972 resultados para Air Pollution, Indoor
Resumo:
An integrated method for the prediction of the spatial pollution distribution within a street canyon directly from a microscopic traffic simulation model is outlined. The traffic simulation package Paramics is used to model the flow of vehicles in realistic traffic conditions on a real road network. This produces details of the amount of pollutant produced by each vehicle at any given time. The authors calculate the dispersion of the pollutant using a particle tracking diffusion method which is superimposed on a known velocity and turbulence field. This paper shows how these individual components may be integrated to provide a practical street canyon pollution model. The resulting street canyon pollution model provides isoconcentrations of pollutant within the road topography.
Resumo:
Indoor Air 2016 - The 14th International Conference Indoor Air Quality and Climate
Resumo:
The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air
Resumo:
Polycyclic aromatic hydrocarbons (PAHs) are common environmental pollutants that occur naturally in complex mixtures. Many of the adverse health effects of PAHs including cancer are linked to the activation of intracellular stress response signaling. This study has investigated intracellular MAPK signaling in response to PAHs in extracts from urban air collected in Stockholm, Sweden and Limeira, Brazil, in comparison to BP in HepG2 cells. Nanomolar concentrations of PAHs in the extracts induced activation of MEK4 signaling with down-stream increased gene expression of several important stress response mediators. Involvement of the MEK4/JNK pathway was confirmed using siRNA and an inhibitor of JNK signaling resulting in significantly reduced MAPK signaling transactivated by the AP-1 transcription factors ATF2 and c-Jun. ATF2 was also identified as a sensitive stress responsive protein with activation observed at extract concentrations equivalent to 0.1 nM BP. We show that exposure to low levels of environmental PAH mixtures more strongly activates these signaling pathways compared to BP alone suggesting effects due to interactions. Taken together, this is the first study showing the involvement of MEK4/JNK/AP-1 pathway in regulating the intracellular stress response after exposure to nanomolar levels of PAHs in environmental mixtures.
Resumo:
INTRODUÇÃO: O arco e flecha é um esporte estático que requer força e resistência da parte superior do corpo, sendo que a habilidade do arqueiro é definida pela capacidade de atirar a flecha no alvo em um intervalo de tempo com precisão. A contração muscular gerada durante a execução do gesto esportivo propicia o aumento da temperatura corporal, da oxidação de glicose e da sudorese, podendo esta ser potencializada pelas condições climáticas às quais o atleta é exposto. Todos estes fatores alteram a percepção de esforço e a própria geração de força, impondo um estresse negativo à performance. OBJETIVOS: Avaliar e relacionar o estado de hidratação de atletas de arco e flecha com alterações fisiológicas e de força intervenientes no rendimento competitivo. MÉTODOS: Participaram 11 arqueiros em duas competições distintas (indoor e outdoor). Foram mensurados parâmetros relacionados ao estado de hidratação, glicemia, percepção de esforço subjetivo e alteração na força de preensão palmar. RESULTADOS: Os atletas analisados apresentaram alterações significativas nos parâmetros relacionados ao estado hídrico em diferentes dias, provavelmente relacionadas às condições climáticas adversas na competição outdoor (34ºC e 60% URA) em relação à competição indoor (22ºC e 90% URA). O mesmo não foi observado para a glicemia. CONCLUSÃO: Este trabalho é o primeiro a comprovar a relação direta entre fatores climáticos e de rendimento em arqueiros de alto nível durante evento competitivo, assim como a evidenciar quais métodos não invasivos seriam os mais indicados para a avaliação do impacto destas alterações.
Resumo:
OBJECTIVE: To analyze the impact on human health of exposure to particulate matter emitted from burnings in the Brazilian Amazon region. METHODS: This was an ecological study using an environmental exposure indicator presented as the percentage of annual hours (AH%) of PM2.5 above 80 μg/m3. The outcome variables were the rates of hospitalization due to respiratory disease among children, the elderly and the intermediate age group, and due to childbirth. Data were obtained from the National Space Research Institute and the Ministry of Health for all of the microregions of the Brazilian Amazon region, for the years 2004 and 2005. Multiple regression models for the outcome variables in relation to the predictive variable AH% of PM2.5 above 80 μg/m3 were analyzed. The Human Development Index (HDI) and mean number of complete blood counts per 100 inhabitants in the Brazilian Amazon region were the control variables in the regression analyses. RESULTS: The association of the exposure indicator (AH%) was higher for the elderly than for other age groups (β = 0.10). For each 1% increase in the exposure indicator there was an increase of 8% in child hospitalization, 10% in hospitalization of the elderly, and 5% for the intermediate age group, even after controlling for HDI and mean number of complete blood counts. No association was found between the AH% and hospitalization due to childbirth. CONCLUSIONS: The indicator of atmospheric pollution showed an association with occurrences of respiratory diseases in the Brazilian Amazon region, especially in the more vulnerable age groups. This indicator may be used to assess the effects of forest burning on human health.
Resumo:
In this communication we describe the application of a conductive polymer gas sensor as an air pressure sensor. The device consists of a thin doped poly(4'-hexyloxy-2,5-biphenylene ethylene) (PHBPE) film deposited on an interdigitated metallic electrode. The sensor is cheap, easy to fabricate, lasts for several months, and is suitable for measuring air pressures in the range between 100 and 700 mmHg.
Resumo:
The aim of this study was to estimate the indoor and outdoor concentrations of fungal spores in the Metropolitan Area of Sao Paulo (MASP), collected at different sites in winter/spring and summer seasons. The techniques adopted included cultivation (samples collected with impactors) and microscopic enumeration (samples collected with impingers). The overall results showed total concentrations of fungal spores as high as 36,000 per cubic meter, with a large proportion of non culturable spores (around 91 per cent of the total). Penicillium sp. and Aspergillus sp. were the dominant species both indoors and outdoors, in all seasons tested, occurring in more than 30 per cent of homes at very high concentrations of culturable airborne fungi [colony forming units(CFU) m−3]. There was no significant difference between indoor and outdoor concentrations. The total fungal spore concentration found in winter was 19 per cent higher than that in summer. Heat and humidity were the main factors affecting fungal growth; however, a non-linear response to these factors was found. Thus, temperatures below 16°C and above 25°C caused a reduction in the concentration (CFU m−3) of airborne fungi, which fits with MASP climatalogy. The same pattern was observed for humidity, although not as clearly as with temperature given the usual high relative humidity (above 70 per cent) in the study area. These results are relevant for public health interventions that aim to reduce respiratory morbidity among susceptible populations
Resumo:
Introdução e objetivo: A exposição à luz natural tem efeitos relevantes no sistema de temporização biológica. Pode-se supor que essa exposição poderia promover um ajuste melhor entre os ritmos biológicos e os horários de início de trabalho entre trabalhadores diurnos de ambientes externos. O objetivo deste estudo foi comparar a matutinidade/vespertinidade e a relação entre o horário de trabalho real e o ideal em trabalhadores diurnos expostos a condições de iluminação distintas. Métodos: O estudo foi conduzido com dois grupos de trabalhadores (n=49) que residiam em uma área rural e tinham condições sociais similares. Um grupo trabalhava em ambiente interno (n=20, idade média 30,8 anos (21-50); desvio padrão=9,8) e o outro grupo trabalhava em ambiente externo (n=29, idade média 30,8 anos (17- 50); desvio padrão=10,0). Os trabalhadores preencheram um questionário de matutinidade/vespertinidade (MEQ). Foi realizada uma ANOVA de um fator com o intuito de comparar os escores do MEQ entre os dois grupos de trabalhadores. Resultados: Como esperado, o Grupo do Ambiente Externo (GAE) apresentou média de escores mais elevada que o Grupo do Ambiente Interno (GAI), o que significa uma tendência à matutinidade (GAE: 58,4±7,9; GAI; 47,4±6,4), com significância estatística (F=26,22; p<0,001). De acordo com os dados relatados em relação aos horários de trabalho, o GAE gostaria de atrasar seu horário de trabalho em 31 minutos, em média, enquanto que o GAI gostaria de atrasar em 96 minutos seu horário de trabalho (F=7,71; p<0,01). Conclusões: Os resultados desse estudo sugerem que a exposição à luz natural pode promover um ajuste melhor aos horários de início de trabalho matutinos
Resumo:
Background: The Brazilian Amazon has suffered impacts from non-sustainable economic development, especially owing to the expansion of agricultural commodities into forest areas. The Tangara da Serra region, located in the southern of the Legal Amazon, is characterized by non-mechanized sugar cane production. In addition, it lies on the dispersion path of the pollution plume generated by biomass burning. The aim of this study was to assess the genotoxic potential of the atmosphere in the Tangara da Serra region, using Tradescantia pallida as in situ bioindicator. Methods: The study was conducted during the dry and rainy seasons, where the plants were exposed to two types of exposure, active and passive. Results: The results showed that in all the sampling seasons, irrespective of exposure type, there was an increase in micronucleus frequency, compared to control and that it was statistically significant in the dry season. A strong and significant relationship was also observed between the increase in micronucleus incidence and the rise in fine particulate matter, and hospital morbidity from respiratory diseases in children. Conclusions: Based on the results, we demonstrated that pollutants generated by biomass burning in the Brazilian Amazon can induce genetic damage in test plants that was more prominent during dry season, and correlated with the level of particulates and elevated respiratory morbidity.