1000 resultados para Acartia danae, c5, length


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors present experimental results showing how the use of a high contrast femtosecond laser system allows better optimization of K emission from a Cu target. The shorter scale-length preformed plasma is better optimized for resonance absorption of the laser light when the laser is moved away from best focus. The experimental data show a central peak of K emission at tight focus with strong secondary peaks at large offset. The use of these secondary peaks results in a much reduced hard x-ray background and should lead to shorter K pulses than at tight focus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Density functional calculations, using B3LPY/6-31G(d) methods, have been used to investigate the conformations and vibrational (Raman) spectra of a series of long-chain, saturated fatty acid methyl esters (FAMEs) with the formula CH2nO2 (n = 5-21) and two series of unsaturated FAMEs. The calculations showed that the lowest energy conformer within the saturated FAMEs is the simple (all-trans) structure and, in general, it was possible to reproduce experimental data using calculations on only the all-trans conformer. The only exception was C6H12O2, where a second low-lying conformer had to be included in order to correctly simulate the experimental Raman spectrum. The objective of the work was to provide theoretical justification for the methods that are commonly used to determine the properties of the fats and oils, such as chain length and degree of unsaturation, from experimental Raman data. Here it is shown that the calculations reproduce the trends and calibration curves that are found experimentally and also allow the reasons for the failure of what would appear to be rational measurements to be understood. This work shows that although the assumption that each FAME can simply be treated as a collection of functional groups can be justified in some cases, many of the vibrational modes are complex motions of large sections of the molecules and thus would not be expected to show simple linear trends with changes in structure, such as increasing chain length and/or unsaturation. Simple linear trends obtained from experimental data may thus arise from cancellation of opposing effects, rather than reflecting an underlying simplicity.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Self-affine dehydrated colloidal deposits on fresh mica surfaces of the synthetic layered silicate 2:1 smectite clay laponite have been studied by means of atomic force microscopy (AFM). AFM images of these prepared assemblies of sol and gel aggregates have been analyzed both by means of standard AFM Fourier software and a wavelet method. The deposited surfaces show a persistence to antipersistent crossover with a clay concentration dependent crossover length. It is concluded that the crossover length is associated with aggregate size, and further that the persistent roughness at small length scales signals near compact clusters of fractal dimension three, whereas the antipersistent roughness at large length scales signals a sedimentation process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter investigates the optimum decision delay and tap-length of the finite-length decision feedback equalizer. First we show that, if the feedback filter (FBF) length N-b is equal to or larger than the channel memory upsilon and the decision delay Delta is smaller than the feedforward filter (FFF) length N-f, then only the first Delta + 1 elements of the FFF can be nonzero. Based on this result we prove that the maximum effective FBF length is equal to the channel memory upsilon, and if N-b greater than or equal to upsilon and N-f is long enough, the optimum decision delay that minimizes the MMSE is N-f - 1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modelling patient flow in health care systems is vital in understanding the system activity and may therefore prove to be useful in improving their functionality. An extensively used measure is the average length of stay which, although easy to calculate and quantify, is not considered appropriate when the distribution is very long-tailed. In fact, simple deterministic models are generally considered inadequate because of the necessity for models to reflect the complex, variable, dynamic and multidimensional nature of the systems. This paper focuses on modelling length of stay and flow of patients. An overview of such modelling techniques is provided, with particular attention to their impact and suitability in managing a hospital service.