975 resultados para Aortic depressor nerve
Resumo:
AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.
Resumo:
OBJECTIVE: The success of open and endovascular repair of abdominal aortic aneurysms (AAA) is hampered by postoperative dilatation of the anatomical neck of the AAA, which is used for graft attachment. The purpose of this study was to determine whether the macroscopically non-diseased infrarenal aortic neck of AAA is histologically and biochemically altered at the time of operative repair. METHODS: We harvested full-thickness aortic wall samples as longitudinal stripes spanning from AAA neck to aneurysmal sac in 22 consecutive patients undergoing open surgical AAA repair. Control tissue was obtained from five organ donors and five deceased subjects undergoing autopsy without evidence of aneurysmal disease. We assessed aortic media thickness, number of intact elastic lamellar units, media destruction, and neovascularization grade and performed immunohistochemistry for matrix metalloproteinase (MMP)-9 and phosphorylated c-Jun N-terminal kinase (p-JNK). MMP-9 and p-JNK protein expressions were quantified using Western Blots. RESULTS: The median thickness of the aortic media was 1150 mum in control tissue (range, 1000-1300), 510 mum in aortic necks (250-900), and 200 mum in aortic sacs (50-500, P from nonparametric test for trend <.001). The number of intact elastic lamellar units was 33 in controls (range, 33-55), 12 in aortic necks (0-31) and three in aortic sacs (0-10, P < .001). The expression of MMP-9 and p-JNK as assessed by Western Blots (P = .007 and .061, respectively) and zymography (P for trend <.001) were up regulated in both the AAA neck and sac compared with controls. Except for p-JNK expression, differences between tissues were similar after the adjustment for age, gender, and type of sampling. CONCLUSION: The seemingly non-diseased infrarenal AAA neck in patients with AAA undergoing surgical repair shows histological signs of destruction and upregulation of potential drug targets.
Resumo:
In an experiment on one of the authors, we used ultrasound to visualise an acupuncture needle completely perforating the median nerve at the acupuncture point PC6. During this procedure only a slight sensation occurred, and no pain. We conclude that, in individual cases, the median nerve might be perforated without causing pain or neurological problems.
Resumo:
The case of a 35-year-old woman with Klippel-Trenaunay-Weber syndrome (KTWS) showing clinical symptoms of a peroneal nerve lesion is presented. An immense nerve enlargement along most of the sciatic, peroneal and tibial nerve was found to be due to a lipoma arising from the epi- and perineurium. Treatment consisted of extensive microsurgical neurolysis and excision of the tumor resulting in decompression of the affected nerves. Although rare, a perineural lipoma should be kept in mind in patients with KTWS showing neurological abnormalities.
Resumo:
OBJECTIVE: The purpose of this article is to report our preliminary results regarding microsurgical repair of the sural nerve after nerve biopsy, in an attempt to reduce the well-described sensory morbidity and neuroma formation. METHODS: Three patients with a suspected diagnosis of peripheral neuropathy underwent sural nerve biopsies to establish definitive diagnoses. A 10-mm segment of the sural nerve was resected with local anesthesia. After harvesting of the specimen, the proximal and distal nerve stumps were carefully mobilized and united with epineural suture techniques, under a surgical microscope. Sensory evaluations (assessing the presence of hypesthesia/dysesthesia or pain) of the lateral aspect of the foot, in regions designated Areas 1, 2, and 3, were performed before and 6 and 12 months after the biopsies. A visual analog scale was used for pain estimation. RESULTS: The biopsy material was sufficient for histopathological examinations in all cases, leading to conclusive diagnoses (vasculitis in two cases and amyloidosis in one case). The early post-biopsy hypesthesia, which was present for 4 to 8 weeks, improved to preoperative levels as early as 6 months after the nerve repair. Sensory evaluations performed at 6- and 12-month follow-up times demonstrated that none of the patients complained of pain at the biopsy site or distally in the area innervated by the sural nerve. Ultrasonography performed at the 12-month follow-up examination revealed normal sural nerve morphological features, with no neuroma formation, comparable to findings for the contralateral site. CONCLUSION: Microsurgical repair of the sural nerve after biopsy can eliminate or reduce sensory disturbances such as paraesthesia, hypesthesia, and dysesthesia distal to the biopsy site, in the distribution of the sensory innervation of the sural nerve, and can prevent painful neuroma formation. To our knowledge, this article is the first in the literature to report on microsurgical repair of the sural nerve after nerve biopsy. Decreased side effects suggest that this technique can become a standard procedure after sural nerve biopsy, which is commonly required to establish the diagnosis of various diseases, such as peripheral nerve pathological conditions, vasculitis, and amyloidosis. More cases should be analyzed, however, to explore the usefulness of the technique and the reliability of sural nerve biopsy samples in attempts to obtain conclusive diagnoses.
Resumo:
This study compares MRI and MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms (EVAR). Forty-three patients with previous EVAR underwent both MRI (2D T1-FFE unenhanced and contrast-enhanced; 3D triphasic contrast-enhanced) and 16-slice MDCT (unenhanced and biphasic contrast-enhanced) within 1 week of each other for endoleak detection. MRI was performed by using a high-relaxivity contrast medium (gadobenate dimeglumine, MultiHance). Two blinded, independent observers evaluated MRI and MDCT separately. Consensus reading of MRI and MDCT studies was defined as reference standard. Sensitivity, specificity, and accuracy were calculated and Cohen's k statistics were used to estimate agreement between readers. Twenty endoleaks were detected in 18 patients at consensus reading (12 type II and 8 indeterminate endoleaks). Sensitivity, specificity, and accuracy for endoleak detection were 100%, 92%, and 96%, respectively, for reader 1 (95%, 81%, 87% for reader 2) for MRI and 55%, 100%, and 80% for reader 1 (60%, 100%, 82% for reader 2) for MDCT. Interobserver agreement was excellent for MDCT (k = 0.96) and good for MRI (k = 0.81). MRI with the use of a high-relaxivity contrast agent is significantly superior in the detection of endoleaks after EVAR compared with MDCT. MRI may therefore become the preferred technique for patient follow-up after EVAR.
Resumo:
BACKGROUND/AIM: To compare the ability of confocal scanning laser tomography (CSLT), scanning laser polarimetry (SLP) and optical coherence tomography (OCT) in recognising localised retinal nerve fibre layer (RNFL) defects. METHODS: 51 eyes from 43 patients with glaucoma were identified by two observers as having RNFL defects visible on optic disc photographs. 51 eyes of 32 normal subjects were used as controls. Three masked observers evaluated CSLT, SLP and OCT images to determine subjectively the presence of localised RNFL defects. RESULTS: Interobserver agreement was highest with OCT, followed by SLP and CSLT (mean kappa: 0.83, 0.69 and 0.64, respectively). RNFL defects were identified in 58.8% of CSLT, 66.7% of SLP and 54.9% of OCT (p = 0.02 between SLP and OCT) by at least two observers. In the controls, 94.1% of CSLT, 84.3% of SLP and 94.1% of OCT scans, respectively, were rated as normal (p = 0.02 between CSLT and SLP, and SLP and OCT). CONCLUSION: Approximately 20-40% of localised RNFL defects identified by colour optic disc photographs are not detected by CSLT, SPL or OCT. SLP showed a higher number of false-positive results than the other techniques, but also had a higher proportion of correctly identified RNFL defects in the glaucoma population.
Resumo:
OBJECTIVE: The implantation of a composite graft is the treatment of choice for patients with aortic root disease if the valve cannot be preserved and the patient is not a suitable candidate for a Ross procedure. Several years ago, the Shelhigh NR-2000C (Shelhigh, Inc, Millburn, NJ) was introduced in Europe. Being a totally biologic conduit and considering the lack of homografts, the graft seemed an ideal conduit for patients with destructive endocarditis, as well as for older patients who were not suitable candidates for oral anticoagulation. METHODS: From 2001 until 2006, the Shelhigh NR-2000C stentless valved conduit was implanted in 115 patients for various aortic root pathologies. The conduit consists of a bovine pericardial straight graft with an incorporated porcine stentless valve. Aortic root repair was performed during standard cardiopulmonary bypass and mild hypothermia in the majority of patients. Deep hypothermic circulatory arrest combined with selective antegrade cerebral perfusion was used when the repair extended into the arch. RESULTS: Seven patients with uncomplicated early outcome presented with unexpected sudden disastrous findings at the level of the aortic root, although 1-year follow-up computed tomographic scans were normal. Four of these patients underwent emergency operations because of desintegration of the graft, along with rupture of the aortic root. Retrospectively, the main findings were persistent fever or subfebrility over months and a halo-like enhancement on computed tomographic scans. Extensive microbiologic examinations were performed without finding a causative organism. CONCLUSION: The use of the Shelhigh aortic stentless conduit can no longer be advocated, and meticulous follow-up of patients in whom this device has been implanted has to be recommended.
Resumo:
OBJECTIVES: Endovascular repair of the descending thoracic aorta is a very promising technique in elective and, particularly, emergency situations. This study assessed the impact of urgency of the procedure on outcome and mid-term quality of life in surviving patients. METHODS: Post hoc analysis of prospectively collected data of 58 consecutive patients (January 2001-December 2005) with surgical pathologies of the descending thoracic aorta treated by endovascular means. Six patients were excluded due to recent operations on the ascending aorta before thoracic endovascular repair. The remaining patients (n=52) were 69+/-10 years old, and 43 were men (83%). Twenty-seven had been treated electively, and 25 for emergency indications. Reasons for emergency were acute type B aortic dissections with or without malperfusion syndrome in 14, and aortic ruptures in 11 cases. Follow-up was 29+/-16 months. Endpoints were perioperative and late morbidity and mortality rates and long-term quality of life as assessed by the short form health survey (SF-36) and Hospital Anxiety and Depression Scale questionnaires. RESULTS: Cohorts were comparable regarding age, sex, cardiovascular risk factors, and comorbidities. Perioperative mortality was somewhat higher in emergency cases (12% vs 4%, p=0.34). Paraplegia occurred in one patient in each cohort (4%). Overall quality of life after two and a half years was similar in both treatment cohorts: 72 (58-124) after emergency, and 85 (61-105) after elective endovascular aortic repair (p=0.98). Normal scores range from 85 to 115. Anxiety and depression scores were in the normal range and comparable. CONCLUSIONS: Thoracic endovascular aortic repair is an excellent and safe treatment option for the diseased descending aorta, particularly in emergency situations. Early morbidity and mortality rates can be kept very low. Mid-term quality of life was not affected by the urgency of the procedure. Similarly, mid-term anxiety and depression scores were not increased after emergency situations.
Resumo:
BACKGROUND: Thoracic endovascular aortic repair (TEVAR) represents an attractive alternative to open aortic repair (OAR). The aim of this study was to assess outcome and quality of life in patients treated either by TEVAR or OAR for diseased descending thoracic aorta. METHODS: A post hoc analysis of a prospectively collected consecutive series of 136 patients presenting with surgical diseases of the descending aorta between January 2001 and December 2005 was conducted. Fourteen patients were excluded because of involvement of the ascending aorta. Assessed treatment cohorts were TEVAR (n = 52) and OAR (n = 70). Mean follow-up was 34 +/- 18 months. End points were perioperative and late mortality rates and long-term quality of life as assessed by the Short Form Health Survey (SF-36) and Hospital Anxiety and Depression Score questionnaires. RESULTS: Mean age was significantly higher in TEVAR patients (69 +/- 10 years versus 62 +/- 15 years; p = 0.002). Perioperative mortality rates were 9% (OAR) and 8% (TEVAR), respectively (p = 0.254). Accordingly, cumulative long-term mortality rates were similar in both cohorts. Overall quality-of-life scores were 93 (63-110, OAR) and 83 (60-112, TEVAR), respectively. Normal quality-of-life scores range from 85 to 115. Anxiety and depression scores were not increased after open surgery. CONCLUSIONS: Thoracic endovascular aortic repair and OAR both provide excellent long-term results in treatment of thoracic aortic disease. Long-term quality of life, however, is reduced after thoracic aortic repair. Interestingly, TEVAR patients did not score higher in overall quality of life despite all advantages of minimized access trauma. Similarly, anxiety and depression scores are not reduced by TEVAR, possibly reflecting a certain caution against the new technology.