978 resultados para Electric power factor
Resumo:
Wave radiation by a conductor carrying a steady current in both a polar, highly eccentric, low perijove orbit, as in NASA's planned Juno mission, and an equatorial low Jovian orbit (LJO) mission below the intense radiation belts, is considered. Both missions will need electric power generation for scientific instruments and communication systems. Tethers generate power more efficiently than solar panels or radioisotope power systems (RPS). The radiation impedance is required to determine the current in the overall tether circuit. In a cold plasma model, radiation occurs mainly in the Alfven and fast magnetosonic modes, exhibiting a large refraction index. The radiation impedance of insulated tethers is determined for both modes and either mission. Unlike the Earth ionospheric case, the low-density, highly magnetized Jovian plasma makes the electron gyrofrequency much larger than the plasma frequency; this substantially modifies the power spectrum for either mode by increasing the Alfven velocity. Finally, an estimation of the radiation impedance of bare tethers is considered. In LJO, a spacecraft orbiting in a slow downward spiral under the radiation belts would allow determining magnetic field structure and atmospheric composition for understanding the formation, evolution, and structure of Jupiter. Additionally, if the cathodic contactor is switched off, a tether floats electrically, allowing e-beam emission that generate auroras. On/off switching produces bias/current pulses and signal emission, which might be used for Jovian plasma diagnostics.
Resumo:
On 22nd February '96, the space mission STS 75 started ,from the NASA facilities at Cape Canaveral. Such a mission consists in the launch of the shuttle Columbia in order to carry out two experiments in the space: the TSS 1R (Tethered Satellite Sistem 1 Refliight) and the USMP (United States Microgravity Payload). The TSS 1R is a replica of a similar mission TSS 1 '92. The TSS space programme is a bilateral scientific cooperation between the USA space agency NASA (National Aeronautics and Space Agency) and the ASI (Italian Space Agency. The TSS 1R system consists on the shuttle Columbia which deploys, up-ward, by means a conducting tether 20 km long, a spherical satellite (1.5 mt diameter) containing scientific instrumentation. This system, orbiting at about 300 km from the Earth's surface, represents, presently, the largest experimental space structure, Due to its dimensions, flexibility and conducting properties of the tether, the system interacts, in a quite complex manner, wih the earth magnetic field and the ionospheric plasma, in a way that the total system behaves as an electromagnetic radiating antenna as well as an electric power generator. Twelve scientific experiments have been assessed by US and Italian scientists in order to study the electro dynamic behaviour of the structure orbiting in the ionos phere. Two experiments have been prepared in the attempt to receive on the Earth's surface possible electromagnetic events radiated by the TSS 1R. The project EMET (Electro Magnetic Emissions from Tether),USA and the project OESEE (Observations on the Earth Surface of Electromagnetic Emissions) Italy, consist in a coordinated programme of passive detection of such possible EM emissions. This detection will supply the verification of some thoretical hypotheses on the electrodynamic interactions between the orbiting system, the Earth's magnetic field and the ionospheric plasma with two principal aims as the technological assesment of the system concept as well as a deeper knowledge of the ionosphere properties for future space applications. A theoretical model that keeps the peculiarities of tether emissionsis being developed for signal prediction at constant tether current. As a step previous to the calculation of the expected ground signal , the Alfven-wave signature left by the tether far back in the ionosphere has been determined. The scientific expectations from the combined effort to measure the entity of those perturbations will be outlined taking in to account the used ground track sensor systems.
Resumo:
En el artículo se discute el papel de la energía hidroeléctrica en el marco del sistema eléctrico español, donde existe una elevada penetración de energías no gestionables con una tendencia clara a aumentar en los próximos años. El desarrollo de nuevas centrales hidroeléctricas se basará probablemente en centrales reversibles. La energía hidroeléctrica es una tecnología madura y eficiente para el almacenamiento de energía a gran escala y contribuye por tanto de manera decisiva a la integración de fuentes renovables no gestionables. Los beneficios obtenidos con la operación punta-valle pueden ser insuficientes para compensar el coste de una nueva central. Sin embargo, los ingresos obtenidos pueden incrementarse sustancialmente mediante su participación en los servicios de ajuste del sistema. Ello requeriría un diseño apropiado del mercado eléctrico. La contribución de las centrales hidráulicas reversibles al balance producción-consumo puede extenderse a las horas valle utilizando, bien bombeo en velocidad variable o bien una configuración de cortocircuito hidráulico. La necesidad de mitigar los efectos hidrológicos aguas abajo de las centrales hidroeléctricas puede introducir algunas restricciones en la operación que limitaría de algún modo los servicios descritos más arriba. Sin embargo, cabe esperar que los efectos ambientales provocados por las centrales hidráulicas reversibles sean significativamente menores. In this paper the role of hydropower in electric power systems is discussed, in the framework of the Spanish system, where a high penetration of intermittent power sources exists, showing a clear trend to increase in next years. The development of new hydro power facilities will be likely based on pumped storage hydro power plants. Hydropower is a mature and efficient technology for large-scale energy storage and therefore represents a key contribution for the integration of intermittent power sources, such as wind or photovoltaic. The benefits obtained from load shifting may be insufficient to compensate the costs of a new plant. However, the obtained revenues can significantly increase through its contribution to providing ancillary services. This would require an appropriate design of the electricity market. The contribution of pumped storage hydro power plants to balancing services can be extended to off-peak hours, using either variable speed pumping or the hydraulic shortcircuit configuration. The need to mitigate hydrological effects downstream of hydro plants may introduce some operational constraints which could limit to some extent the services described above. However environmental effects caused by pumped storage hydro power plants are expected to be significantly smaller.
Resumo:
We present a practical implementation of a solar thermophotovoltaic (TPV) system. The system presented in this paper comprises a sunlight concentrator system, a cylindrical cup-shaped absorber/emitter (made of tungsten coated with HfO2), and an hexagonal-shaped water-cooled TPV generator comprising 24 germanium TPV cells, which is surrounding the cylindrical absorber/emitter. This paper focuses on the development of shingled TPV cell arrays, the characterization of the sunlight concentrator system, the estimation of the temperature achieved by the cylindrical emitters operated under concentrated sunlight, and the evaluation of the full system performance under real outdoor irradiance conditions. From the system characterization, we have measured short-circuit current densities up to 0.95 A/cm2, electric power densities of 67 mW/cm2, and a global conversion efficiency of about 0.8%. To our knowledge, this is the first overall solar-to-electricity efficiency reported for a complete solar thermophotovoltaic system. The very low efficiency is mainly due to the overheating of the cells (up to 120 °C) and to the high optical concentrator losses, which prevent the achievement of the optimum emitter temperature. The loss analysis shows that by improving both aspects, efficiencies above 5% could be achievable in the very short term and efficiencies above 10% could be achieved with further improvements.
Resumo:
Recently there has been an important increase in electric equipment, as well as, electric power demand in aircrafts applications. This prompts to the necessity of efficient, reliable, and low-weight converters, especially rectifiers from 115VAC to 270VDC because these voltages are used in power distribution. In order to obtain a high efficiency, in aircraft application where the derating in semiconductors is high, normally several semiconductors are used in parallel to decrease the conduction losses. However, this is in conflict with high reliability. To match both goals of high efficiency and reliability, this work proposes an interleaved multi-cell rectifier system, employing several converter cells in parallel instead of parallel-connected semiconductors. In this work a 10kW multi-cell isolated rectifier system has been designed where each cell is composed of a buck type rectifier and a full bridge DC-DC converter. The implemented system exhibits 91% of efficiency, high power density (10kW/10kg), low THD (2.5%), and n−1 fault tolerance which complies, with military aircraft standards.
Resumo:
This paper proposes a method for the identification of different partial discharges (PDs) sources through the analysis of a collection of PD signals acquired with a PD measurement system. This method, robust and sensitive enough to cope with noisy data and external interferences, combines the characterization of each signal from the collection, with a clustering procedure, the CLARA algorithm. Several features are proposed for the characterization of the signals, being the wavelet variances, the frequency estimated with the Prony method, and the energy, the most relevant for the performance of the clustering procedure. The result of the unsupervised classification is a set of clusters each containing those signals which are more similar to each other than to those in other clusters. The analysis of the classification results permits both the identification of different PD sources and the discrimination between original PD signals, reflections, noise and external interferences. The methods and graphical tools detailed in this paper have been coded and published as a contributed package of the R environment under a GNU/GPL license.
Resumo:
El alcance de este proyecto es dimensionar un sistema de trigeneración para una industria papelera. El proyecto se realizará en base a la propuesta de la nueva reforma de la ley energética, por la cual no se podrá vender la energía eléctrica generada a la red sino que toda la energía generada ha de ser utilizada de forma exclusiva para autoconsumo. En primer lugar se desarrolla un proceso de selección de los equipos y tecnologías para la cogeneración, que posteriormente servirá para el dimensionamiento de la planta, en el cual se elegirá la tecnología oportuna para la generación de energía eléctrica y energía térmica, tanto en forma de frío como de calor. Con este estudio se podrá calcular el ahorro conseguido por el nuevo sistema propuesto, comparado con los costes de la generación por sistemas convencionales y desde ese ahorro, analizar la rentabilidad y viabilidad del proyecto en función de la inversión inicial que supone dicho proyecto. Abstract The scope of this project is to measure a trigeneration system for paper industry. The project will be based on the proposal of the new reform of the energy law, by which the electricity generated to the network may not be sold but that all the generated energy has to be used exclusively for self-consumption. First of all the study develops a process of selection of the equipment and technologies for cogeneration, which subsequently will be used for the dimensioning of the plant, the result will be an election of the appropriate technology for the generation of electric power and heat energy, both in the form of cold and heat. With this study the savings achieved by the new proposed system will be estimated, compared with costs of conventional generation and from these savings, analized for profitability and viability of the project on the basis of the initial investment involved in this project.
Resumo:
El proyecto tiene como objeto analizar desde el punto de vista técnico-económico las posibilidades para mejorar el factor de potencia en los consumos auxiliares de la Central térmica Litoral, perteneciente a Endesa Generación. Debido a un cambio normativo, las tarifas de acceso a las redes de transporte y distribución de energía eléctrica aplicarán ahora también a los consumos propios de las empresas productoras de electricidad dentro del ámbito de aplicación de las tarifas de acceso. Como la energía reactiva se facturará en función del factor de potencia se propone para su compensación la instalación de bancos de condensadores para mejorar el mismo y disminuir la penalización. Para el dimensionamiento de los bancos se han utilizado los consumos horarios de los años 2012 y 2013 de tres fronteras: grupos 1 y 2 de 400 kV y los transformadores auxiliares de arranque (OTAAs) de 6 kV , teniendo en cuenta las peculiaridades de una Central de Generación, ya que sólo serán objeto de estudio (a efecto de penalizaciones) las horas en las que el grupo está parado o arrancando. El resultado final muestra la diferencia en cuanto a los periodos de amortización de una instalación con generación y sin generación, siendo esta última más rentable económicamente. ABSTRACT The goal of this project is to analyse the possibilities to better the power factor in the auxiliary consumption of the Thermal Plant Litoral from an economic and technical viewpoint. Due to a normative changes, the access price rates for the transportation and distribution of electrical energy, will also apply now to the electricity productive companies own consumption within the scope of the access rate. Since reactive power is invoiced based on the potency factor, we propose the installation of capacitor banks to improve the aforementioned power factor as compensation so as to reduce sanctions. We have used the time profiles from 2012 and 2013 to dimension the banks, using 3 borders: Group 1 and 2 (400 kV) and the auxiliary starter transformers (OTAA's) of 6kV, taking into account the special characteristics of a Generation Plant , since we will only study the hours that the group was shut down or powering up (since these are what the penalties cover). The final result shows the difference in regards to repayment periods for both generating and nongenerating installation, being the aforesaid the most economically worthwile of the two
Resumo:
La situación energética actual es insostenible y como consecuencia se plantea un escenario próximo orientado a conseguir un futuro energético sostenible que permita el desarrollo económico y el bienestar social. La situación ambiental actual está afectada directamente por la combustión de combustibles fósiles que en 2013 constituyeron el 81% de la energía primaria utilizada por el ser humano y son la principal fuente antropogénica de gases de efecto invernadero. Los informes del IPCC1, ponen de manifiesto que el cambio climático se ha consolidado durante los últimos años y en la conferencia de la ONU sobre cambio climático de París que se celebrará a finales de 2015, se pretende que los gobiernos suscriban un acuerdo universal para limitar las emisiones de gases de efecto invernadero y evitar que el incremento de la temperatura media global supere los 2°C. Por otra parte, en el interior de las ciudades es especialmente preocupante, por su efecto directo sobre la salud humana, el impacto ambiental producido por las emisiones de NOx que generan el transporte de personas y mercancías. El sector del transporte fue responsable en 2012 del 27,9% del consumo final de energía. Una vez expuesto el escenario energético y ambiental actual, en esta tesis, se analiza la eficiencia de un sistema autónomo fotovoltaico para la carga de baterías de vehículos eléctricos y el uso del mismo con otras cargas, con el objetivo de aprovechar al máximo la energía eléctrica generada y contribuir a la utilización de energía limpia que no produzca impacto ambiental. Como primer paso para el desarrollo de la tesis se hizo un estudio de trabajos previos comenzando por las primeras aplicaciones de la energía fotovoltaica en los vehículos solares para después pasar a trabajos más recientes enfocados al suministro de energía a los vehículos eléctricos. También se hizo este estudio sobre las metodologías de simulación en los sistemas fotovoltaicos y en el modelado de distintos componentes. Posteriormente se eligieron, dentro de la amplia oferta existente en el mercado, los componentes con características técnicas más adecuadas para este tipo de instalaciones y para las necesidades que se pretenden cubrir. A partir de los parámetros técnicos de los componentes elegidos para configurar la instalación autónoma y utilizando modelos contrastados de distintos componentes, se ha desarrollado un modelo de simulación en ordenador del sistema completo con el que se han hecho simulaciones con distintos modos de demanda de energía eléctrica, según los modos de carga disponibles en el vehículo eléctrico para corriente alterna monofásica de 230 V. También se han simulado distintos tamaños del generador fotovoltaico y del sistema de acumulación de energía eléctrica para poder determinar la influencia de estos parámetros en los balances energéticos del sistema. Utilizando recursos propios el doctorando ha realizado la instalación real de un sistema fotovoltaico que incluye sistema de acumulación e inversor en un edificio de su propiedad. Para la realización de la tesis, La Fundación de Fomento e Innovación Industrial (F2I2) ha facilitado al doctorando un dispositivo que permite realizar la alimentación del vehículo eléctrico en modo 2 (este modo emplea un adaptador que incorpora dispositivos de seguridad y se comunica con el vehículo permitiendo ajustar la velocidad de recarga) y que ha sido necesario para los trabajos desarrollados. Se ha utilizado la red eléctrica como sistema de apoyo de la instalación fotovoltaica para permitir la recarga en el modo 2 que requiere más potencia que la proporcionada por el sistema fotovoltaico instalado. Se han analizado mediante simulación distintos regímenes de carga que se han estudiado experimentalmente en la instalación realizada, a la vez que se han hecho ensayos que se han reproducido mediante simulación con los mismos valores de radiación solar y temperatura con objeto de contrastar el modelo. Se han comparado los resultados experimentales con los obtenidos mediante simulación con objeto de caracterizar el comportamiento del sistema de acumulación (energía eléctrica suministrada y tensión de salida en las baterías) y del generador fotovoltaico (energía eléctrica fotovoltaica suministrada). Por último, se ha realizado un estudio económico de la instalación autónoma fotovoltaica ejecutada y simulada. En el mismo se ha planteado la utilización de fondos propios (como realmente se ha llevado a cabo) y la utilización de financiación, para determinar dos posibles escenarios que pudieran ser de utilidad a un propietario de vehículo eléctrico. Se han comparado los resultados obtenidos en los dos escenarios propuestos del estudio económico del sistema, en cuanto a los parámetros de tiempo de retorno de la inversión, valor actual neto de la inversión y tasa interna de retorno de la misma. Las conclusiones técnicas obtenidas, permiten la utilización del sistema con los modos de carga ensayados y otro tipo de cargas que aprovechen la generación eléctrica del sistema. Las baterías ofrecen mejor comportamiento cuando el aporte fotovoltaico está presente, pero no considera adecuado la conexión de cargas elevadas a un sistema de acumulación de gel (plomo-acido) como el que se ha utilizado, debido al comportamiento de este tipo de baterías ante demandas de intensidad de corriente eléctrica elevadas. Por otra parte, el comportamiento de este tipo de baterías con valores de intensidad de corriente eléctrica inferiores a 10 A en ausencia de energía fotovoltaica, con el objetivo de utilizar la generación de energía eléctrica diaria acumulada en el sistema, sí resulta interesante y ofrece un buen comportamiento del sistema de acumulación. Las circunstancias actuales de mercado, que carece de sistemas de acumulación de litio con precios de compra interesantes, no han permitido poder experimentar este sistema de acumulación en la instalación autónoma fotovoltaica ejecutada, tampoco se ha podido obtener el favor de ningún fabricante para ello. Actualmente hay disponibles sistemas de acumulación en litio que no se comercializan en España y que serían adecuados para el sistema de acumulación de energía propuesto en este estudio, que deja abierta las puertas para futuros trabajos de investigación. Las conclusiones económicas obtenidas, rentabilizan el uso de una instalación autónoma fotovoltaica con consumo instantáneo, sin acumulación de energía eléctrica. El futuro de conexión a red por parte de estas instalaciones, cuando se regule, aportará un incentivo económico para rentabilizar con menos tiempo las instalaciones autónomas fotovoltaicas, esto también deja la puerta abierta a futuros trabajos de investigación. El sistema de acumulación de energía aporta el mayor peso económico de inversión en este tipo de instalaciones. La instalación estudiada aporta indicadores económicos que la hacen rentable, pero se necesitaría que los precios de acumulación de la energía en sistemas eficientes estén comprendidos entre 100-200 €/kWh para que el sistema propuesto en este trabajo resulte atractivo a un potencial propietario de un vehículo eléctrico. ABSTRACT The current energy situation is untenable; it poses a scenario next focused on reaching a sustainable energy future, to allow economic development and social welfare. The environmental current situation is affected directly by the combustion of fossil fuels that in 2013 constituted 81 % of the primary energy used by the human being and they are the principal source human of greenhouse gases. The reports of the IPCC2, they reveal that the climate change has consolidated during the last years and in the conference of the UNO on climate change of Paris that will be celebrated at the end of 2015, there is claimed that the governments sign a universal agreement to limit the emission of greenhouse gases and to prevent that the increase of the global average temperature overcomes them 2°C. On the other hand, inside the cities it is specially worrying, for his direct effect on the human health, the environmental impact produced by the NOx emissions that generate the persons' transport and goods. The sector of the transport was responsible in 2012 of 27,9 % of the final consumption of energy. Once exposed the scenario and present environmental energy, in this thesis, it has analyzed the efficiency of an autonomous photovoltaic system for charging electric vehicles, and the use of the same with other workloads, with the objective to maximize the electrical energy generated and contribute to the use of clean energy that does not produce environmental impact. Since the first step for the development of the thesis did to itself a study of previous works beginning for the first applications of the photovoltaic power in the solar vehicles later to go on to more recent works focused on the power supply to the electrical vehicles. Also this study was done on the methodologies of simulation in the photovoltaic systems and in the shaped one of different components. Later they were chosen, inside the wide existing offer on the market, the components with technical characteristics more adapted for this type of facilities and for the needs that try to cover. From the technical parameters of the components chosen to form the autonomous installation and using models confirmed of different components, a model of simulation has developed in computer of the complete system with which simulations have been done by different manners of demand of electric power, according to the available manners of load in the electrical vehicle for single-phase alternating current of 230 V. Also there have been simulated different sizes of the photovoltaic generator and of the system of accumulation of electric power to be able to determine the influence of these parameters in the energy balances of the system. Using own resources the PhD student has realized a real installation of a photovoltaic system that includes system of accumulation and investing in a building of his property. For the accomplishment of the thesis, The Foundation of Promotion and Industrial Innovation (F2I2) it has facilitated to the PhD student a device that allows to realize the supply of the electrical vehicle in way 2 (this way uses an adapter that incorporates safety devices and communicates with the vehicle allowing to fit the speed of recharges) and that has been necessary for the developed works. The electrical network has been in use as system of support of the photovoltaic installation for allowing it her recharges in the way 2 that more power needs that provided by the photovoltaic installed system. There have been analyzed by means of simulation different rate of load that have been studied experimentally in the realized installation, simultaneously that have done to themselves tests that have reproduced by means of simulation with the same values of solar radiation and temperature in order the model contrasted. The experimental results have been compared by the obtained ones by means of simulation in order to characterize the behavior of the system of accumulation (supplied electric power and tension of exit in the batteries) and of the photovoltaic generator (photovoltaic supplied electric power). Finally, there has been realized an economic study of the autonomous photovoltaic executed and simulated installation. In the same one there has appeared the utilization of own funds (since really it has been carried out) and the utilization of financing, to determine two possible scenes that could be of usefulness to an owner of electrical vehicle. There have been compared the results obtained in both scenes proposed of the economic study of the system, as for the parameters of time of return of the investment, current clear value of the investment and rate hospitalizes of return of the same one. The technical obtained conclusions, they make the utilization of the system viable with the manners of load tested and another type of loads of that they take advantage the electrical generation of the system. The batteries offer better behavior when the photovoltaic contribution is present, but he does not consider to be suitable the connection of loads risen up to a system of accumulation of gel (lead - acid) as the one that has been in use, due to the behavior of this type of batteries before demands of intensity of electrical current raised. On the other hand, the behavior of this type of batteries with low values of intensity of electrical current to 10 To in absence of photovoltaic power, with the aim to use the generation of daily electric power accumulated in the system, yes turns out to be interesting and offers a good behavior of the system of accumulation. The current circumstances of market, which lacks systems of accumulation of lithium with interesting purchase prices, have not allowed to be able to experience this system of accumulation in the autonomous photovoltaic executed installation, neither one could have obtained the favor of any manufacturer for it. Nowadays there are available systems of accumulation in lithium that is not commercialized in Spain and that they would be adapted for the system of accumulation of energy proposed in this study, which makes the doors opened for future works of investigation. The economic obtained conclusions; they make more profitable the use of an autonomous photovoltaic installation with instantaneous consumption, without accumulation of electric power. The future of connection to network on the part of these facilities, when it is regulated, will contribute an economic incentive to make profitable with less time the autonomous photovoltaic facilities, this also leaves the door opened for future works of investigation. The system of accumulation of energy contributes the major economic weight of investment in this type of facilities. The studied installation contributes economic indicators that make her profitable, but it would be necessary that the prices of accumulation of the energy in efficient systems are understood between 100-200 € in order that the system proposed in this work turns out to be attractive to a proprietary potential of an electrical vehicle.
Resumo:
En la última década la potencia instalada de energía solar fotovoltaica ha crecido una media de un 49% anual y se espera que alcance el 16%del consumo energético mundial en el año 2050. La mayor parte de estas instalaciones se corresponden con sistemas conectados a la red eléctrica y un amplio porcentaje de ellas son instalaciones domésticas o en edificios. En el mercado ya existen diferentes arquitecturas para este tipo de instalaciones, entre las que se encuentras los módulos AC. Un módulo AC consiste en un inversor, también conocido como micro-inversor, que se monta en la parte trasera de un panel o módulo fotovoltaico. Esta tecnología ofrece modularidad, redundancia y la extracción de la máxima potencia de cada panel solar de la instalación. Además, la expansión de esta tecnología posibilitará una reducción de costes asociados a las economías de escala y a la posibilidad de que el propio usuario pueda componer su propio sistema. Sin embargo, el micro-inversor debe ser capaz de proporcionar una ganancia de tensión adecuada para conectar el panel solar directamente a la red, mientras mantiene un rendimiento aceptable en un amplio rango de potencias. Asimismo, los estándares de conexión a red deber ser satisfechos y el tamaño y el tiempo de vida del micro-inversor son factores que han de tenerse siempre en cuenta. En esta tesis se propone un micro-inversor derivado de la topología “forward” controlado en el límite entre los modos de conducción continuo y discontinuo (BCM por sus siglas en inglés). El transformador de la topología propuesta mantiene la misma estructura que en el convertidor “forward” clásico y la utilización de interruptores bidireccionales en el secundario permite la conexión directa del inversor a la red. Asimismo el método de control elegido permite obtener factor de potencia cercano a la unidad con una implementación sencilla. En la tesis se presenta el principio de funcionamiento y los principales aspectos del diseño del micro-inversor propuesto. Con la idea de mantener una solución sencilla y de bajo coste, se ha seleccionado un controlador analógico que está originalmente pensado para controlar un corrector del factor de potencia en el mismo modo de conducción que el micro-inversor “forward”. La tesis presenta las principales modificaciones necesarias, con especial atención a la detección del cruce por cero de la corriente (ZCD por sus siglas en inglés) y la compatibilidad del controlador con la inclusión de un algoritmo de búsqueda del punto de máxima potencia (MPPT por sus siglas en inglés). Los resultados experimentales muestran las limitaciones de la implementación elegida e identifican al transformador como el principal contribuyente a las pérdidas del micro-inversor. El principal objetivo de esta tesis es contribuir a la aplicación de técnicas de control y diseño de sistemas multifase en micro-inversores fotovoltaicos. En esta tesis se van a considerar dos configuraciones multifase diferentes aplicadas al micro-inversor “forward” propuesto. La primera consiste en una variación con conexión paralelo-serie que permite la utilización de transformadores con una relación de vueltas baja, y por tanto bien acoplados, para conseguir una ganancia de tensión adecuada con un mejor rendimiento. Esta configuración emplea el mismo control BCM cuando la potencia extraída del panel solar es máxima. Este método de control implica que la frecuencia de conmutación se incrementa considerablemente cuando la potencia decrece, lo que compromete el rendimiento. Por lo tanto y con la intención de mantener unos bueno niveles de rendimiento ponderado, el micro-inversor funciona en modo de conducción discontinuo (DCM, por sus siglas en inglés) cuando la potencia extraía del panel solar es menor que la máxima. La segunda configuración multifase considerada en esta tesis es la aplicación de la técnica de paralelo con entrelazado. Además se han considerado dos técnicas diferentes para decidir el número de fases activas: dependiendo de la potencia continua extraída del panel solar y dependiendo de la potencia instantánea demandada por el micro-inversor. La aplicación de estas técnicas es interesante en los sistemas fotovoltaicos conectados a la red eléctrica por la posibilidad que brindan de obtener un rendimiento prácticamente plano en un amplio rango de potencia. Las configuraciones con entrelazado se controlan en DCM para evitar la necesidad de un control de corriente, lo que es importante cuando el número de fases es alto. Los núcleos adecuados para todas las configuraciones multifase consideradas se seleccionan usando el producto de áreas. Una vez seleccionados los núcleos se ha realizado un diseño detallado de cada uno de los transformadores. Con la información obtenida de los diseños y los resultados de simulación, se puede analizar el impacto que el número de transformadores utilizados tiene en el tamaño y el rendimiento de las distintas configuraciones. Los resultados de este análisis, presentado en esta tesis, se utilizan posteriormente para comparar las distintas configuraciones. Muchas otras topologías se han presentado en la literatura para abordar los diferentes aspectos a considerar en los micro-inversores, que han sido presentados anteriormente. La mayoría de estas topologías utilizan un transformador de alta frecuencia para solventar el salto de tensión y evitar problemas de seguridad y de puesta a tierra. En cualquier caso, es interesante evaluar si topologías sin aislamiento galvánico son aptas para su utilización como micro-inversores. En esta tesis se presenta una revisión de inversores con capacidad de elevar tensión, que se comparan bajo las mismas especificaciones. El objetivo es proporcionar la información necesaria para valorar si estas topologías son aplicables en los módulos AC. Las principales contribuciones de esta tesis son: • La aplicación del control BCM a un convertidor “forward” para obtener un micro-inversor de una etapa sencillo y de bajo coste. • La modificación de dicho micro-inversor con conexión paralelo-series de transformadores que permite reducir la corriente de los semiconductores y una ganancia de tensión adecuada con transformadores altamente acoplados. • La aplicación de técnicas de entrelazado y decisión de apagado de fases en la puesta en paralelo del micro-inversor “forward”. • El análisis y la comparación del efecto en el tamaño y el rendimiento del incremento del número de transformadores en las diferentes configuraciones multifase. • La eliminación de las medidas y los lazos de control de corriente en las topologías multifase con la utilización del modo de conducción discontinuo y un algoritmo MPPT sin necesidad de medida de corriente. • La recopilación y comparación bajo las mismas especificaciones de topologías inversoras con capacidad de elevar tensión, que pueden ser adecuadas para la utilización como micro-inversores. Esta tesis está estructurada en seis capítulos. El capítulo 1 presenta el marco en que se desarrolla la tesis así como el alcance de la misma. En el capítulo 2 se recopilan las topologías existentes de micro-invesores con aislamiento y aquellas sin aislamiento cuya implementación en un módulo AC es factible. Asimismo se presenta la comparación entre estas topologías bajo las mismas especificaciones. El capítulo 3 se centra en el micro-inversor “forward” que se propone originalmente en esta tesis. La aplicación de las técnicas multifase se aborda en los capítulos 4 y 5, en los que se presentan los análisis en función del número de transformadores. El capítulo está orientado a la propuesta paralelo-serie mientras que la configuración con entrelazado se analiza en el capítulo 5. Por último, en el capítulo 6 se presentan las contribuciones de esta tesis y los trabajos futuros. ABSTRACT In the last decade the photovoltaic (PV) installed power increased with an average growth of 49% per year and it is expected to cover the 16% of the global electricity consumption by 2050. Most of the installed PV power corresponds to grid-connected systems, with a significant percentage of residential installations. In these PV systems, the inverter is essential since it is the responsible of transferring into the grid the extracted power from the PV modules. Several architectures have been proposed for grid-connected residential PV systems, including the AC-module technology. An AC-module consists of an inverter, also known as micro-inverter, which is attached to a PV module. The AC-module technology offers modularity, redundancy and individual MPPT of each module. In addition, the expansion of this technology will enable the possibility of economies of scale of mass market and “plug and play” for the user, thus reducing the overall cost of the installation. However, the micro-inverter must be able to provide the required voltage boost to interface a low voltage PV module to the grid while keeping an acceptable efficiency in a wide power range. Furthermore, the quality standards must be satisfied and size and lifetime of the solutions must be always considered. In this thesis a single-stage forward micro-inverter with boundary mode operation is proposed to address the micro-inverter requirements. The transformer in the proposed topology remains as in the classic forward converter and bidirectional switches in the secondary side allows direct connection to the grid. In addition the selected control strategy allows high power factor current with a simple implementation. The operation of the topology is presented and the main design issues are introduced. With the intention to propose a simple and low-cost solution, an analog controller for a PFC operated in boundary mode is utilized. The main necessary modifications are discussed, with the focus on the zero current detection (ZCD) and the compatibility of the controller with a MPPT algorithm. The experimental results show the limitations of the selected analog controller implementation and the transformer is identified as a main losses contributor. The main objective of this thesis is to contribute in the application of control and design multiphase techniques to the PV micro-inverters. Two different multiphase configurations have been applied to the forward micro-inverter proposed in this thesis. The first one consists of a parallel-series connected variation which enables the use of low turns ratio, i.e. well coupled, transformers to achieve a proper voltage boost with an improved performance. This multiphase configuration implements BCM control at maximum load however. With this control method the switching frequency increases significantly for light load operation, thus jeopardizing the efficiency. Therefore, in order to keep acceptable weighted efficiency levels, DCM operation is selected for low power conditions. The second multiphase variation considered in this thesis is the interleaved configuration with two different phase shedding techniques: depending on the DC power extracted from the PV panel, and depending on the demanded instantaneous power. The application of interleaving techniques is interesting in PV grid-connected inverters for the possibility of flat efficiency behavior in a wide power range. The interleaved variations of the proposed forward micro-inverter are operated in DCM to avoid the current loop, which is important when the number of phases is large. The adequate transformer cores for all the multiphase configurations are selected according to the area product parameter and a detailed design of each required transformer is developed. With this information and simulation results, the impact in size and efficiency of the number of transformer used can be assessed. The considered multiphase topologies are compared in this thesis according to the results of the introduced analysis. Several other topological solutions have been proposed to solve the mentioned concerns in AC-module application. The most of these solutions use a high frequency transformer to boost the voltage and avoid grounding and safety issues. However, it is of interest to assess if the non-isolated topologies are suitable for AC-module application. In this thesis a review of transformerless step-up inverters is presented. The compiled topologies are compared using a set benchmark to provide the necessary information to assess whether non-isolated topologies are suitable for AC-module application. The main contributions of this thesis are: • The application of the boundary mode control with constant off-time to a forward converter, to obtain a simple and low-cost single-stage forward micro-inverter. • A modification of the forward micro-inverter with primary-parallel secondary-series connected transformers to reduce the current stress and improve the voltage gain with highly coupled transformers. •The application of the interleaved configuration with different phase shedding strategies to the proposed forward micro-inverter. • An analysis and comparison of the influence in size and efficiency of increasing the number of transformers in the parallel-series and interleaved multiphase configurations. • Elimination of the current loop and current measurements in the multiphase topologies by adopting DCM operation and a current sensorless MPPT. • A compilation and comparison with the same specifications of suitable non-isolated step-up inverters. This thesis is organized in six chapters. In Chapter 1 the background of single-phase PV-connected systems is discussed and the scope of the thesis is defined. Chapter 2 compiles the existing solutions for isolated micro-inverters and transformerless step-up inverters suitable for AC-module application. In addition, the most convenient non-isolated inverters are compared using a defined benchmark. Chapter 3 focuses on the originally proposed single-stage forward micro-inverter. The application of multiphase techniques is addressed in Chapter 4 and Chapter 5, and the impact in different parameters of increasing the number of phases is analyzed. In Chapter 4 an original primary-parallel secondary-series variation of the forward micro-inverter is presented, while Chapter 5 focuses on the application of the interleaved configuration. Finally, Chapter 6 discusses the contributions of the thesis and the future work.
Resumo:
El accidente de pérdida de refrigerante (LOCA) en un reactor nuclear es uno de los accidentes Base de Diseño más preocupantes y estudiados desde el origen del uso de la tecnología de fisión en la industria productora de energía. El LOCA ocupa, desde el punto de vista de los análisis de seguridad, un lugar de vanguardia tanto en el análisis determinista (DSA) como probabilista (PSA), cuya diferenciada perspectiva ha ido evolucionando notablemente en lo que al crédito a la actuación de las salvaguardias y las acciones del operador se refiere. En la presente tesis se aborda el análisis sistemático de de las secuencias de LOCA por pequeña y mediana rotura en diferentes lugares de un reactor nuclear de agua a presión (PWR) con fallo total de Inyección de Seguridad de Alta Presión (HPSI). Tal análisis ha sido desarrollado en base a la metodología de Análisis Integrado de Seguridad (ISA), desarrollado por el Consejo de Seguridad Nuclear (CSN) y consistente en la aplicación de métodos avanzados de simulación y PSA para la obtención de Dominios de Daño, que cuantifican topológicamente las probabilidades de éxito y daño en función de determinados parámetros inciertos. Para la elaboración de la presente tesis, se ha hecho uso del código termohidráulico TRACE v5.0 (patch 2), avalado por la NRC de los EEUU como código de planta para la simulación y análisis de secuencias en reactores de agua ligera (LWR). Los objetivos del trabajo son, principalmente: (1) el análisis exhaustivo de las secuencias de LOCA por pequeña-mediana rotura en diferentes lugares de un PWR de tres lazos de diseño Westinghouse (CN Almaraz), con fallo de HPSI, en función de parámetros de gran importancia para los transitorios, tales como el tamaño de rotura y el tiempo de retraso en la respuesta del operador; (2) la obtención y análisis de los Dominios de Daño para transitorios de LOCA en PWRs, de acuerdo con la metodología ISA; y (3) la revisión de algunos de los resultados genéricos de los análisis de seguridad para secuencias de LOCA en las mencionadas condiciones. Los resultados de la tesis abarcan tres áreas bien diferenciadas a lo largo del trabajo: (a) la fenomenología física de las secuencias objeto de estudio; (b) las conclusiones de los análisis de seguridad practicados a los transitorios de LOCA; y (c) la relevancia de las consecuencias de las acciones humanas por parte del grupo de operación. Estos resultados, a su vez, son de dos tipos fundamentales: (1) de respaldo del conocimiento previo sobre el tipo de secuencias analizado, incluido en la extensa bibliografía examinada; y (2) hallazgos en cada una de las tres áreas mencionadas, no referidos en la bibliografía. En resumidas cuentas, los resultados de la tesis avalan el uso de la metodología ISA como método de análisis alternativo y sistemático para secuencias accidentales en LWRs. ABSTRACT The loss of coolant accident (LOCA) in nuclear reactors is one of the most concerning and analized accidents from the beginning of the use of fission technology for electric power production. From the point of view of safety analyses, LOCA holds a forefront place in both Deterministic (DSA) and Probabilistic Safety Analysis (PSA), which have significantly evolved from their original state in both safeguard performance credibility and human actuation. This thesis addresses a systematic analysis of small and medium LOCA sequences, in different places of a nuclear Pressurized Water Reactor (PWR) and with total failure of High Pressure Safety Injection (HPSI). Such an analysis has been grounded on the Integrated Safety Assessment (ISA) methodology, developed by the Spanish Nuclear Regulatory Body (CSN). ISA involves the application of advanced methods of simulation and PSA for obtaining Damage Domains that topologically quantify the likelihood of success and damage regarding certain uncertain parameters.TRACE v5.0 (patch 2) code has been used as the thermalhydraulic simulation tool for the elaboration of this work. Nowadays, TRACE is supported by the US NRC as a plant code for the simulation and analysis of sequences in light water reactors (LWR). The main objectives of the work are the following ones: (1) the in-depth analysis of small and medium LOCA sequences in different places of a Westinghouse three-loop PWR (Almaraz NPP), with failed HPSI, regarding important parameters, such as break size or delay in operator response; (2) obtainment and analysis of Damage Domains related to LOCA transients in PWRs, according to ISA methodology; and (3) review some of the results of generic safety analyses for LOCA sequences in those conditions. The results of the thesis cover three separated areas: (a) the physical phenomenology of the sequences under study; (b) the conclusions of LOCA safety analyses; and (c) the importance of consequences of human actions by the operating crew. These results, in turn, are of two main types: (1) endorsement of previous knowledge about this kind of sequences, which is included in the literature; and (2) findings in each of the three aforementioned areas, not reported in the reviewed literature. In short, the results of this thesis support the use of ISA-like methodology as an alternative method for systematic analysis of LWR accidental sequences.
Resumo:
This paper presents a work whose objective is, first, to quantify the potential of the triticale biomass existing in each of the agricultural regions in the Madrid Community through a crop simulation model based on regression techniques and multiple correlation. Second, a methodology for defining which area has the best conditions for the installation of electricity plants from biomass has been described and applied. The study used a methodology based on compromise programming in a discrete multicriteria decision method (MDM) context. To make a ranking, the following criteria were taken into account: biomass potential, electric power infrastructure, road networks, protected spaces, and urban nuclei surfaces. The results indicate that, in the case of the Madrid Community, the Campiña region is the most suitable for setting up plants powered by biomass. A minimum of 17,339.9 tons of triticale will be needed to satisfy the requirements of a 2.2 MW power plant. The minimum range of action for obtaining the biomass necessary in Campiña region would be 6.6 km around the municipality of Algete, based on Geographic Information Systems. The total biomass which could be made available in considering this range in this region would be 18,430.68 t.
Resumo:
Ocean energy is a promising resource for renewable electricity generation that presents many advantages, such as being more predictable than wind energy, but also some disadvantages such as large and slow amplitude variations in the generated power. This paper presents a hardware-in-the-loop prototype that allows the study of the electric power profile generated by a wave power plant based on the oscillating water column (OWC) principle. In particular, it facilitates the development of new solutions to improve the intermittent profile of the power fed into the grid or the test of the OWC behavior when facing a voltage dip. Also, to obtain a more realistic model behavior, statistical models of real waves have been implemented.
Resumo:
This paper presents a primary-parallel secondaryseries multicore forward microinverter for photovoltaic ac-module application. The presented microinverter operates with a constant off-time boundary mode control, providing MPPT capability and unity power factor. The proposed multitransformer solution allows using low-profile unitary turns ratio transformers. Therefore, the transformers are better coupled and the overall performance of the microinverter is improved. Due to the multiphase solution, the number of devices increases but the current stress and losses per device are reduced contributing to an easier thermal management. Furthermore, the decoupling capacitor is split among the phases, contributing to a low-profile solution without electrolytic capacitors suitable to be mounted in the frame of a PV module. The proposed solution is compared to the classical parallel-interleaved approach, showing better efficiency in a wide power range and improving the weighted efficiency.
Resumo:
Synchronous machines with brushless excitation have the disadvantage that the field winding is not accessible for the de-excitation of the machine. This means that, despite the proper operation of the protection system, the slow de-excitation time constant may produce severe damage in the event of an internal short circuit. A high-speed de-excitation system for these machines was developed, and this study presents the continuation of a previously published study. This study presents the design by computer simulation and the results of the first commissioning of this de-excitation system in a commercial 20 MVA hydro-generator. The de-excitation is achieved by inserting resistance in the field circuit, obtaining a dynamic response similar to that achieved in machines with static excitation. In this case, a non-linear discharge resistor was used, making the dynamic response even better.