996 resultados para Concentration technique
Resumo:
The aim of this work is to present the theoretical and experimental aspects of the mirage effect technique. We are especially interested in the concentration mirage effect, which is a powerful tool in the study of electrochemical reactions that produce ionic movements close to electrodes and to get some fundamental information on mass transport and charge transfer during electrochemical processes. Limitations of this technique are discussed as well as the recent attempts to overcome them.
Resumo:
Ultrasuodatus on tehokas entsyymiliuosten konsentrointi- ja puhdistusmenetelmä. Prosessin ongelmana on kuitenkin kalvojen likaantumisesta johtuva suodatuksen aikainen vuon pienentyminen ja kalvojen hankala puhdistaminen. Oikeilla kalvovalinnoilla ja optimaalisilla pesustrategioilla voidaan suodatus- ja pesuaikoja lyhentää ja nain parantaa suodatusprosessin tehokkuutta ja tuotteen laatua. Työn kirjallisessa osassa on käsitelty entsyymiliuosten ja polymeerikalvojen suodatusprosessiin vaikuttavia ominaisuuksia. Työssä on esitelty myös pesuaineiden ja pesukemikaalien ominaisuuksia sekä pesuprosessiin vaikuttavia tekijöitä. Työn kokeellinen osa koostui kahdesta osasta. Työn ensimmäisessä osassa etsittiin entsyymiliuosten ultrasuodatusprosessiin sopivaa kalvoa vertailemalla kalvojen permeabiliteetteja, hydrofiilisyytta, varausta ja peseytyvyyttä. Suodatuksissa käytettiin kahta Roal Oy:n tuottamaa entsyymiliuosta ja suodatukset tehtiin DSS Labstak M20-laitteistolla. Työn toisen osan tarkoituksena oli etsiä entsyymiliuosten suodatuksessa käytettävien kalvojen likaantumisen syyt sekä tehokas puhdistusaine kalvojen pesuun. Tehokasta pesuainetta etsittiin liotuskokeilla ja laboratoriomittakaavan poikkivirtauslaitteistolla. Analysointeja tehtiin muun muassa FTIR- spektroskoopilla, vuomittauksilla, pyyhkäisyelektronimikroskoopilla ja kontaktikulmamittauksilla. Entsyymiliuosten suodatuksiin sopivan kalvon etsinnässä testattujen kalvojen välillä oli suuria eroja niin permeabiliteeteissa kuin likaantumisessa ja puhdistumisessa, mutta mikään kalvoista ei erottunut ylivoimaisesti parhaaksi. Pesuaineista kaupalliset membraanien puhdistukseen tarkoitetut emäksiset pesuaineet osoittautuivat tehokkaimmiksi lian poistajiksi.
Resumo:
The design and use of a novel apparatus for a variant of vacuum distillation is described. Relative to a conventional device, the apparatus/technique described permits superior recovery of multigram quantities of moderately volatile liquids from vacuum distillations.
Resumo:
In many industries, such as petroleum production, and the petrochemical, metal, food and cosmetics industries, wastewaters containing an emulsion of oil in water are often produced. The emulsions consist of water (up to 90%), oils (mineral, animal, vegetable and synthetic), surfactants and other contaminates. In view of its toxic nature and its deleterious effects on the surrounding environment (soil, water) such wastewater needs to be treated before release into natural water ways. Membrane-based processes have successfully been applied in industrial applications and are considered as possible candidates for the treatment of oily wastewaters. Easy operation, lower cost, and in some cases, the ability to reduce contaminants below existing pollution limits are the main advantages of these systems. The main drawback of membranes is flux decline due tofouling and concentration polarisation. The complexity of oil-containing systems demands complementary studies on issues related to the mitigation of fouling and concentration polarisation in membranebased ultrafiltration. In this thesis the effect of different operating conditions (factors) on ultrafiltration of oily water is studied. Important factors are normally correlated and, therefore, their effect should be studied simultaneously. This work uses a novel approach to study different operating conditions, like pressure, flow velocity, and temperature, and solution properties, like oil concentration (cutting oil, diesel, kerosene), pH, and salt concentration (CaCl2 and NaCl)) in the ultrafiltration of oily water, simultaneously and in a systematic way using an experimental design approach. A hypothesis is developed to describe the interaction between the oil drops, salt and the membrane surface. The optimum conditions for ultrafiltration and the contribution of each factor in the ultrafiltration of oily water are evaluated. It is found that the effect on permeate flux of the various factors studied strongly depended on the type of oil, the type of membrane and the amount of salts. The thesis demonstrates that a system containing oil is very complex, and that fouling and flux decline can be observed even at very low pressures. This means that only the weak form of the critical flux exists for such systems. The cleaning of the fouled membranes and the influence of different parameters (flow velocity, temperature, time, pressure, and chemical concentration (SDS, NaOH)) were evaluated in this study. It was observed that fouling, and consequently cleaning, behaved differently for the studied membranes. Of the membranes studied, the membrane with the lowest propensity for fouling and the most easily cleaned was the regenerated cellulose membrane (C100H). In order to get more information about the interaction between the membrane and the components of the emulsion, a streaming potential study was performed on the membrane. The experiments were carried out at different pH and oil concentration. It was seen that oily water changed the surface charge of the membrane significantly. The surface charge and the streaming potential during different stages of filtration were measured and analysed being a new method for fouling of oil in this thesis. The surface charge varied in different stages of filtration. It was found that the surface charge of a cleaned membrane was not the same as initially; however, the permeability was equal to that of a virgin membrane. The effect of filtration mode was studied by performing the filtration in both cross-flow and deadend mode. The effect of salt on performance was considered in both studies. It was found that salt decreased the permeate flux even at low concentration. To test the effect of hydrophilicity change, the commercial membranes used in this thesis were modified by grafting (PNIPAAm) on their surfaces. A new technique (corona treatment) was used for this modification. The effect of modification on permeate flux and retention was evaluated. The modified membranes changed their pore size around 33oC resulting in different retention and permeability. The obtained results in this thesis can be applied to optimise the operation of a membrane plant under normal or shock conditions or to modify the process such that it becomes more efficient or effective.
Resumo:
Anthocyanins are among the most important plant pigments. Due to their potential benefits for human health, there is considerable interest in these natural pigments. Nonetheless, there is great difficulty in finding a technique that could provide the identification of structurally similar compounds and estimate the number and concentration of the species present. A lot of techniques have been tried to find the best methodology to extract information from these systems. In this paper, a review of the most important procedures is given, from the extraction to the identification of anthocyanins in natural extracts.
Resumo:
Extraction and clean-up are essential points in polycyclic aromatic hydrocarbon (PAHs) analysis in a solid matrix. This work compares extraction techniques and clean-up procedures for PAH analysis. PAH levels, their toxicological significance and source were also evaluated in the waters of the Cocó and Ceará rivers. The efficiency of PAH recovery was higher for the soxhlet and ultrasonic techniques. PAH recovery varied from 69.3 to 99.3%. Total PAH concentration (ΣHPA) varied from 720.73 to 2234.76 µg kg-1 (Cocó river) and 96.4 to 1859.21 µg kg-1 (Ceará river). The main PAH sources are pyrolytic processes and the levels were classified as medium so that adverse effects are possible.
Resumo:
In this work, a new adsorbent was prepared by microencapsulation of sulfoxine into chitosan microspheres by the spray drying technique. The new adsorbent was characterized by Raman spectroscopy, scanning electron microscopy and microanalysis of energy dispersive X-rays. The Cu(II) adsorption was studied as a function of pH, time and concentration. The optimum pH was found to be 6.0. The kinetic and equilibrium data showed that the adsorption process followed the pseudo second-order kinetic model and the Langmuir isotherm model over the entire concentration range. An increase of 8.0% in the maximum adsorption capacity of the adsorbent (53.8 mg g-1) was observed as compared to chitosan glutaraldehyde cross-linked microspheres.
Resumo:
Physicochemical constraints severely limit the number of molecules that can be considered as candidates for transdermal delivery. Iontophoresis is a non-invasive technique in which a weak electric current is used to enhance the penetration of molecules into or through the skin. In this review the underlying mechanisms that drive iontophoresis and the impact of key experimental parameters - namely, formulation, drug concentration and pH - on iontophoretic delivery efficiency are discussed. In the final section some devices that are currently commercialized are also described.
Resumo:
COD is an important parameter to estimate the concentration of organic contaminants. The closed system technique with the use of K2Cr2O7 is the most important one, however, it has the inconvenience to suffer positive chemical interferences from inorganic compounds such as Fe2+ and H2O2 (not enough reported in the literature). This paper considers a statistical-experimental set capable to validate a empirical mathematical model generated from a 23 experimental design, in the presence of Fe2+ and H2O2. The t test shows that mathematical model has 99,99999% confidence degree and the experimental validation test indicates absolute mean error of 4,70%.
Resumo:
The present paper reports a bacteria autonomous controlled concentrator prototype with a user-friendly interface for bench-top applications. It is based on a micro-fluidic lab-on-a-chip and its associated custom instrumentation, which consists in a dielectrophoretic actuator, to pre-concentrate the sample, and an impedance analyser, to measure concentrated bacteria levels. The system is composed by a single micro-fluidic chamber with interdigitated electrodes and a instrumentation with custom electronics. The prototype is supported by a real-time platform connected to a remote computer, which automatically controls the system and displays impedance data used to monitor the status of bacteria accumulation on-chip. The system automates the whole concentrating operation. Performance has been studied for controlled volumes of Escherichia coli (E. coli) samples injected into the micro-fluidic chip at constant flow rate of 10 μL/min. A media conductivity correcting protocol has been developed, as the preliminary results showed distortion of the impedance analyser measurement produced by bacterial media conductivity variations through time. With the correcting protocol, the measured impedance values were related to the quantity of bacteria concentrated with a correlation of 0.988 and a coefficient of variation of 3.1%. Feasibility of E. coli on-chip automated concentration, using the miniaturized system, has been demonstrated. Furthermore, the impedance monitoring protocol had been adjusted and optimized, to handle changes in the electrical properties of the bacteria media over time.
Resumo:
Mixed-micelle formation between sodium chlolate (NaC) and the anionic surfactant sodium dodecanoate (SDoD) in Tris-HCl buffer solutions, pH 9.00, varying the molar fraction of the surfactants, was investigated by means of electrical conductivity and steady-state fluorescence of pyrene. The critical micelar concentration (cmc) was measured from the equivalent conductance versus the square root of the molar surfactant concentration plots and the regular solution theory (RST) was used to predict the mixing behavior. The I1/I3 pyrene ratio-surfactant concentration plots were used as an additional technique to follow the behavior and the changes in the micropolarity of the mixed micelles.
Resumo:
The electrochemical behaviour of zinc has been extensively studied in alkaline and acid media, but only a few studies have been reported in neutral solutions, particularly in deaerated media. Zinc passivation in neutral medium and the effect of the ClO4- ion on the nucleation and growth of the passive layer is studied in this paper by a transient technique at different electrolyte concentrations and applied potentials. ZnO growth rate was shown to decrease with increasing electrolyte concentration. Moreover, passive layer growth occurred followed by pitting nucleation and growth. Film growth and pit nucleation are explained by means of the Macdonald and Engell-Stolica models.
Resumo:
Capillary electrophoresis has become a well-established and routine-based separation technique. It is based on the differences between charged analyte mobility in aqueous or organic electrolytes. Its major limitation is the sensitivity due to small sample injection volumes and the narrow diameter of the capillaries, especially when UV detection is used. There are a number of ways to increase the concentration sensitivity. This report shows some on-line preconcentration strategies to perform it in free solution capillary electrophoresis that are based on manipulation of the analyte electrophoretic velocity during the sample introduction (stacking, field amplification and transient isotachophoresis).
Resumo:
Signal processing methods based on the combined use of the continuous wavelet transform (CWT) and zero-crossing technique were applied to the simultaneous spectrophotometric determination of perindopril (PER) and indapamide (IND) in tablets. These signal processing methods do not require any priory separation step. Initially, various wavelet families were tested to identify the optimum signal processing giving the best recovery results. From this procedure, the Haar and Biorthogonal1.5 continuous wavelet transform (HAAR-CWT and BIOR1.5-CWT, respectively) were found suitable for the analysis of the related compounds. After transformation of the absorbance vectors by using HAAR-CWT and BIOR1.5-CWT, the CWT-coefficients were drawn as a graph versus wavelength and then the HAAR-CWT and BIOR1.5-CWT spectra were obtained. Calibration graphs for PER and IND were obtained by measuring the CWT amplitudes at 231.1 and 291.0 nm in the HAAR-CWT spectra and at 228.5 and 246.8 nm in BIOR1.5-CWT spectra, respectively. In order to compare the performance of HAAR-CWT and BIOR1.5-CWT approaches, derivative spectrophotometric (DS) method and HPLC as comparison methods, were applied to the PER-IND samples. In this DS method, first derivative absorbance values at 221.6 for PER and 282.7 nm for IND were used to obtain the calibration graphs. The validation of the CWT and DS signal processing methods was carried out by using the recovery study and standard addition technique. In the following step, these methods were successfully applied to the commercial tablets containing PER and IND compounds and good accuracy and precision were reported for the experimental results obtained by all proposed signal processing methods.
Resumo:
A photometric procedure was developed for determination of aflatoxin B1 in peanuts by TLC-CCD technique. The quantification and detection limit were 1.2 μg kg-1 and 0.4 ng per spot, respectively, with mean recovery of 98%. The CCD camera is sufficiently sensitive to detect small changes in spots fluorescence intensity and the results for performance confirmed the efficiency of the method. Another important property of CCD detector is its linearity for a wide range of luminous stimulus determined by analysis of five-point calibration curves using the intensity of AFB1 fluorescence versus AFB1 concentration (0.8 to 4.8 ng per spot). The method was applied to the analysis of thirty nine peanut samples and aflatoxin B1 levels ranged from 16 to 115 μg kg-1. The TLC-CCD and the photometric procedure developed in this study demonstrated to be a simple and efficient tool for quantitative analyses of AFB1 in peanut samples.