963 resultados para CONCENTRATED LOADS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

RATIONALE: AICAR (5-aminoimidazole-4-carboxamide 1β-D-ribofuranoside) is prohibited in sport according to rules established by the World Anti-Doping Agency. Doping control laboratories identify samples where AICAR abuse is suspected by measuring its urinary concentration and comparing the observed level with naturally occurring concentrations. As the inter-individual variance of urinary AICAR concentrations is large, this approach requires a complementary method to unambiguously prove the exogenous origin of AICAR. Therefore, a method for the determination of carbon isotope ratios (CIRs) of urinary AICAR has been developed and validated. METHODS: Concentrated urine samples were fractionated by means of liquid chromatography for analyte cleanup. Derivatization of AICAR yielding the trimethylsilylated analog was necessary to enable CIR determinations by gas chromatography/combustion/isotope ratio mass spectrometry. The method was tested for its repeatability and stability over time and a linear mixing model was applied to test for possible isotopic discrimination. A reference population of n = 63 males and females was investigated to calculate appropriate reference limits to differentiate endogenous from exogenous urinary AICAR. These limits were tested by an AICAR elimination study. RESULTS: The developed method fulfills all the requirements for adequate sports drug testing and was found to be fit for purpose. The investigated reference population showed a larger variability in the CIR of AICAR than of the endogenous steroids. Nevertheless, the calculated thresholds for differences between AICAR and endogenous steroids can be applied straightforwardly to evaluate suspicious doping control samples with the same statistical confidence as established e.g. for testosterone misuse. These thresholds enabled the detection of a single oral AICAR administration for more than 40 h. CONCLUSIONS: Determination of thee CIRs is the method of choice to distinguish between an endogenous and an exogenous source of urinary AICAR. The developed method will enable investigations into doping control samples with elevated urinary concentrations of AICAR and clearly differentiate between naturally produced/elevated and illicitly administered AICAR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A modified adsorption-elution method for the concentration of seeded rotavirus from water samples was used to determine various factors which affected the virus recovery. An enzyme-linked immunosorbent assay was used to detect the rotavirus antigen after concentration. Of the various eluents compared, 0.05M glycine, pH 11.5 gave the highest rotavirus antigen recovery using negatively charged membrane filtration whereas 2.9% tryptose phosphate broth containing 6% glycine; pH 9.0 was found to give the greatest elution efficiency when a positively charged membrane was used. Reconcentration of water samples by a speedVac concentrator showed significantly higher rotavirus recovery than polyethylene glycol precipitation through both negatively and positively charged filters (p-value <0.001). In addition, speedVac concentration using negatively charged filtration resulted in greater rotavirus recovery than that using positively charged filtration (p-value = 0.004). Thirty eight environmental water samples were collected from river, domestic sewage, canals receiving raw sewage drains, and tap water collected in containers for domestic use, all from congested areas of Bangkok. In addition, several samples of commercial drinking water were analyzed. All samples were concentrated and examined for rotavirus antigen. Coliforms and fecal coliforms (0->1,800 MPN/100 ml) were observed but rotavirus was not detected in any sample. This study suggests that the speedVac reconcentration method gives the most efficient rotavirus recovery from water samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En el nostre projecte, considerem un escenari urbà o interurbà on persones amb dispositius mòbils (smartphones) o vehicles equipats amb interfícies de comunicació, estan interessats en compartir fitxers entre ells o descarregar-los al creuar Punts d’Accés (APs) propers a la carretera. Estudiem la possibilitat d’utilizar la cooperació en les trobades casuals entre nodes per augmentar la velocitat de descàrrega global. Amb aquest objectiu, plantejem algoritmes per a la selecció de quins paquets, per a quins destins i quins transportistes s’escullen en cada moment. Mitjançant extenses simulacions, mostrem com les cooperacions carry&forward dels nodes augmenten significativament la velocitat de descàrrega dels usuaris, i com aquest resultat es manté per a diversos patrons de mobilitat, col•locacions d'AP i càrregues de la xarxa. Per altra banda, aparells com els smartphones, on la targeta de WiFi està encesa contínuament, consumeixen l'energia de la bateria en poques hores. En molts escenaris, una targeta WiFi sempre activa és poc útil, perque sovint no hi ha necessitat de transmissió o recepció. Aquest fet es veu agreujat en les Delay Tolerant Networks (DTN), on els nodes intercanvien dades quan es creuen i en tenen l’oportunitat. Les tècniques de gestió de l’estalvi d’energia permeten extendre la duració de les bateries. El nostre projecte analitza els avantatges i inconvenients que apareixen quan els nodes apaguen períodicament la seva targeta wireless per a estalviar energia en escenaris DTN. Els nostres resultats mostren les condicions en que un node pot desconnectar la bateria sense afectar la probabilitat de contacte amb altres nodes, i les condicions en que aquesta disminueix. Per exemple, es demostra que la vida del node pot ser duplicada mantenint la probabilitat de contacte a 1. I que aquesta disminueix ràpidament en intentar augmentar més la vida útil.