978 resultados para Compact wideband antenna
Resumo:
This paper provides a review of antennas applied for indoor positioning or localization systems. The desired requirements of those antennas when integrated in anchor nodes (reference nodes) are discussed, according to different localization techniques and their performance. The described antennas will be subdivided into the following sections according to the nature of measurements: received signal strength (RSS), time of flight (ToF), and direction of arrival (DoA). This paper intends to provide a useful guide for antenna designers who are interested in developing suitable antennas for indoor localization systems.
Resumo:
O tratamento das águas residuais é uma matéria de extrema importância para o município da Póvoa de Varzim, não só por uma questão de saúde pública e conservação do meio ambiente como também pela vertente turística deste concelho, que tem na sua orla costeira seis praias às quais foram atribuídas bandeiras azuis pela sua qualidade. O concelho da Póvoa de Varzim engloba doze freguesias e possui quinze estações de tratamento de águas residuais (ETARs), sendo catorze delas compactas. O seu controlo é assegurado pela divisão de saneamento básico da câmara municipal da Póvoa de Varzim. O objetivo deste trabalho foi o diagnóstico de funcionamento das ETARs do município tendo em vista a identificação dos problemas existentes e a sua resolução/otimização. De forma a poder identificar o princípio de funcionamento e a presença de anomalias nas estações de tratamento, foram realizadas várias visitas a cada uma delas ao longo do período de estágio. A recolha de amostras para análises dos diferentes parâmetros foi feita por um funcionário e estas foram enviadas para o laboratório com parceria com a Câmara Municipal. Após uma extensa recolha de informação no local e de um estudo exaustivo de toda a documentação associada a cada ETAR concluiu-se que apenas quatro delas apresentavam problemas revelantes. As ETARs do parque industrial de Laúndos e do centro histórico de Rates apresentam caudais de admissão bastante elevados devido à descarga pontual de camiões cisterna o que faz com que o tratamento não seja eficaz. Como solução sugeriu-se a construção de um tanque de equalização em ambas as ETARs, com agitador e regulador de caudal, de forma a garantir, respetivamente, a mistura e uniformização das águas residuais domésticas e industriais e que apenas será bombeado o caudal adequado para tratamento. As ETARs da Incondave e das Fontaínhas apresentam sobretudo anomalias a nível do equipamento, o que leva a um mau desempenho da instalação. Aconselhou-se o conserto dos equipamentos danificados e uma inspeção mais frequente das instalações para que mal ocorra uma avaria, esta seja reparada o mais depressa possível. O estágio na câmara municipal da Póvoa de Varzim (CMPV) teve a duração de 10 meses, entre Outubro e Julho de 2012 e foi realizado no âmbito da disciplina de dissertação/ estágio do mestrado de tecnologias de proteção ambiental no Instituto Superior de Engenharia do Porto. Este estágio foi uma mais-valia para mim na medida em que pude consolidar os conhecimentos adquiridos ao longo de todo o meu percurso académico e conhecer a realidade do mercado de trabalho.
Resumo:
Background: Brown adipose tissue (BAT) plays an important role in whole body metabolism and could potentially mediate weight gain and insulin sensitivity. Although some imaging techniques allow BAT detection, there are currently no viable methods for continuous acquisition of BAT energy expenditure. We present a non-invasive technique for long term monitoring of BAT metabolism using microwave radiometry. Methods: A multilayer 3D computational model was created in HFSS™ with 1.5 mm skin, 3-10 mm subcutaneous fat, 200 mm muscle and a BAT region (2-6 cm3) located between fat and muscle. Based on this model, a log-spiral antenna was designed and optimized to maximize reception of thermal emissions from the target (BAT). The power absorption patterns calculated in HFSS™ were combined with simulated thermal distributions computed in COMSOL® to predict radiometric signal measured from an ultra-low-noise microwave radiometer. The power received by the antenna was characterized as a function of different levels of BAT metabolism under cold and noradrenergic stimulation. Results: The optimized frequency band was 1.5-2.2 GHz, with averaged antenna efficiency of 19%. The simulated power received by the radiometric antenna increased 2-9 mdBm (noradrenergic stimulus) and 4-15 mdBm (cold stimulus) corresponding to increased 15-fold BAT metabolism. Conclusions: Results demonstrated the ability to detect thermal radiation from small volumes (2-6 cm3) of BAT located up to 12 mm deep and to monitor small changes (0.5°C) in BAT metabolism. As such, the developed miniature radiometric antenna sensor appears suitable for non-invasive long term monitoring of BAT metabolism.
Resumo:
Tese para obter o grau de Mestre em Engenharia Electrónica e Telecomunicações
Resumo:
The intent of this dissertation is to review relevant existing management systems and chemical industry initiatives to identify synergies, overlaps and gaps with Sustainability best practices, to map the barriers to the incorporation of Sustainability and formulate recommendations to facilitate execution of Sustainability practices within existing management systems. A chemical industry Sustainability survey was conducted through APEQ, the Portuguese association of chemical companies, which constitutes the first baseline on the topic for this national industry association. The commonly used international standards and the Responsible Care® (RC) initiative were cross-referenced against the United Nations Global Compact Assessment Tool. Guidance on how to incorporate Sustainability into a company‘s modus operandi was collapsed into Sustainability Playbooks. The survey revealed that 73% of the APEQ member companies that participated in the survey have a Sustainability Plan. Both large and small/medium APEQ member companies see the market not willing to pay extra for ‗greener‘ products as one of the main barriers. APEQ large enterprise see complexity of implementation and low return on investment as the other most significant barriers while small/medium enterprise respond that the difficulty to predict customer sustainability needs is the other most significant barrier. Amongst many other insights from this survey reported to APEQ, Life Cycle Assessment practices were found to have a low level of implementation and were also considered of low importance, thus identifying a very important opportunity in Sustainability practices to be addressed by APEQ. Two hundred and seventy three assessment points from United Nations Global Compact Assessment Tool plus five additional items were cross-referenced with international standard requirements. With the authorization of the intellectual property owners, the United Nations Global Compact Assessment Tool was modified to introduce actionable recommendations for each gap identified by management standard. This tool was automated to output specific recommendations for 63 possible combinations after simply selecting from a list of commonly used management standards and the RC initiative. Finally this modified tool was introduced into Playbooks for Incorporation of Sustainability at two levels: a ―Get Started Playbook‖ for beginners or small/medium size enterprise and an ―Advanced Playbook‖ as a second advancement stage or for large enterprise.
Resumo:
The objective of this paper is to analyze the forearm muscular contraction levels associated to the use of anti-vibration gloves, by comparing the contraction levels with gloves and without gloves. Two different vibration tools were used in a simulated work environment: (1) A compact Duty Multi-Cutter Bosch and (2) and a Percussion Drill with a drill bit Ø20 mm. Standard operations were performed by each subject in the following materials: (1) Performing cross- sectional cuts in 80x40 mm pine section and (2) performing 20 mm diameter holes in a concrete slab 2 x 2 m, 70 mm thick. The forearm contraction level were measured by surface electromyography in four different muscles: Flexor Digitorum Superficialis (FDS), Flexor Carpi Ulnaris (FCU), Extensor Carpi Radialis Longus (ECRL) e Extensor Carpi Ulnaris (ECU). For the flexor muscles (FDS, FCU), an increase tendency in muscular contraction was observed when the operations are performed without gloves (2-5% MVE increase in the FDS and 3-9% MVE increase in the FCU). For the extensor muscles ECU a decrease tendency in muscular contraction was observed when the operations are performed without gloves (1-10% MVE decrease). Any tendency was found in the ECRL muscle. ECU was the muscle with the highest contraction level for 79% and 71% of the operators, during the operations respectively with the multi-cutter (P50= 27-30%MVE) and with the percussion drill (P50=46-55%MVE). As a final conclusion from this study, anti- vibration gloves may increase the forearm fatigue in the posterior region of the forearm (ECU muscle) during operations with the mentioned tools
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia de Eletrónica e Computadores
Resumo:
The paper presents a study on business micro-location behaviour as well as corresponding factors of influence, conducted in two metropolitan areas, Bucharest-Ilfov (Romania) and Greater Porto (Portugal). By business micro-location we refer to a specific site such as a building or facility, accommodating a business within a small, compact geographical area (e.g. metropolitan area). At this geographical scale, the macroeconomic layer factors were excluded, applicable when discern between regions or countries. The factors derived from location theory and previous empirical studies were surveyed, completing a cross-sectional analysis in order to find out the specific weights of the location factors and preferences, by region and by industry. Based on already established firms’ feedback on location, the specific weights were granted by each industry to the main location factors, types of areas, and types of accommodation facilities. The authors also suggested a model to integrate these results into a Geographical Information System (GIS).
Resumo:
Portugal é um país dependente da energia do exterior, devido à elevada percentagem de consumo de energia a partir de fontes primárias, como por exemplo o gasóleo. Para colmatar este cenário, têm vindo a criar-se incentivos para o uso de energias renováveis e para intensificação de medidas de eficiência energética, como os sistemas de cogeração, de forma a tornar os processos industriais nacionais mais autónomos e mais competitivos. O presente trabalho, centra-se na determinação do potencial térmico disponível na central de trigeração da empresa Monteiro, Ribas-Indústria, SA, com a finalidade de identificar a quantidade de energia não utilizada, com vista ao aproveitamento dessa mesma energia nos processos mais problemáticos da empresa. Verificou-se que a água líquida era a fonte de maior energia não aproveitada, representando cerca de 30%, relativamente à energia disponível na água de refrigeração que é de 1890 kW. Assim, perante este facto, fez-se um estudo em dois setores autónomos da empresa, o setor dos revestimentos e o setor dos componentes técnicos da borracha. Pretendeu-se propor medidas para melhorar os seus processos produtivos, aproveitando essa energia. Para o efeito foi projetado um permutador de calor de placas com necessidade energética de 131,4 MWh, no setor dos revestimentos e um permutador compacto no setor de produção de placas de borracha, necessitando de uma energia de 335,2 MWh. Face à energia disponível na central de trigeração, de 161,9 MWh, verifica-se que esta apenas poderá ser aproveitada no setor dos revestimentos. Para tornar este objetivo real, a empresa Monteiro, Ribas- Indústria, SA necessitaria de efetuar um investimento no total de 49.390€. Além disso, foi contabilizado o rendimento das caldeiras da central térmica e da cogeração, ambas pelo método direto, apresentando estas os valores de 72% e 42%, respectivamente.
Resumo:
Resumo: Cement, as well as the remaining constituents of self-compacting mortars, must be carefully selected, in order to obtain an adequate composition with a granular mix as compact as possible and a good performance in the fresh state (self-compacting effect) and the hardened state (mechanical and durability-related behavior). Therefore in this work the possibility of incorporating nano particles in self-compacting mortars was studied. Nano materials are very reactive due mostly to their high specific surface and show a great potential to improve the properties of these mortars, both in mechanical and durability terms. In this work two nano materials were used, nano silica (nano SiO2) in colloidal state and nano titanium (nano TiO2) in amorphous state, in two types of self-compacting mortars (ratio binder:sand of 1:1 and 1:2). The self-compacting mortar mixes have the same water/cement ratio and 30% of replacement of cement with fly ashes. The influence of nano materials nano-SiO2 and nano-TiO2 on the fresh and hardened state properties of these self-compacting mortars was studied. The results show that the use of nano materials in repair and rehabilitation mortars has significant potential but still needs to be optimized. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
This paper presents the design of low-cost, conformal UHF antennas and RFID tags on two types of cork substrates: 1) natural cork and 2) agglomerate cork. Such RFID tags find an application in wine bottle and barrel identification, and in addition, they are suitable for numerous antenna-based sensing applications. This paper includes the high-frequency characterization of the selected cork substrates considering the anisotropic behavior of such materials. In addition, the variation of their permittivity values as a function of the humidity is also verified. As a proof-of-concept demonstration, three conformal RFID tags have been implemented on cork, and their performance has been evaluated using both a commercial Alien ALR8800 reader and an in-house measurement setup. The reading of all tags has been checked, and a satisfactory performance has been verified, with reading ranges spanning from 0.3 to 6 m. In addition, this paper discusses how inkjet printing can be applied to cork surfaces, and an RFID tag printed on cork is used as a humidity sensor. Its performance is tested under different humidity conditions, and a good range in excess of 3 m has been achieved, allied to a good sensitivity obtained with a shift of >5 dB in threshold power of the tag for different humid conditions.
Resumo:
The Moncorvo Ordovician ironstones in northeastern Portugal consist of iron ore sedimentary horizons frequently interbanded with psamites and quartzites. Ore reserves may probably exceed 1 000 million tonnes and this makes Moncorvo the largest iron ore deposit in the European Union. Compact poorly banded massive layers may exceed 90 meters in thickness which is quite an extraordinary feature for a Phanerozoic deposit. If the thickness of Precambrian deposits may reach a few hundred meters, the thickness of Phanerozoic deposits never exceed a maximum of 15 meters generally forming a number of comparatively thin layers confined to a particular member of a sedimentary sequence. A detailed microscopic analysis of the ores revealed that initially a compact magnetite/quartzite layer, detrital in character (the magnetite occasionally showing chromite cores), was deposited by entrapment in near shore lagoons where rivers debouched, rather than in the open sea. This stage was followed by oscilating and transgressive shore lines which gave rise to breaks in sedimentation in combined river delta and shallow water marine environment where detrital material and fine iron oxide and clay suspensions were deposited in fluctuating environments. These events gave rise to layers of both magnetite (martite) and specularite intergrown with quartz, silicates and phosphates. Textural and mineralogical studies show that the deposits consist of ferruginous clastic sediments and are not chemically deposited cherts. Field, geological and palaeontological evidence also supports a detrital origin, the facies being typical of zones rich in oxygen and close to the feeding continent. The uncommon huge development of Moncorvo was due to the fact that the deposits occur in restricted basins on a continental platform were clastic sediments were predominantly deposited. Not only morphologically but also chemically the deposits are more similar to Precambrian iron formations than to Phanerozoic ironstones.
Resumo:
In the aim of the project "Recognition of the Miocene of the distal region of the Lower Tagus Basin through a borehole with continuous sampling", Temperature, Natural Gamma Ray, Neutron (almost in all the borehole), Sonic, SP and SPR (in two small sections in upper and lower parts of the Miocene Series) geophysical logs were carried on. Interpretation of those logs and comparison with chronological, lithostratigraphical, micropaleontological and clay mineraIs data; helped in the definition of depositional sequences and to obtain paleoenvironmental reconstructions that could lead to a better understanding of the evolution of the Setúbal Península and Lisboa regions Miocene gulf. Log data agree with the lithologic succession observed in the Belverde borehole, essentially silty sandstones/sandy siltstones (with variable clay content) to clays, often with marly intercalations. Sonic logs (and Neutron logs, in general) reflect the sediments porosity. The higher acoustic velocities are often related to compact/massive layers as claystones and/or limestones and rather fossiliferous marly layers. Lower values are obtained for porous, silty sandstones (fossiliferous and with scarce clay content) and bio-calcareous sandstones. As indicative, we obtained the mean values of 2500-3000m/s for the higher velocities and 1300-1600m/s for the lowest ones. ln Natural Gamma Ray log, the radiation peaks can be correlated to often fossiliferous marly micaceous layers. Radioactive micas are present. It seems that the gamma peaks and the depositional sequences previously defined for the Lower Tagus Basin (see Antunes et al., 1999, 2000; Pais et al., 2002) can be correlated, taking also into account the whole available micropaleontological, palynological and isotopic evidence.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Eletrónica e Telecomunicações