964 resultados para Aramaic-Syriac words


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Let’s face it, English is a complex language! I’m stating the obvious when I say that reading and writing (spelling) English is no walk in the park. The main source of difficulty comes from the fact that the English language uses 26 alphabet letters to make 40+ sounds (phonemes) represented via 120+ different written combinations. I’ve been rather vague about the number of phonemes and written combinations, for they keep growing as foreign language words are adopted and adapted into the English language.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Lumbar Epidural Steroids Injections (ESI’s) have previously been shown to provide some degree of pain relief in sciatica. Number Needed To Treat (NNT) to achieve 50% pain relief has been estimated at 7 from the results of randomised controlled trials. Pain relief is temporary. They remain one of the most commonly provided procedures in the UK. It is unknown whether this pain relief represents good value for money. Methods 228 patients were randomised into a multi-centre Double Blind Randomised Controlled Trial. Subjects received up to 3 ESI’s or intra-spinous saline depending on response and fall off with the first injection. All other treatments were permitted. All received a review of analgesia, education and physical therapy. Quality of life was assessed using the SF36 at 6 points and compared using independent sample t-tests. Follow up was up to 1 yr. Missing data was imputed using last observation carried forward (LOCF). QALY’s (Quality of Life Years) were derived from preference based heath values (summary health utility score). SF-6D health state classification was derived from SF-36 raw score data. Standard gambles (SG) were calculated using Model 10. SG scores were calculated on trial results. LOCF was not used for this. Instead average SG were derived for a subset of patients with observations for all visits up to week 12. Incremental QALY’s were derived as the difference in the area between the SG curve for the active group and placebo group. Results SF36 domains showed a significant improvement in pain at week 3 but this was not sustained (mean 54 Active vs 61 Placebo P<0.05). Other domains did not show any significant gains compared with placebo. For derivation of SG the number in the sample in each period differed. In week 12, average SG scores for active and placebo converged. In other words, the health gain for the active group as measured by SG was achieved by the placebo group by week 12. The incremental QALY gained for a patient under the trial protocol compared with the standard care package was 0.0059350. This is equivalent to an additional 2.2 days of full health. The cost per QALY gained to the provider from a patient management strategy administering one epidural as suggested by results was £25 745.68. This result was derived assuming that the gain in QALY data calculated for patients under the trial protocol would approximate that under a patient management strategy based on the trial results (one ESI). This is above the threshold suggested by some as a cost effective treatment. Conclusions The transient benefit in pain relief afforded by ESI’s does not appear to be cost-effective. Further work is needed to develop more cost-effective conservative treatments for sciatica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis developed new search engine models that elicit the meaning behind the words found in documents and queries, rather than simply matching keywords. These new models were applied to searching medical records: an area where search is particularly challenging yet can have significant benefits to our society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction This study investigates uncertainties pertaining to the use of optically stimulated luminescence dosimeters (OSLDs) in radiotherapy dosimetry. The sensitivity of the luminescent material is related to the density of recombination centres [1], which is in the range of 1015–1016 cm-3. Because of this non-uniform distribution of traps in crystal growth the sensitivity varies substantially within a batch of dosimeters. However, a quantitative understanding of the relationship between the response of an OSLD and its sensitive volume has not yet been investigated or reported in literature. Methods In this work, OSLDs are scanned with a MicroCT scanner to determine potential sources for the variation in relative sensitivity across a selection of Landauer nanoDot dosimeters. Specifically, the correlation between a dosimeters relative sensitivity and the loading density of Al2O3:C powder was determined. Results When extrapolating the sensitive volume’s radiodensity from the CT data, it was shown that there is a non-uniform distribution incrystal growth as illustrated in Fig. 1. A plot of voxel count versus the element-specific correction factor is shown in Fig. 2 where each point represents a single OSLD. A line was fitted which has an R2-value of 0.69 and a P-value of 8.21 9 10-19. This data shows that the response of a dosimeter decreases proportionally with sensitive volume. Extrapolating from this data, a quantitative relationship between response and sensitive volume was roughly determined for this batch of dosimeters. A change in volume of 1.176 9 10-5 cm3 corresponds to a 1 % change in response. In other words, a 0.05 % change in the nominal volume of the chip would result in a 1 % change in response. Discussion and conclusions This work demonstrated that the amount of sensitive material is approximately linked to the total correction factor. Furthermore, the ‘true’ volume of an OSLD’s sensitive material is, on average, 17.90 % less than that which has been reported in literature, mainly due to the presence of air cavities in the material’s structure. Finally, the potential effects of the inaccuracy of Al2O3:C deposition increases with decreasing chip size. If a luminescent dosimeter were manufactured with a smaller volume than currently employed using the same manufacturing protocol, the variation in response from chip to chip would more than likely exceed the current 5 % range.