990 resultados para DIODE INTERFEROMETER


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe the results of in-vivo trials of a portable fiber Bragg grating based temperature profile monitoring system. The probe incorporates five Bragg gratings along a single fiber and prevents the gratings from being strained. Illumination is provided by a superluminescent diode, and a miniature CCD based spectrometer is used for demultiplexing. The CCD signal is read into a portable computer through a small A/D interface; the computer then calculates the positions of the center wavelengths of the Bragg gratings, providing a resolution of 0.2°C. Tests were carried out on rabbits undergoing hyperthermia treatment of the kidney and liver via inductive heating of metallic implants and comparison was made with a commercial Fluoroptic thermometry system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis presents details on progress made in the fabrication and application of short and novel structure fibre Bragg gratings. The basic theoretical concepts of in-fibre Bragg gratings and photosensitive mechanisms are introduced together with an overview of fabrication methods and applications presented to date. The fabrication of fibre Bragg gratings using a quadrupled Nd:YAG laser is presented and some of the issues of grating fabrication using a fabrication using a phasemask are investigated, including the variation of the separation of the fibre and phasemask, and other alignment issues. A new apodisation technique is presented, enabling the production of gratings with a wide range of spectral profiles. The technique is used to investigate the design and fabrication of length limited fibre Bragg gratings for use in telecommunication systems as filters. Application to devices designed for use in WDM systems is presented. The use of fibre Bragg gratings as high spatial resolution distributed sensors is investigated. Grating sensing arrays comprising very short apodised gratings are demonstrated and Chirped Moiré gratings are implemented as distributed sensors achieving high spatial resolution with miniature point sensing sub-elements. A novel grating sensing element designed to imitate an interferometer is also presented. Finally, the behaviour of gratings fabricated in Boron-Germania-co-doped fibre is investigated, revealing atypical behaviour of the Bragg wavelength during ageing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The underlying work to this thesis focused on the exploitation and investigation of photosensitivity mechanisms in optical fibres and planar waveguides for the fabrication of advanced integrated optical devices for telecoms and sensing applications. One major scope is the improvement of grating fabrication specifications by introducing new writing techniques and the use of advanced characterisation methods for grating testing. For the first time the polarisation control method for advanced grating fabrication has successfully been converted to apodised planar waveguide fabrication and the development of a holographic method for the inscription of chirped gratings at arbitrary wavelength is presented. The latter resulted in the fabrication of gratings for pulse-width suppression and wavelength selection in diode lasers. In co-operation with research partners a number of samples were tested using optical frequency domain and optical low coherence reflectometry for a better insight into the limitations of grating writing techniques. Using a variety of different fabrication methods, custom apodised and chirped fibre Bragg gratings were written for the use as filter elements for multiplexer-demultiplexer devices, as well as for short pulse generation and wavelength selection in telecommunication transmission systems. Long period grating based devices in standard, speciality and tapered fibres are presented, showing great potential for multi-parameter sensing. One particular scope is the development of vectorial curvature and refractive index sensors with potential for medical, chemical and biological sensing. In addition the design of an optically tunable Mach-Zehnder based multiwavelength filter is introduced. The discovery of a Type IA grating type through overexposure of hydrogen loaded standard and Boron-Germanium co-doped fibres strengthened the assumption of UV-photosensitivity being a highly non-linear process. Gratings of this type show a significantly lower thermal sensitivity compared to standard gratings, which makes them useful for sensing applications. An Oxford Lasers copper-vapour laser operating at 255 nm in pulsed mode was used for their inscription, in contrast to previous work using CW-Argon-Ion lasers and contributing to differences in the processes of the photorefractive index change

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the research work described in this thesis was to investigate the interrogation of fibre optic sensors using "off the shelf optical components and equipment developed mainly for the telecommunications industry. This provides a cost effective way of bringing fibre optic sensor systems to within the price range of their electro-mechanical counterparts. The research work focuses on the use of an arrayed waveguide grating, an acousto-optic tuneable filter and low-coherence interferometry to measure dynamic strain and displacement using fibre Bragg grating and interferometric sensors. Based on the intrinsic properties of arrayed waveguide gratings and acousto-optic tuneable filters used in conjunction with interferometry, fibre Bragg gratings and interferometric sensors a number of novel fibre optic sensor interrogation systems have been realised. Special single mode fibre, namely, high-birefringence fibre has been employed to implement a dual-beam interrogating interferometer. The first interrogation scheme is based on an optical channel monitor, which is an arrayed waveguide grating with integral photo-detectors providing a number of amplified electrical outputs. It is used to interrogate fibre Bragg grating and interferometric sensors. Using the properties of polarisation maintainability in high-birefringent fibre an interrogating interferometer was realised by winding a length of the fibre around a piezoelectric modulator generating a low-frequency carrier signal. The system was used to interrogate both fibre Bragg grating and interferometric sensors. Finally, the use of an acousto-optic tuneable filter is employed to interrogate fibre Bragg gratings. The device is used to generate a very high frequency carrier signal at the output of an optical interferometer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two-way power flow is nothing new and has been in practical use using line commutated converters for at least 50 years. With these types of converters, reversal of power flow can be achieved by increasing the firing angle of the devices beyond 90 degrees thus producing a negative DC voltage. Line commutated converters have several known disadvantages including: the direct current cannot be reversed, the power factor decreases when the firing angle increases and the harmonics are high on the line current. To tackle the above problems a forced commutated converter can be used. The power factor can be unity and the harmonics can be reduced. Many researchers have used PWM with different control techniques to serve the above purposes. In each converter arm, they used a forced commutated device with an antiparallel diode. Under the rectification mode of operation the current path is preponderantly through the diodes and under the inverter operation the current flows preponderantly through the forced commutated devices. Although their results were encouraging and gave a unity power factor with nearly sinusoidal current, the main disadvantage was that there were difficulties in controlling the power factor when the system is needed to operate at lagging or leading power factor. In this work, a new idea was introduced by connecting two GTOs antiparallel instead of a diode and a GTO. A single phase system using two GTO converters which are connected in series was built. One converter operates as a rectifier and the other converter operates as an inverter. In the case of the inversion mode and in each inverter arm one GTO is operated as a diode simply by switching it always on and the other antiparallel GTO is operated as a normal device to carry the inverter current. In case of the rectification mode, in each arm one GTO is always off and the other GTP is operated as a controlled device. The main advantage is that the system can be operated at lagging or leading power factor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigate the feasibility of simultaneous suppressing of the amplification noise and nonlinearity, representing the most fundamental limiting factors in modern optical communication. To accomplish this task we developed a general design optimisation technique, based on concepts of noise and nonlinearity management. We demonstrate the immense efficiency of the novel approach by applying it to a design optimisation of transmission lines with periodic dispersion compensation using Raman and hybrid Raman-EDFA amplification. Moreover, we showed, using nonlinearity management considerations, that the optimal performance in high bit-rate dispersion managed fibre systems with hybrid amplification is achieved for a certain amplifier spacing – which is different from commonly known optimal noise performance corresponding to fully distributed amplification. Required for an accurate estimation of the bit error rate, the complete knowledge of signal statistics is crucial for modern transmission links with strong inherent nonlinearity. Therefore, we implemented the advanced multicanonical Monte Carlo (MMC) method, acknowledged for its efficiency in estimating distribution tails. We have accurately computed acknowledged for its efficiency in estimating distribution tails. We have accurately computed marginal probability density functions for soliton parameters, by numerical modelling of Fokker-Plank equation applying the MMC simulation technique. Moreover, applying a powerful MMC method we have studied the BER penalty caused by deviations from the optimal decision level in systems employing in-line 2R optical regeneration. We have demonstrated that in such systems the analytical linear approximation that makes a better fit in the central part of the regenerator nonlinear transfer function produces more accurate approximation of the BER and BER penalty. We present a statistical analysis of RZ-DPSK optical signal at direct detection receiver with Mach-Zehnder interferometer demodulation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An astigmatic scheme of a laser wavelength meter based on a single air-gap Fizeau interferometer is described. For a multimode laser, the accuracy in determining the center of gravity of a spectrum is within 1GHz. Two complementary testing techniques are proposed for the instrument. By using them, it was shown for the first time that, for this type of meters, a systematic error arises and increases with a decrease in the radiation-spectrum width. The effect is periodic in the lasing frequency and results from a weak beam that is brought about by a reflection from the front surface of the interferometer. Moreover, in the previously designed optical schemes, this effect is so strong that unambiguous determination of the wavelength of a single-frequency radiation is impossible. The use of an astigmatic scheme helps additionally attenuate the influence of the third beam, thus eliminating the ambiguity in the results and reducing the absolute error to a value of ±1.5 GHz.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have experimentally investigated two non-inverting optical memory configurations: a TOAD based device & an integrated hybrid Mach-Zehnder interferometer. Experimental results for both devices and a comparison of the two techniques is presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe the results of in-vivo trials of a portable fiber Bragg grating based temperature profile monitoring system. The probe incorporates five Bragg gratings along a single fiber and prevents the gratings from being strained. Illumination is provided by a superluminescent diode, and a miniature CCD based spectrometer is used for demultiplexing. The CCD signal is read into a portable computer through a small A/D interface; the computer then calculates the positions of the center wavelengths of the Bragg gratings, providing a resolution of 0.2 °C. Tests were carried out on rabbits undergoing hyperthermia treatment of the kidney and liver via inductive heating of metallic implants and comparison was made with a commercial Fluoroptic thermometry system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Some critical aspects of a new kind of on-line measurement technique for micro and nanoscale surface measurements are described. This attempts to use spatial light-wave scanning to replace mechanical stylus scanning, and an optical fibre interferometer to replace optically bulky interferometers for measuring the surfaces. The basic principle is based on measuring the phase shift of a reflected optical signal. Wavelength-division-multiplexing and fibre Bragg grating techniques are used to carry out wavelength-to-field transformation and phase-to-depth detection, allowing a large dynamic measurement ratio (range/resolution) and high signal-to-noise ratio with remote access. In effect the paper consists of two parts: multiplexed fibre interferometry and remote on-machine surface detection sensor (an optical dispersive probe). This paper aims to investigate the metrology properties of a multiplexed fibre interferometer and to verify its feasibility by both theoretical and experimental studies. Two types of optical probes, using a dispersive prism and a blazed grating, respectively, are introduced to realize wavelength-to-spatial scanning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We show that with a fiberized multiple Michelson-interferometer-type configuration, transverse images from several layers in the human eye can be simultaneously obtained. We demonstrate the principle by producing simultaneous 100×100 pixel en-face images of a 4 mm×4 mm region on a postmortem retina for two depth positions 250 µm apart.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe a configuration consisting of two fiberised Michelson interferometers and show that, with an optical balanced technique and suitable electronics, the signal corresponding to coherent interference in the first interferometer can be sufficiently attenuated in the channel processing the signal from the second interferometer. In this way it is possible to display simultaneous reflectograms of two different regions in the eye (e.g. cornea and retina) and infer the eye length from these measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We show that, with suitable optics in the arm of a Michelson interferometer, orthogonal galvo-scanning mirrors build a sampling function in the form of Newton rings when the two interferometer arms are matched. Using a low-coherence source, one can obtain transversal depth-resolved images. A fast display procedure using a storage oscilloscope was devised based on this method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We propose a new method for the simultaneous interrogation of conventional two-beam interferometers and Bragg grating sensors. The technique employs an unbalanced Mach-Zehnder interferometer illuminated by a single low-coherence source, which acts as a wavelength-tunable source for the grating and as a path-matched f ilter for the Fizeau interferometer, thus providing a high phase resolution output for each sensor. The grating sensor demonstrates a dynamic strain resolution of ~0.05 µe/vHz at 20 Hz, while the interferometric phase resolution is better than 1 mrad/vHz at 20 Hz, corresponding to an rms mirror displacement of 0.08 nm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The channelled spectrum of an optical beam generated by a laser diode operated below threshold after traversing microscope glass plates is spectrally analysed using a grating and a CCD linear array. The experiment has the following goals: to display the resulting channelled spectrum, to familiarize students with an important topic in metrology and to illustrate some interesting topics from spectroscopy using a CCD array as a spectrometer.