contribuir para o melhoramento do processo de inspeção dos componentes aeronáuticos na empresa, foram identificados e analisados no decorrer do trabalho realizado, os problemas presentes quer ao nível da produção quer da inspeção e feitas propostas de melhoria, postas em prática sempre que possível.
Resumo:
The determination of the rabies neutralizing antibody (VNA) response after immunization against rabies is an acceptable index of the efficacy of a vaccine and a successful treatment. Several tests have been developed in attempt to improve the assessment of VNA, from mice inoculation to cell-culture fluorescence inhibition tests. All of them, however, present special difficulties in terms of reading or accuracy. The present study describes a neutralization test performed in cell-culture appraised by flow cytometry (FC). Serial dilutions of the serum samples were mixed in vitro with rabies virus before the addition of BHK-21 cells. After 24h-incubation, cells were released by trypsin treatment, fixed and permeabilized with a p-formaldehyde solution and stained with a rabies virus nucleocapsid protein-specific antibody conjugate. The percentage of virus infection inhibition caused by specific antibodies present in the serum were evaluated in a Beckton & Dickinson FACSCalibur® flow cytometer. A correlation curve between the IU/ml content and the percentage of infective inhibition was built with a reference serum and the VNA titers of serum samples were obtained by extrapolation. Titers obtained by FC and standard test showed an effective pairing results (p < 0.01), with a correlation coefficient (r) = 0.7. These results permit to envisage the FC as a suitable technique to evaluate VNA in sera from immunized animals and likely in human serum samples. Nevertheless, new studies comparing FC to gold-standard techniques are required for determining the FC values of Sensibility and Specificity .
Resumo:
E. coli was submitted to a 5G electromagnetic field generated by a alternate 60 Hz voltage source. The differences on growth and glucose consume in control and exposed groups were evaluated using the non-parametric Mann-Whitney U-test. There was a significant difference in glucose consume and growth in E. coli after 8 hours of exposition to electromagnetic field. It can be concluded that electromagnetic field had a positive effect in consume of glucose and growth of E. coli. The cause of these results can be explained by an increasing of glucose entrance through membrane due to the stimulated transport system via Facility Diffusion or cyclotron resonance. The growth can be caused by shortening of lag phase and excitement of log phase.
Resumo:
This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.
Resumo:
Accepted in 13th IEEE Symposium on Embedded Systems for Real-Time Multimedia (ESTIMedia 2015), Amsterdam, Netherlands.
Resumo:
Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.
Resumo:
The local fractional Burgers’ equation (LFBE) is investigated from the point of view of local fractional conservation laws envisaging a nonlinear local fractional transport equation with a linear non-differentiable diffusion term. The local fractional derivative transformations and the LFBE conversion to a linear local fractional diffusion equation are analyzed.
Resumo:
Persistence of Bacillus thuringiensis var. israelensis (Vectobac WDG) and methoprene (Metoprag S-2G) was evaluated against Aedes aegypti late third instar larvae of the Rockefeller strain in a semi-field bioassay. Tests were performed in Rio de Janeiro, using containers made of plastic, iron, concrete and asbestos, placed in a shaded area. The formulations used were 0.2 g of Vectobac-WDG and 1g of Metoprag S-2G per 100 liters of water in house storage containers. Vectobac WDG was tested twice, in March and in April/May, 2002. In March (temperature ranging from 21.5 to 39.3 ºC), 70-100% mortality was observed by the 7th day and declined abruptly thereafter. No significant differences were observed among the container types. In April/May (18.6 to 34.8 ºC) mortality was higher than 70% to 30-36 days in all cases, except in the iron container (40% mortality on the 12th day). Metoprag S-2G was evaluated in April/May, 2002, and induced mortality higher than 70% up to 15 days in the plastic and iron containers and only seven days in the concrete container. In the asbestos container, maximal mortality was achieved on day one post-treatment (66%). Our results point to a low persistence of both formulations in the weather conditions of Rio de Janeiro.
Resumo:
In this paper we present a set of field tests for detection of human in the water with an unmanned surface vehicle using infrared and color cameras. These experiments aimed to contribute in the development of victim target tracking and obstacle avoidance for unmanned surface vehicles operating in marine search and rescue missions. This research is integrated in the work conducted in the European FP7 research project Icarus aiming to develop robotic tools for large scale rescue operations. The tests consisted in the use of the ROAZ unmanned surface vehicle equipped with a precision GPS system for localization and both visible spectrum and IR cameras to detect the target. In the experimental setup, the test human target was deployed in the water wearing a life vest and a diver suit (thus having lower temperature signature in the body except hands and head) and was equipped with a GPS logger. Multiple target approaches were performed in order to test the system with different sun incidence relative angles. The experimental setup, detection method and preliminary results from the field trials performed in the summer of 2013 in Sesimbra, Portugal and in La Spezia, Italy are also presented in this work.
Resumo:
Paper presented at the 5th European Conference Economics and Management of Energy in Industry, Vilamoura, Algarve. Apr. 14-17, 2009, 11p. URL: http:// www.cenertec.pt/ecemei/