986 resultados para Continuous Monitoring


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In Europe, Cardiovascular Diseases (CVD) are the leading source of death, causing 45% of all deceases. Besides, Heart Failure, the paradigm of CVD, mainly affects people older than 65. In the current aging society, the European MyHeart Project was created, whose mission is to empower citizens to fight CVD by leading a preventive lifestyle and being able to be diagnosed at an early stage. This paper presents the development of a Heart Failure Management System, based on daily monitoring of Vital Body Signals, with wearable and mobile technologies, for the continuous assessment of this chronic disease. The System makes use of the latest technologies for monitoring heart condition, both with wearable garments (e.g. for measuring ECG and Respiration); and portable devices (such as Weight Scale and Blood Pressure Cuff) both with Bluetooth capabilities

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Esta tesis estudia la monitorización y gestión de la Calidad de Experiencia (QoE) en los servicios de distribución de vídeo sobre IP. Aborda el problema de cómo prevenir, detectar, medir y reaccionar a las degradaciones de la QoE desde la perspectiva de un proveedor de servicios: la solución debe ser escalable para una red IP extensa que entregue flujos individuales a miles de usuarios simultáneamente. La solución de monitorización propuesta se ha denominado QuEM(Qualitative Experience Monitoring, o Monitorización Cualitativa de la Experiencia). Se basa en la detección de las degradaciones de la calidad de servicio de red (pérdidas de paquetes, disminuciones abruptas del ancho de banda...) e inferir de cada una una descripción cualitativa de su efecto en la Calidad de Experiencia percibida (silencios, defectos en el vídeo...). Este análisis se apoya en la información de transporte y de la capa de abstracción de red de los flujos codificados, y permite caracterizar los defectos más relevantes que se observan en este tipo de servicios: congelaciones, efecto de “cuadros”, silencios, pérdida de calidad del vídeo, retardos e interrupciones en el servicio. Los resultados se han validado mediante pruebas de calidad subjetiva. La metodología usada en esas pruebas se ha desarrollado a su vez para imitar lo más posible las condiciones de visualización de un usuario de este tipo de servicios: los defectos que se evalúan se introducen de forma aleatoria en medio de una secuencia de vídeo continua. Se han propuesto también algunas aplicaciones basadas en la solución de monitorización: un sistema de protección desigual frente a errores que ofrece más protección a las partes del vídeo más sensibles a pérdidas, una solución para minimizar el impacto de la interrupción de la descarga de segmentos de Streaming Adaptativo sobre HTTP, y un sistema de cifrado selectivo que encripta únicamente las partes del vídeo más sensibles. También se ha presentado una solución de cambio rápido de canal, así como el análisis de la aplicabilidad de los resultados anteriores a un escenario de vídeo en 3D. ABSTRACT This thesis proposes a comprehensive approach to the monitoring and management of Quality of Experience (QoE) in multimedia delivery services over IP. It addresses the problem of preventing, detecting, measuring, and reacting to QoE degradations, under the constraints of a service provider: the solution must scale for a wide IP network delivering individual media streams to thousands of users. The solution proposed for the monitoring is called QuEM (Qualitative Experience Monitoring). It is based on the detection of degradations in the network Quality of Service (packet losses, bandwidth drops...) and the mapping of each degradation event to a qualitative description of its effect in the perceived Quality of Experience (audio mutes, video artifacts...). This mapping is based on the analysis of the transport and Network Abstraction Layer information of the coded stream, and allows a good characterization of the most relevant defects that exist in this kind of services: screen freezing, macroblocking, audio mutes, video quality drops, delay issues, and service outages. The results have been validated by subjective quality assessment tests. The methodology used for those test has also been designed to mimic as much as possible the conditions of a real user of those services: the impairments to evaluate are introduced randomly in the middle of a continuous video stream. Based on the monitoring solution, several applications have been proposed as well: an unequal error protection system which provides higher protection to the parts of the stream which are more critical for the QoE, a solution which applies the same principles to minimize the impact of incomplete segment downloads in HTTP Adaptive Streaming, and a selective scrambling algorithm which ciphers only the most sensitive parts of the media stream. A fast channel change application is also presented, as well as a discussion about how to apply the previous results and concepts in a 3D video scenario.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper summarizes the experience and the lessons learned from the European project PERFORM (A sophisticated multi-parametric system FOR the continuous effective assessment and monitoring of motor status in Parkinson's disease and other neurodegenerative diseases). PERFORM is aimed to provide a telehealth system for the remote monitoring of Parkinson's disease patients (PD) at their homes. This paper explains the global experience with PERFORM. It summarizes the technical performance of the system and the feedback received from the patients in terms of usability and wearability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper summarizes the experience and the lessons learned from the European project PERFORM (A sophisticated multi-parametric system FOR the continuous effective assessment and monitoring of motor status in Parkinson s disease and other neurodegenerative diseases). PERFORM is aimed to provide a telehealth system for the remote monitoring of Parkinson s disease patients (PD) at their homes. This paper explains the global experience with PERFORM. It summarizes the technical performance of the system and the feedback received from the patients in terms of usability and wearability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La gestión de los residuos radiactivos de vida larga producidos en los reactores nucleares constituye uno de los principales desafíos de la tecnología nuclear en la actualidad. Una posible opción para su gestión es la transmutación de los nucleidos de vida larga en otros de vida más corta. Los sistemas subcríticos guiados por acelerador (ADS por sus siglas en inglés) son una de las tecnologías en desarrollo para logar este objetivo. Un ADS consiste en un reactor nuclear subcrítico mantenido en un estado estacionario mediante una fuente externa de neutrones guiada por un acelerador de partículas. El interés de estos sistemas radica en su capacidad para ser cargados con combustibles que tengan contenidos de actínidos minoritarios mayores que los reactores críticos convencionales, y de esta manera, incrementar las tasas de trasmutación de estos elementos, que son los principales responsables de la radiotoxicidad a largo plazo de los residuos nucleares. Uno de los puntos clave que han sido identificados para la operación de un ADS a escala industrial es la necesidad de monitorizar continuamente la reactividad del sistema subcrítico durante la operación. Por esta razón, desde los años 1990 se han realizado varios experimentos en conjuntos subcríticos de potencia cero (MUSE, RACE, KUCA, Yalina, GUINEVERE/FREYA) con el fin de validar experimentalmente estas técnicas. En este contexto, la presente tesis se ocupa de la validación de técnicas de monitorización de la reactividad en el conjunto subcrítico Yalina-Booster. Este conjunto pertenece al Joint Institute for Power and Nuclear Research (JIPNR-Sosny) de la Academia Nacional de Ciencias de Bielorrusia. Dentro del proyecto EUROTRANS del 6º Programa Marco de la UE, en el año 2008 se ha realizado una serie de experimentos en esta instalación concernientes a la monitorización de la reactividad bajo la dirección del CIEMAT. Se han realizado dos tipos de experimentos: experimentos con una fuente de neutrones pulsada (PNS) y experimentos con una fuente continua con interrupciones cortas (beam trips). En el caso de los primeros, experimentos con fuente pulsada, existen dos técnicas fundamentales para medir la reactividad, conocidas como la técnica del ratio bajo las áreas de los neutrones inmediatos y retardados (o técnica de Sjöstrand) y la técnica de la constante de decaimiento de los neutrones inmediatos. Sin embargo, varios experimentos han mostrado la necesidad de aplicar técnicas de corrección para tener en cuenta los efectos espaciales y energéticos presentes en un sistema real y obtener valores precisos de la reactividad. En esta tesis, se han investigado estas correcciones mediante simulaciones del sistema con el código de Montecarlo MCNPX. Esta investigación ha servido también para proponer una versión generalizada de estas técnicas donde se buscan relaciones entre la reactividad el sistema y las cantidades medidas a través de simulaciones de Monte Carlo. El segundo tipo de experimentos, experimentos con una fuente continua e interrupciones del haz, es más probable que sea empleado en un ADS industrial. La versión generalizada de las técnicas desarrolladas para los experimentos con fuente pulsada también ha sido aplicada a los resultados de estos experimentos. Además, el trabajo presentado en esta tesis es la primera vez, en mi conocimiento, en que la reactividad de un sistema subcrítico se monitoriza durante la operación con tres técnicas simultáneas: la técnica de la relación entre la corriente y el flujo (current-to-flux), la técnica de desconexión rápida de la fuente (source-jerk) y la técnica del decaimiento de los neutrones inmediatos. Los casos analizados incluyen la variación rápida de la reactividad del sistema (inserción y extracción de las barras de control) y la variación rápida de la fuente de neutrones (interrupción larga del haz y posterior recuperación). ABSTRACT The management of long-lived radioactive wastes produced by nuclear reactors constitutes one of the main challenges of nuclear technology nowadays. A possible option for its management consists in the transmutation of long lived nuclides into shorter lived ones. Accelerator Driven Subcritical Systems (ADS) are one of the technologies in development to achieve this goal. An ADS consists in a subcritical nuclear reactor maintained in a steady state by an external neutron source driven by a particle accelerator. The interest of these systems lays on its capacity to be loaded with fuels having larger contents of minor actinides than conventional critical reactors, and in this way, increasing the transmutation rates of these elements, that are the main responsible of the long-term radiotoxicity of nuclear waste. One of the key points that have been identified for the operation of an industrial-scale ADS is the need of continuously monitoring the reactivity of the subcritical system during operation. For this reason, since the 1990s a number of experiments have been conducted in zero-power subcritical assemblies (MUSE, RACE, KUCA, Yalina, GUINEVERE/FREYA) in order to experimentally validate these techniques. In this context, the present thesis is concerned with the validation of reactivity monitoring techniques at the Yalina-Booster subcritical assembly. This assembly belongs to the Joint Institute for Power and Nuclear Research (JIPNR-Sosny) of the National Academy of Sciences of Belarus. Experiments concerning reactivity monitoring have been performed in this facility under the EUROTRANS project of the 6th EU Framework Program in year 2008 under the direction of CIEMAT. Two types of experiments have been carried out: experiments with a pulsed neutron source (PNS) and experiments with a continuous source with short interruptions (beam trips). For the case of the first ones, PNS experiments, two fundamental techniques exist to measure the reactivity, known as the prompt-to-delayed neutron area-ratio technique (or Sjöstrand technique) and the prompt neutron decay constant technique. However, previous experiments have shown the need to apply correction techniques to take into account the spatial and energy effects present in a real system and thus obtain accurate values for the reactivity. In this thesis, these corrections have been investigated through simulations of the system with the Monte Carlo code MCNPX. This research has also served to propose a generalized version of these techniques where relationships between the reactivity of the system and the measured quantities are obtained through Monte Carlo simulations. The second type of experiments, with a continuous source with beam trips, is more likely to be employed in an industrial ADS. The generalized version of the techniques developed for the PNS experiments has also been applied to the result of these experiments. Furthermore, the work presented in this thesis is the first time, to my knowledge, that the reactivity of a subcritical system has been monitored during operation simultaneously with three different techniques: the current-to-flux, the source-jerk and the prompt neutron decay techniques. The cases analyzed include the fast variation of the system reactivity (insertion and extraction of a control rod) and the fast variation of the neutron source (long beam interruption and subsequent recovery).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays, the intensive use of Technology Information (TI) provide solutions to problems of the high population density, energy conservation and cities management. This produces a newest concept of the city, Smart City. But the inclusion of TI in the city brings associated new problems, specifically the generation of electromagnetic fields from the available and new technological infrastructures installed in the city that did not exist before. This new scenario produces a negative effect on a particular group of the society, as are the group of persons with electromagnetic hypersensitivity pathology. In this work we propose a system that would allow you to detect and prevent the continuous exposure to such electromagnetic fields, without the need to include more devices or infrastructure which would only worsen these effects. Through the use of the architecture itself and Smart City services, it is possible to infer the necessary knowledge to know the situation of the EMF radiation and thus allow users to avoid the areas of greatest conflict. This knowledge, not only allows us to get EMF current map of the city, but also allows you to generate predictions and detect future risk situations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A MATLAB-based computer code has been developed for the simultaneous wavelet analysis and filtering of several environmental time series, particularly focused on the analyses of cave monitoring data. The continuous wavelet transform, the discrete wavelet transform and the discrete wavelet packet transform have been implemented to provide a fast and precise time–period examination of the time series at different period bands. Moreover, statistic methods to examine the relation between two signals have been included. Finally, the entropy of curves and splines based methods have also been developed for segmenting and modeling the analyzed time series. All these methods together provide a user-friendly and fast program for the environmental signal analysis, with useful, practical and understandable results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A detector based on doped silica and optical fibers was developed to monitor the profile of particle accelerator beams of intensity ranging from 1 pA to tens of µA. Scintillation light produced in a fiber moving across the beam is measured, giving information on its position, shape and intensity. The detector was tested with a continuous proton beam at the 18 MeV Bern medical cyclotron used for radioisotope production and multi-disciplinary research. For currents from 1 pA to 20 µA, Ce3+ and Sb3+ doped silica fibers were used as sensors. Read out systems based on photodiodes, photomultipliers and solid state photomultipliers were employed. Profiles down to the pA range were measured with this method for the first time. For currents ranging from 1 pA to 3 µA, the integral of the profile was found to be linear with respect to the beam current, which can be measured by this detector with an accuracy of ∼1%. The profile was determined with a spatial resolution of 0.25 mm. For currents ranging from 5 µA to 20 µA, thermal effects affect light yield and transmission, causing distortions of the profile and limitations in monitoring capabilities. For currents higher than ∼1 µA, non doped optical fibers for both producing and transporting scintillation light were also successfully employed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The understanding of the continental carbon budget is essential to predict future climate change. In order to quantify CO₂ and CH₄ fluxes at the regional scale, a measurement system was installed at the former radio tower in Beromünster as part of the Swiss greenhouse gas monitoring network (CarboCount CH). We have been measuring the mixing ratios of CO₂, CH₄ and CO on this tower with sample inlets at 12.5, 44.6, 71.5, 131.6 and 212.5 m above ground level using a cavity ring down spectroscopy (CRDS) analyzer. The first 2-year (December 2012–December 2014) continuous atmospheric record was analyzed for seasonal and diurnal variations and interspecies correlations. In addition, storage fluxes were calculated from the hourly profiles along the tower. The atmospheric growth rates from 2013 to 2014 determined from this 2-year data set were 1.78 ppm yr⁻¹, 9.66 ppb yr⁻¹ and and -1.27 ppb yr⁻¹ for CO₂, CH₄ and CO, respectively. After detrending, clear seasonal cycles were detected for CO₂ and CO, whereas CH₄ showed a stable baseline suggesting a net balance between sources and sinks over the course of the year. CO and CO₂ were strongly correlated (r² > 0.75) in winter (DJF), but almost uncorrelated in summer. In winter, anthropogenic emissions dominate the biospheric CO₂ fluxes and the variations in mixing ratios are large due to reduced vertical mixing. The diurnal variations of all species showed distinct cycles in spring and summer, with the lowest sampling level showing the most pronounced diurnal amplitudes. The storage flux estimates exhibited reasonable diurnal shapes for CO₂, but underestimated the strength of the surface sinks during daytime. This seems plausible, keeping in mind that we were only able to calculate the storage fluxes along the profile of the tower but not the flux into or out of this profile, since no Eddy covariance flux measurements were taken at the top of the tower.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The continuous plankton recorder (CPR) survey is an upper layer plankton monitoring program that has regularly collected samples, at monthly intervals, in the North Atlantic and adjacent seas since 1946. Water from approximately 6 m depth enters the CPR through a small aperture at the front of the sampler and travels down a tunnel where it passes through a silk filtering mesh of 270 µm before exiting at the back of the CPR. The plankton filtered on the silk is analyzed in sections corresponding to 10 nautical miles (approx. 3 m**3 of seawater filtered) and the plankton microscopically identified (Richardson et al., 2006 and reference therein). In the present study we used the CPR data to investigate the current basin scale distribution of C. finmarchicus (C5-C6), C. helgolandicus (C5-C6), C. hyperboreus (C5-C6), Pseudocalanus spp. (C6), Oithona spp. (C1-C6), total Euphausiida, total Thecosomata and the presence/absence of Cnidaria and the Phytoplankton Colour Index (PCI). The PCI, which is a visual assessment of the greenness of the silk, is used as an indicator of the distribution of total phytoplankton biomass across the Atlantic basin (Batten et al., 2003). Monthly data collected between 2000 and 2009 were gridded using the inverse-distance interpolation method, in which the interpolated values were the nodes of a 2 degree by 2 degree grid. The resulting twelve monthly matrices were then averaged within the year and in the case of the zooplankton the data were log-transformed (i.e. log10 (x+1).