992 resultados para ATLAS, Pixel Detector, ROD, LHC, CERN


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Book review of Atlas of Anatomy by Patrick W. Tank and Thomas R. Gest

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we propose a sparse signal modulation (SSM) method for precoded orthogonal frequency division multiplexing (OFDM) systems and study the signal detection. Although a receiver is able to exploit a path diversity gain with random precoding in OFDM, the complexity of the receiver is usually high as the orthogonality is not retained due to precoding. However, with SSM, we can derive a low-complexity detector that can provide reasonably good performances with a low sparsity ratio based on the notion of compressive sensing (CS). An important feature of a CS detector is that it can estimate SSM signals with a small fraction of the received signals over sub-carriers. This feature can allow us to build a low cost receiver with a small number of demodulators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The collection of the data for this volume formed part of the work of the European Science Foundation project on Writing National Histories. I was a member of the Research Team (1) which produced the volume. I also wrote two contributions for the Atlas. I collected the data and wrote the section on academic historians in Ireland. I also wrote a synthesis of the data on academic women historians in Europe, 1815-2005.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple circuit that is able to indicate if an injection-locked oscillator is in the locked condition by providing a ‘high’ or ‘low’ output is presented. The detector is compatible with most injection-locked oscillators as all that is required is access to the low-frequency bias circuit, with no direct access needed to the RF/microwave signals. To prove the universal nature of the lock detector it is successfully demonstrated practically for two scenarios: (i) a 1 GHz injection-locked VCO and (ii) a 60 GHz SiGe VCO MMIC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High Efficiency Video Coding (HEVC) is the most recent video codec coming after currently most popular H.264/MPEG4 codecs and has promising compression capabilities. It is conjectured that it will be a substitute for current video compression standards. However, to the best knowledge of the authors, none of the current video steganalysis methods designed or tested with HEVC video. In this paper, pixel domain steganography applied on HEVC video is targeted for the first time. Also, its the first paper that employs accordion unfolding transformation, which merges temporal and spatial correlation, in pixel domain video steganalysis. With help of the transformation, temporal correlation is incorporated into the system. Its demonstrated for three different feature sets that integrating temporal dependency substantially increased the detection accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As cryptographic implementations are increasingly subsumed as functional blocks within larger systems on chip, it becomes more difficult to identify the power consumption signatures of cryptographic operations amongst other unrelated processing activities. In addition, at higher clock frequencies, the current decay between successive processing rounds is only partial, making it more difficult to apply existing pattern matching techniques in side-channel analysis. We show however, through the use of a phase-sensitive detector, that power traces can be pre-processed to generate a filtered output which exhibits an enhanced round pattern, enabling the identification of locations on a device where encryption operations are occurring and also assisting with the re-alignment of power traces for side-channel attacks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Administration of biomacromolecular drugs in effective quantities from conventional vaginal rings is hampered by poor drug permeability in the polymers from which rings are commonly constructed. Here, we report the formulation development and testing of rod insert rings for sustained release of the candidate antiretroviral peptides T-1249 and JNJ54310516-AFP (JNJ peptide), both of which have potential as HIV microbicides. Rod inserts were prepared comprising antiviral peptides T-1249 or JNJ peptide in combination with a hydrophilic excipient (sodium chloride, sodium glutamate, lactose or zinc acetate) dispersed at different loadings within a medical grade silicone elastomer. The inserts were tested for weight change and swelling when immersed in simulated vaginal fluid (SVF). Dye migration into the inserts was also assessed visually over 28 days. In vitro release of T-1249 and JNJ peptide from rings containing various insert types was tested. Weight change and degree of swelling of rods immersed in SVF was dependent on the type and concentration of excipient present. The rods displayed the following rank order in terms of weight change: sodium glutamate > zinc acetate ≈ sodium chloride > lactose. The weight change and degree of swelling of the inserts did not correlate with the level of dye uptake observed. In vitro release of T-1249 was improved through addition of lactose, sodium chloride and sodium glutamate, while release of JNJ peptide was improved through addition of sodium chloride or sodium glutamate. Sustained release of hydrophobic peptides can be achieved using a rod insert ring design formulated to include a hydrophilic excipient. Release rates were dependent upon the type of excipient used. The degree of release improvement with different inserts partially reflects their ability to imbibe surrounding fluid and swell in aqueous environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lightweighting the preform to reduce material cost is possibly reaching its limit; key areas of the bottle however may deserve closer attention. The lack of material stretching at the bottle base insists on increased thickness to compensate for the impaired strength in this area. To improve this phenomenon, design of a novel stretch-rod that can mechanically stretch the preform tip during the ISBM process has been developed.

PETAL-ROD is a device that can be retrofitted to existing ISBM machines with minimum interruption to production rate, with the added benefit that material characteristics similar to the sidewall of the bottle can be achieved in the area of the base. Coupled with an optimized preform design, material weight saving can be improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter analyzes the performance of a low complexity detection scheme for a multi-carrier index keying (MCIK) with orthogonal frequency division multiplexing (OFDM) system over two-wave with diffused power (TWDP) fading channels. A closed-form expression for the average pairwise error probability (PEP) over TWDP fading channels is derived. This expression is used to analyze the performance of MCIK-OFDM in moderate, severe and extreme fading conditions. The presented results provide an insight on the performance of MCIK-OFDM for wireless communication systems that operate in enclosed metallic structures such as in-vehicular device-to-device (D2D) wireless networks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the PTW 1000SRS array with Octavius 4D phantom was characterised for FF and FFF beams. MU linearity, field size, dose rate, dose per pulse (DPP) response and dynamic conformal arc treatment accuracy of the 1000SRS array were assessed for 6MV, 6FFF and 10FFF beams using a Varian TrueBeam STx linac. The measurements were compared with a pinpoint IC, microdiamond IC and EBT3 Gafchromic film. Measured dose profiles and FWHMs were compared with film measurements. Verification of FFF volumetric modulated arc therapy (VMAT) clinical plans were assessed using gamma analysis with 3%/3 mm and 2%/2 mm tolerances (10% threshold). To assess the effect of cross calibration dose rate, clinical plans with different dose rates were delivered and analysed. Output factors agreed with film measurements to within 4.5% for fields between 0.5 and 1 cm and within 2.7% for field sizes between 1.5 and 10 cm and were highly correlated with the microdiamond IC detector. Field sizes measured with the 1000SRS array were within 0.5 mm of film measurements. A drop in response of up to 1.8%, 2.4% and 5.2% for 6MV, 6FFF and 10FFF beams respectively was observed with increasing nominal dose rate. With an increase in DPP, a drop of up to 1.7%, 2.4% and 4.2% was observed in 6MV, 6FFF and 10FFF respectively. The differences in dose following dynamic conformal arc deliveries were less than 1% (all energies) from calculated. Delivered VMAT plans showed an average pass percentage of 99.5(±0.8)% and 98.4(±3.4)% with 2%/2 mm criteria for 6FFF and 10FFF respectively. A drop to 97.7(±2.2)% and 88.4(±9.6)% were observed for 6FFF and 10FFF respectively when plans were delivered at the minimum dose rate and calibrated at the maximum dose rate. Calibration using a beam with the average dose rate of the plan may be an efficient method to overcome the dose rate effects observed by the 1000SRS array.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-carrier index keying (MCIK) is a recently developed transmission technique that exploits the sub-carrier indices as an additional degree of freedom for data transmission. This paper investigates the performance of a low complexity detection scheme with diversity reception for MCIK with orthogonal frequency division multiplexing (OFDM). For the performance evaluation, an exact and an approximate closed form expression for the pairwise error probability (PEP) of a greedy detector (GD) with maximal ratio combining (MRC) is derived. The presented results show that the performance of the GD is significantly improved when MRC diversity is employed. The proposed hybrid scheme is found to outperform maximum likelihood (ML) detection with a substantial reduction on the associated computational complexity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of computed tomography systems with energy resolving detectors is a current challenge in medical physics and biomedical engineering. A computed tomography system of this kind allows getting complementary informations relatively to conventional systems, that can help the medical diagnosis, being of great interest in medicine. The work described in this thesis is related to the development of a computed tomography system using micropattern gaseous detectors, which allow storing, simultaneously, information about the interaction position and the energy of each single photon that interacts with the detector. This kind of detectors has other advantages concerning the cost and characteristics of operation when compared with solid state detectors. Tomographic acquisitions were performed using a MicroHole & Strip Plate based detector, which allowed reconstructing cross-sectional images using energy windows, applying the energy weighting technique and performing multi-slice and tri-dimensional reconstructions. The contrast-to-noise ratio was improved by 31% by applying the energy weighting technique, comparing with the corresponding image obtained with the current medical systems. A prototype of a computed tomography with flexibility to change the detector was developed, making it possible to apply different detectors based on Thick-COBRA. Several images acquired with these detectors are presented and demonstrate their applicability in X-ray imaging. When operating in NeCH4, the detector allowed a charge gain of 8 104, an energy resolution of 20% (full width at half maximum at 8 keV), a count rate of 1 106 Hz/mm2, a very stable operation (gain fluctuations below 5%) and a spacial resolution of 1.2 mm for an energy photon of 3.6 keV. Operating the detector in pure Kr allowed increasing the detection efficiency and achieving a charge gain of 2 104, an energy resolution of 32% (full width at half maximum at 22 keV), a count rate of 1 105 Hz/mm2, very stable operation and a spatial resolution of 500 m. The software already existing in the group was improved and tools to correct geometric misalignments of the system were also developed. The reconstructions obtained after geometrical correction are free of artefacts due to the referred misalignments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This experimental study focuses on a detection system at the seismic station level that should have a similar role to the detection algorithms based on the ratio STA/LTA. We tested two types of neural network: Multi-Layer Perceptrons and Support Vector Machines, trained in supervised mode. The universe of data consisted of 2903 patterns extracted from records of the PVAQ station, of the seismography network of the Institute of Meteorology of Portugal. The spectral characteristics of the records and its variation in time were reflected in the input patterns, consisting in a set of values of power spectral density in selected frequencies, extracted from a spectro gram calculated over a segment of record of pre-determined duration. The universe of data was divided, with about 60% for the training and the remainder reserved for testing and validation. To ensure that all patterns in the universe of data were within the range of variation of the training set, we used an algorithm to separate the universe of data by hyper-convex polyhedrons, determining in this manner a set of patterns that have a mandatory part of the training set. Additionally, an active learning strategy was conducted, by iteratively incorporating poorly classified cases in the training set. The best results, in terms of sensitivity and selectivity in the whole data ranged between 98% and 100%. These results compare very favorably with the ones obtained by the existing detection system, 50%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A investigação desenvolvida neste estudo pretende conduzir a uma reflexão sobre a relação que se estabelece entre a geometria e o pensamento abstracto de mulheres berberes, maioritariamente analfabetas e que, até há bem pouco tempo (talvez ainda em algumas regiões rurais, mais isoladas, de Marrocos), viviam segregadas. Falamos, sim, desses berberes que chegaram e se instalaram nas montanhas de Marrocos, muito antes da chegada dos árabes e que, ainda hoje continuam a fazer história, deixando que o seu quotidiano, o seu modo de vida seja ditado pelo enquadramento numa paisagem magnífica, que dá azo a um tempo mais lento, mais contemplativo, mais devoto. Reflectir-se-á sobre a originalidade dos tapetes berberes, cujo produto final não está delineado, à partida, mas que tem a ver com uma concepção interior da obra, que promove a liberdade de criação destas mulheres. Procurar-se-á compreender o tapete como uma forma de arte doméstica, conceptual, que emerge de um pensamento que, sendo geométrico (universal), se torna abstracto ou só compreensível por um grupo restrito de iniciados.1 O tapete tornou-se o segredo destas mulheres. E só o é, porque nós (todos, à excepção das mulheres berberes) não o conseguimos entender. Falamos de um “código” que só é perceptível quando é conhecida a matriz do pensamento. Pode até conhecer-se a técnica e a estética dos tapetes, identificar-se as diferentes tipologias e os materiais utilizados, mas tornar-se-á impossível criá-los, como estas mulheres o fazem, sem planos pré-estabelecidos. É essa maneira de produzir, quase inata para estas mulheres, que está fora do nosso alcance lógico.