983 resultados para Calibration estimators


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our procedure to detect moving groups in the solar neighbourhood (Chen et al., 1997) in the four-dimensional space of the stellar velocity components and age has been improved. The method, which takes advantadge of non-parametric estimators of density distribution to avoid any a priori knowledge of the kinematic properties of these stellar groups, now includes the effect of observational errors on the process to select moving group stars, uses a better estimation of the density distribution of the total sample and field stars, and classifies moving group stars using all the available information. It is applied here to an accurately selected sample of early-type stars with known radial velocities and Strömgren photometry. Astrometric data are taken from the HIPPARCOS catalogue (ESA, 1997), which results in an important decrease in the observational errors with respect to ground-based data, and ensures the uniformity of the observed data. Both the improvement of our method and the use of precise astrometric data have allowed us not only to confirm the existence of classical moving groups, but also to detect finer structures that in several cases can be related to kinematic properties of nearby open clusters or associations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the application of the Soil and Water Assessment Tool (SWAT) model to the Maquoketa River watershed, located in northeast Iowa. The inputs to the model were obtained from the Environmental Protection Agency’s geographic information/database system called Better Assessment Science Integrating Point and Nonpoint Sources (BASINS). Climatic data from six weather stations located in and around the watershed, and measured streamflow data from a U.S. Geological Survey gage station at the watershed outlet were used in the sensitivity analysis of SWAT model parameters as well as its calibration and validation for watershed hydrology and streamflow. A sensitivity analysis was performed using an influence coefficient method to evaluate surface runoff and base flow variations in response to changes in model input hydrologic parameters. The curve number, evaporation compensation factor, and soil available water capacity were found to be the most sensitive parameters among eight selected parameters when applying SWAT to the Maquoketa River watershed. Model calibration, facilitated by the sensitivity analysis, was performed for the period 1988 through 1993, and validation was performed for 1982 through 1987. The model performance was evaluated by well-established statistical methods and was found to explain at least 86% and 69% of the variability in the measured stream flow data for the calibration and validation periods, respectively. This initial hydrologic modeling analysis will facilitate future applications of SWAT to the Maquoketa River watershed for various watershed analysis, including water quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have developed a processing methodology that allows crosshole ERT (electrical resistivity tomography) monitoring data to be used to derive temporal fluctuations of groundwater electrical resistivity and thereby characterize the dynamics of groundwater in a gravel aquifer as it is infiltrated by river water. Temporal variations of the raw ERT apparent-resistivity data were mainly sensitive to the resistivity (salinity), temperature and height of the groundwater, with the relative contributions of these effects depending on the time and the electrode configuration. To resolve the changes in groundwater resistivity, we first expressed fluctuations of temperature-detrended apparent-resistivity data as linear superpositions of (i) time series of riverwater-resistivity variations convolved with suitable filter functions and (ii) linear and quadratic representations of river-water-height variations multiplied by appropriate sensitivity factors; river-water height was determined to be a reliable proxy for groundwater height. Individual filter functions and sensitivity factors were obtained for each electrode configuration via deconvolution using a one month calibration period and then the predicted contributions related to changes in water height were removed prior to inversion of the temperature-detrended apparent-resistivity data. Applications of the filter functions and sensitivity factors accurately predicted the apparent-resistivity variations (the correlation coefficient was 0.98). Furthermore, the filtered ERT monitoring data and resultant time-lapse resistivity models correlated closely with independently measured groundwater electrical resistivity monitoring data and only weakly with the groundwater-height fluctuations. The inversion results based on the filtered ERT data also showed significantly less inversion artefacts than the raw data inversions. We observed resistivity increases of up to 10% and the arrival time peaks in the time-lapse resistivity models matched those in the groundwater resistivity monitoring data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Images acquired using optical microscopes are inherently subject to vignetting effects due to imperfect illumination and image acquisition. However, such vignetting effects hamper accurate extraction of quantitative information from biological images, leading to less effective image segmentation and increased noise in the measurements. Here, we describe a rapid and effective method for vignetting correction, which generates an estimate for a correction function from the background fluorescence without the need to acquire additional calibration images. We validate the usefulness of this algorithm using artificially distorted images as a gold standard for assessing the accuracy of the applied correction and then demonstrate that this correction method enables the reliable detection of biologically relevant variation in cell populations. A simple user interface called FlattifY was developed and integrated into the image analysis platform YeastQuant to facilitate easy application of vignetting correction to a wide range of images.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The activity of radiopharmaceuticals in nuclear medicine is measured before patient injection with radionuclide calibrators. In Switzerland, the general requirements for quality controls are defined in a federal ordinance and a directive of the Federal Office of Metrology (METAS) which require each instrument to be verified. A set of three gamma sources (Co-57, Cs-137 and Co-60) is used to verify the response of radionuclide calibrators in the gamma energy range of their use. A beta source, a mixture of (90)Sr and (90)Y in secular equilibrium, is used as well. Manufacturers are responsible for the calibration factors. The main goal of the study was to monitor the validity of the calibration factors by using two sources: a (90)Sr/(90)Y source and a (18)F source. The three types of commercial radionuclide calibrators tested do not have a calibration factor for the mixture but only for (90)Y. Activity measurements of a (90)Sr/(90)Y source with the (90)Y calibration factor are performed in order to correct for the extra-contribution of (90)Sr. The value of the correction factor was found to be 1.113 whereas Monte Carlo simulations of the radionuclide calibrators estimate the correction factor to be 1.117. Measurements with (18)F sources in a specific geometry are also performed. Since this radionuclide is widely used in Swiss hospitals equipped with PET and PET-CT, the metrology of the (18)F is very important. The (18)F response normalized to the (137)Cs response shows that the difference with a reference value does not exceed 3% for the three types of radionuclide calibrators.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intensification of agricultural production without a sound management and regulations can lead to severe environmental problems, as in Western Santa Catarina State, Brazil, where intensive swine production has caused large accumulations of manure and consequently water pollution. Natural resource scientists are asked by decision-makers for advice on management and regulatory decisions. Distributed environmental models are useful tools, since they can be used to explore consequences of various management practices. However, in many areas of the world, quantitative data for model calibration and validation are lacking. The data-intensive distributed environmental model AgNPS was applied in a data-poor environment, the upper catchment (2,520 ha) of the Ariranhazinho River, near the city of Seara, in Santa Catarina State. Steps included data preparation, cell size selection, sensitivity analysis, model calibration and application to different management scenarios. The model was calibrated based on a best guess for model parameters and on a pragmatic sensitivity analysis. The parameters were adjusted to match model outputs (runoff volume, peak runoff rate and sediment concentration) closely with the sparse observed data. A modelling grid cell resolution of 150 m adduced appropriate and computer-fit results. The rainfall runoff response of the AgNPS model was calibrated using three separate rainfall ranges (< 25, 25-60, > 60 mm). Predicted sediment concentrations were consistently six to ten times higher than observed, probably due to sediment trapping along vegetated channel banks. Predicted N and P concentrations in stream water ranged from just below to well above regulatory norms. Expert knowledge of the area, in addition to experience reported in the literature, was able to compensate in part for limited calibration data. Several scenarios (actual, recommended and excessive manure applications, and point source pollution from swine operations) could be compared by the model, using a relative ranking rather than quantitative predictions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recientemente, ha aumentado mucho el interés por la aplicación de los modelos de memoria larga a variables económicas, sobre todo los modelos ARFIMA. Sin duda , el método más usado para la estimación de estos modelos en el ámbito del análisis económico es el propuesto por Geweke y Portero-Hudak (GPH) aun cuando en trabajos recientes se ha demostrado que, en ciertos casos, este estimador presenta un sesgo muy importante. De ahí que, se propone una extensión de este estimador a partir del modelo exponencial propuesto por Bloomfield, y que permite corregir este sesgo.A continuación, se analiza y compara el comportamiento de ambos estimadores en muestras no muy grandes y se comprueba como el estimador propuesto presenta un error cuadrático medio menor que el estimador GPH

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The deficiency or excess of micronutrients has been determined by analyses of soil and plant tissue. In Brazil, the lack of studies that would define and standardize extraction and determination methods, as well as lack of correlation and calibration studies, makes it difficult to establish limits of concentration classes for analysis interpretation and fertilizer recommendations for crops. A specific extractor for soil analysis is sometimes chosen due to the ease of use in the laboratory and not in view of its efficiency in determining a bioavailable nutrient. The objectives of this study were to: (a) evaluate B concentrations in the soil as related to the fertilizer rate, soil depth and extractor; (b) verify the nutrient movement in the soil profile; (c) evaluate efficiency of Hot Water, Mehlich-1 and Mehlich-3 as available B extractors, using sunflower as test plant. The experimental design consisted of complete randomized blocks with four replications and treatments of five B rates (0, 2, 4, 6, and 8 kg ha-1) applied to the soil surface and evaluated at six depths (0-0.05, 0.05-0.10, 0.10-0.15, 0.15-0.20, 0.20-0.30, and 0.30-0.40 m). Boron concentrations in the soil extracted by Hot Water, Mehlich-1 and Mehlich-3 extractors increased linearly in relation to B rates at all depths evaluated, indicating B mobility in the profile. The extractors had different B extraction capacities, but were all efficient to evaluate bioavailability of the nutrient to sunflower. Mehlich-1 and Mehlich-3 can therefore be used to analyze B as well as Hot Water.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The flourishing number of publications on the use of isotope ratio mass spectrometry (IRMS) in forensic science denotes the enthusiasm and the attraction generated by this technology. IRMS has demonstrated its potential to distinguish chemically identical compounds coming from different sources. Despite the numerous applications of IRMS to a wide range of forensic materials, its implementation in a forensic framework is less straightforward than it appears. In addition, each laboratory has developed its own strategy of analysis on calibration, sequence design, standards utilisation and data treatment without a clear consensus.Through the experience acquired from research undertaken in different forensic fields, we propose a methodological framework of the whole process using IRMS methods. We emphasize the importance of considering isotopic results as part of a whole approach, when applying this technology to a particular forensic issue. The process is divided into six different steps, which should be considered for a thoughtful and relevant application. The dissection of this process into fundamental steps, further detailed, enables a better understanding of the essential, though not exhaustive, factors that have to be considered in order to obtain results of quality and sufficiently robust to proceed to retrospective analyses or interlaboratory comparisons.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bacterial degradation of polycyclic aromatic hydrocarbons (PAHs), ubiquitous contaminants from oil and coal, is typically limited by poor accessibility of the contaminant to the bacteria. In order to measure PAH availability in complex systems, we designed a number of diffusion-based assays with a double-tagged bacterial reporter strain Burkholderia sartisoli RP037-mChe. The reporter strain is capable of mineralizing phenanthrene (PHE) and induces the expression of enhanced green fluorescent protein (eGFP) as a function of the PAH flux to the cell. At the same time, it produces a second autofluorescent protein (mCherry) in constitutive manner. Quantitative epifluorescence imaging was deployed in order to record reporter signals as a function of PAH availability. The reporter strain expressed eGFP proportionally to dosages of naphthalene or PHE in batch liquid cultures. To detect PAH diffusion from solid materials the reporter cells were embedded in 2 cm-sized agarose gel patches, and fluorescence was recorded over time for both markers as a function of distance to the PAH source. eGFP fluorescence gradients measured on known amounts of naphthalene or PHE served as calibration for quantifying PAH availability from contaminated soils. To detect reporter gene expression at even smaller diffusion distances, we mixed and immobilized cells with contaminated soils in an agarose gel. eGFP fluorescence measurements confirmed gel patch diffusion results that exposure to 2-3 mg lampblack soil gave four times higher expression than to material contaminated with 10 or 1 (mg PHE) g(-1).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The structural modeling of spatial dependence, using a geostatistical approach, is an indispensable tool to determine parameters that define this structure, applied on interpolation of values at unsampled points by kriging techniques. However, the estimation of parameters can be greatly affected by the presence of atypical observations in sampled data. The purpose of this study was to use diagnostic techniques in Gaussian spatial linear models in geostatistics to evaluate the sensitivity of maximum likelihood and restrict maximum likelihood estimators to small perturbations in these data. For this purpose, studies with simulated and experimental data were conducted. Results with simulated data showed that the diagnostic techniques were efficient to identify the perturbation in data. The results with real data indicated that atypical values among the sampled data may have a strong influence on thematic maps, thus changing the spatial dependence structure. The application of diagnostic techniques should be part of any geostatistical analysis, to ensure a better quality of the information from thematic maps.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Calibrated BOLD fMRI is a promising alternative to the classic BOLD contrast due to its reduced venous sensitivity and greater physiological specificity. The delayed adoption of this technique for cognitive studies may stem partly from a lack of information on the reproducibility of these measures in the context of cognitive tasks. In this study we have explored the applicability and reproducibility of a state-of-the-art calibrated BOLD technique using a complex functional task at 7 tesla. Reproducibility measures of BOLD, CBF, CMRO2 flow-metabolism coupling n and the calibration parameter M were compared and interpreted for three ROIs. We found an averaged intra-subject variation of CMRO2 of 8% across runs and 33% across days. BOLD (46% across runs, 36% across days), CBF (33% across runs, 46% across days) and M (41% across days) showed significantly higher intra-subject variability. Inter-subject variability was found to be high for all quantities, though CMRO2 was the most consistent across brain regions. The results of this study provide evidence that calibrated BOLD may be a viable alternative for longitudinal and cognitive MRI studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recientemente, ha aumentado mucho el interés por la aplicación de los modelos de memoria larga a variables económicas, sobre todo los modelos ARFIMA. Sin duda , el método más usado para la estimación de estos modelos en el ámbito del análisis económico es el propuesto por Geweke y Portero-Hudak (GPH) aun cuando en trabajos recientes se ha demostrado que, en ciertos casos, este estimador presenta un sesgo muy importante. De ahí que, se propone una extensión de este estimador a partir del modelo exponencial propuesto por Bloomfield, y que permite corregir este sesgo.A continuación, se analiza y compara el comportamiento de ambos estimadores en muestras no muy grandes y se comprueba como el estimador propuesto presenta un error cuadrático medio menor que el estimador GPH

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Soil moisture is the property which most greatly influences the soil dielectric constant, which is also influenced by soil mineralogy. The aim of this study was to determine mathematical models for soil moisture and the dielectric constant (Ka) for a Hapludalf, two clayey Hapludox and a very clayey Hapludox and test the reliability of universal models, such as those proposed by Topp and Ledieu and their co-workers in the 80's, and specific models to estimate soil moisture with a TDR. Soil samples were collected from the 0 to 0.30 m layer, sieved through a mesh of 0.002 m diameter and packed in PVC cylinders with a 0.1 m diameter and 0.3 m height. Seven samples of each soil class were saturated by capillarity and a probe composed of two rods was inserted in each one of them. Moisture readings began with the saturated soil and concluded when the soil was near permanent wilting point. In each step, the samples were weighed on a precision scale to calculate volumetric moisture. Linear and polynomial models were adjusted for each soil class and for all soils together between soil moisture and the dielectric constant. Accuracy of the models was evaluated by the coefficient of determination, the standard error of estimate and the 1:1 line. The models proposed by Topp and Ledieu and their co-workers were not adequate for estimating the moisture in the soil classes studied. The adjusted linear and polynomial models for the entire set of data of the four soil classes did not have sufficient accuracy for estimating soil moisture. The greater the soil clay and Fe oxide content, the greater the dielectric constant of the medium for a given volumetric moisture. The specific models, θ = 0.40283 - 0.04231 Ka + 0.00194 Ka² - 0.000022 Ka³ (Hapludox) θ = 0.01971 + 0.02902 Ka - 0.00086 Ka² + 0.000012 Ka³ (Hapludox -PF), θ = 0.01692 - 0.00507 Ka (Hapludalf) and θ = 0.08471 + 0.01145 Ka (Hapludox-CA), show greater accuracy and reliability for estimating soil moisture in the soil classes studied.