968 resultados para Drainage Sewage
Resumo:
Newsletter for Department of Natural Resources, Waste Management Division
Resumo:
Newsletter produced by Department Natural Resources, Waste Managment Division
Resumo:
Newsletter prdouced by Department of Natural Resources, Waste Matters Division
Resumo:
Newsletter produced by Department of Natural Resources, Waste Management Division
Resumo:
Il s'agit de comparer in vivo la sécurité et l'efficacité d'un implant en polyméthylméthacrylate (PMMA) avec un implant standard en collagène dans la sclérectomie profonde (SP) sur une durée de six mois. La population étudiée comprend vingt lapins, chaque lapin étant randomisé pour une SP avec implant en PMMA dans un oeil et implant de collagène dans l'autre oeil. Plusieurs éléments ont été pris en compte dans la comparaison : - la mesure de la pression intraoculaire - l'évolution de l'espace de drainage intrascléral et de la bulle de filtration sous-conjonctivale, suivie par ultrasonographic biomicroscopique (UBM) - la croissance de nouveaux vaisseaux de drainage sous-conjonctivaux, croissance quantifiée par angiographie du segment antérieur à la fluorescéine combinée au vert d'indocyanine - la facilité à l'écoulement de l'humeur aqueuse (C), mesurée à six mois par cannulation-perfusion de la chambre antérieur - la sclère au site de SP, histologiquement comparée à la sclère native opposée à 180°, également à six mois La pression intraoculaire moyenne préopératoire à une, quatre, douze et 24 semaines postopératoires est comparable dans les deux groupes (P>0.1). L'UBM montre une régression légèrement plus rapide (statistiquement non significative) de la bulle de filtration sous-conjonctivale et la persistance d'un espace de drainage intrascléral dans le groupe PMMA (P>0.05). De nouveaux vaisseaux de drainage sont observés à un mois de la chirurgie ; à six mois, ces vaisseaux sont plus nombreux dans le groupe PMMA, tant sur l'analyse angiographique que sur l'analyse histologique (P>0.05). La facilité moyenne à l'écoulement de l'humeur aqueuse est significativement plus élevées à six mois dans les deux groupes par rapport aux valeurs préopératoires (P>0.05), sans qu'il n'y ait de différence entre les deux implants (0.24 ± 0.06 μΙ/min/mmHg [PMMA] et 0.23 ± 0.07 μΙ/min/mmHg [implant en collagène]) (Ρ = 0.39). Cette étude a pu démontrer que la sclérectomie profonde avec implant en collagène ou en PMMA donne des résultats similaires en terme de diminution de l'IOP et d'augmentation de la facilité à l'écoulement de l'humeur aqueuse, sans différence sur le plan des réactions inflammatoires post-intervention.
Resumo:
Background: The purpose of this study is to report the anatomic and functional results of primary 23 G vitrectomy using slit-lamp and non-contact 90 D lens for the treatment of pseudophakic rhegmatogenous retinal detachment. Patients and Methods: Pseudophakic eyes were operated by 23 G vitrectomy using slit-lamp and non-contact 90 D lens, internal subretinal fluid drainage, cryopexy and internal gas tamponade. The preoperative and postoperative characteristics were analysed. Main outcome measures were anatomic success rates after initial surgical intervention and after reoperation for primary failures, visual outcome at the last follow-up visit, and complications. Results: 46 pseudophakic eyes were included in this retrospective study (October 2013- January 2014). In 40 cases, sulfur hexafluoride 23 % gastamponade was used, silicone oil in 6 cases (13 %). The retina was reattached successfully after a single surgery in 44 eyes (96 %). Recurrence of retinal detachment occurred in 2 eyes. Final anatomic reattachment was obtained in 100 % after a second operation. Silicone oil was removed in all eyes. Visual acuity improved significantly from logMAR 0 (IQR 0 - 0.9) to logMAR 0 (IQR 0 - 0.2) (p < 0.005). Conclusions: Primary 23 G vitrectomy using slit-lamp and non contact 90 D lens for the treatment of pseudophakic rhegmatogenous retinal detachment provides a high anatomic and functional success rate and is associated with few complications.
Resumo:
OBJECTIVE: Transthoracic echocardiography (TTE) has been used clinically to disobstruct venous drainage cannula and to optimise placement of venous cannulae in the vena cava but it has never been used to evaluate performance capabilities. Also, little progress has been made in venous cannula design in order to optimise venous return to the heart lung machine. We designed a self-expandable Smartcanula (SC) and analysed its performance capability using echocardiography. METHODS: An epicardial echocardiography probe was placed over the SC or control cannula (CTRL) and a Doppler image was obtained. Mean (V(m)) and maximum (V(max)) velocities, flow and diameter were obtained. Also, pressure drop (DeltaP(CPB)) was obtained between the central venous pressure and inlet to venous reservoir. LDH and Free Hb were also compared in 30 patients. Comparison was made between the two groups using the student's t-test with statistical significance established when p<0.05. RESULTS: Age for the SC and CC groups were 61.6+/-17.6 years and 64.6+/-13.1 years, respectively. Weight was 70.3+/-11.6 kg and 72.8+/-14.4 kg, respectively. BSA was 1.80+/-0.2 m(2) and 1.82+/-0.2 m(2), respectively. CPB times were 114+/-53 min and 108+/-44 min, respectively. Cross-clamp time was 59+/-15 min and 76+/-29 min, respectively (p=NS). Free-Hb was 568+/-142 U/l versus 549+/-271 U/l post-CPB for the SC and CC, respectively (p=NS). LDH was 335+/-73 mg/l versus 354+/-116 mg/l for the SC and CC, respectively (p=NS). V(m) was 89+/-10 cm/s (SC) versus 63+/-3 cm/s (CC), V(max) was 139+/-23 cm/s (SC) versus 93+/-11 cm/s (CC) (both p<0.01). DeltaP(CPB) was 30+/-10 mmHg (SC) versus 43+/-13 mmHg (CC) (p<0.05). A Bland-Altman test showed good agreement between the two devices used concerning flow rate calculations between CPB and TTE (bias 300 ml+/-700 ml standard deviation). CONCLUSIONS: This novel Smartcanula design, due to its self-expanding principle, provides superior flow characteristics compared to classic two stage venous cannula used for adult CPB surgery. No detrimental effects were observed concerning blood damage. Echocardiography was effective in analysing venous cannula performance and velocity patterns.
Resumo:
Bridge approach settlement and the formation of the bump is a common problem in Iowa that draws upon considerable resources for maintenance and creates a negative perception in the minds of transportation users. This research study was undertaken to investigate bridge approach problems and develop new concepts for design, construction, and maintenance that will reduce this costly problem. As a result of the research described in this report, the following changes are suggested for implementation on a pilot test basis: • Use porous backfill behind the abutment and/or geocomposite drainage systems to improve drainage capacity and reduce erosion around the abutment. • On a pilot basis, connect the approach slab to the bridge abutment. Change the expansion joint at the bridge to a construction joint of 2 inch. Use a more effective joint sealing system at the CF joint. Change the abutment wall rebar from #5 to #7 for non-integral abutments. • For bridges with soft foundation or embankment soils, implement practices of better compaction, preloading, ground improvement, soil removal and replacement, or soil reinforcement that reduce time-dependent post construction settlements.