969 resultados para 4D Ultrasound
Resumo:
The determination of aminotranferases levels is very useful in the diagnosis of hepatopathies. In recent years, an elevated serum ALT level in blood donors has been associated with an increased risk of post-transfusion hepatitis (PTH). The purpose of the study was to research the factors associated with elevated ALT levels in a cohort of voluntary blood donors and to evaluate the relationship between increased ALT levels and the development of hepatitis C (HCV) infection. 166 volunteer blood donors with elevated ALT at the time of their first donation were studied. All of the donors were questioned about previous hepatopathies, exposure to hepatitis, exposure to chemicals, use of medication or drugs, sexual behaviour, contact with blood or secretions and their intake of alcohol. Every three months, the serum levels of AST, ALT, alkaline phosphatase, gamma glutamyl transpeptidase, cholesterol, triglyceride and glycemia are assessed over a two year follow-up. The serum thyroid hormone levels as well as the presence of auto-antibodies were also measured. Abdominal ultrasound was performed in all patients with persistently elevated ALT or AST levels. A needle biopsy of liver was performed in 9 donors without definite diagnostic after medical investigation. The presence of anti-HCV antibodies in 116 donors were assayed again the first clinical evaluation. At the end of follow-up period (2 years later) 71 donors were tested again for the presence of anti-HCV antibodies. None of donors resulted positive for hepatitis B or hepatitis C markers during the follow-up. Of the 116 donors, 101 (87%) had persistently elevated ALT serum levels during the follow-up. Obesity and alcoholism were the principal conditions related to elevated ALT serum levels in 91/101 (90.1%) donors. Hypertriglyceridemia, hypercholesterolemia, hypothyroidism and diabetes mellitus also were associated with increased ALT levels. Only 1/101 (0.9%) had mild chronic active non A-G viral hepatitis and 3/101 (2.9%) had liver biopsy with non-specific reactive hepatitis. The determination of ALT levels was not useful to detect donors infected with HCV at donation in Brazil, including the initial seronegative anti-HCV phase.
Resumo:
Thesis submitted to the Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia, for the degree of Doctor of Philosophy in Biochemistry
Resumo:
We report the second case of infection with Chromobacterium violaceum that occurred in Brazil. A farm worker living in the State of São Paulo presented fever and severe abdominal pain for four days. At hospitalization the patient was in a toxemic state and had a distended and painful abdomen. Chest X-ray and abdominal ultrasound revealed bilateral pneumonia and hypoechoic areas in the liver. The patient developed failure of multiple organs and died a few hours later. Blood culture led to isolation of C. violaceum resistant to ampicillin and cephalosporins and sensitive to chloramphenicol, tetracyclin, aminoglicosydes, and ciprofloxacin. Autopsy revealed pulmonary microabscesses and multiple abscesses in the liver. The major features of this case are generally observed in infections by C. violaceum: rapid clinical course, multiple visceral abscesses, and high mortality. Because of the antimicrobial resistance profile of this Gram-negative bacillus, for appropriate empirical antibiotic therapy it is important to consider chromobacteriosis in the differential diagnosis of severe community infections in Brazil.
Resumo:
Between 1992 and 1997, 790 blood donors with anti-HCV EIA-2 strongly reagent (relationship between the sample optical density/cut-off > 3) detected at the blood bank serological screening, were evaluated in ambulatory environment. They were all negative for Chagas disease, syphilis, hepatitis B (HBsAg) and AIDS. Blood samples were collected at the first ambulatorial evaluation, for hemogram, biochemical tests and new serological tests for HCV (anti-HCV EIA-2). In blood samples of 226 repeatedly reagent anti-HCV EIA-2 blood donors, supplementary "immunoblot" test for HCV (RIBA-2) was used. In 209 donors, the presence of HCV-RNA was investigated by the PCR test. The abdominal ultrasonography was realized in 366 donors. In 269 patients liver biopsy was performed for the histopathological study. The follow-up of blood donors showed that 95.6% were repeatedly EIA-2 reagent, 94% were symptomless and denied any hepatitis history, with only 2% mentioning previous jaundice. In 47% of this population at least one risk factor has been detected for the HCV transmission, the use of intravenous drugs being the main one (27.8%). Blood transfusion was the second factor for HCV transmission (27.2%). Hepatomegaly was detected in 54% of the cases. Splenomegaly and signs of portal hypertension have seldom been found in the physical examination, indicating a low degree of hepatic compromising in HCV. Abdominal ultrasound showed alterations in 65% of the subjects, being the steatosis the most frequent (50%). In 83.5% of the donors submitted to the liver biopsy, the histopathological exam showed the presence of chronic hepatitis, usually classified as active (89%) with mild or moderate grade in most of the cases (99.5%). The histopathological exam of the liver was normal in 1.5% of blood donors. The RIBA-2 test and the HCV-RNA investigation by PCR were positive in respectively 91.6 and 75% of the anti-HCV EIA-2 reagent donors. The HCV-RNA research was positive in 82% of the RIBA-2 positive subjects, in 37.5% of the indeterminate RIBA-2 donors and in 9% of the negative RIBA-2 donors. Chronic hepatitis has also been observed in 50% of the histopathological exams of the anti-HCV EIA-2 reagent donors which were indeterminate RIBA-2. Among 18 blood donors with minimal changes histopathological exam 11 (61%) were HCV-RNA positive. Our blood donors anti-HCV reagent generally had clinical, laboratorial and histopathological features observed in patients with chronic HCV hepatitis and a high proportion could be identified in interviews and medical evaluation realized in blood blanks. Generally, these HCV infected donors are identified and discharged only by the serological tests results.
Resumo:
RESUMO: Desenho do estudo: Estudo quantitativo, experimental prospectivo de factor único, desenho pré-teste, pós-teste. Objectivos: Determinar a efectividade da ecografia em tempo real, como Informação de Retorno Extrínseca Visual Ecográfica (IRE-VE) na performance do transverso do abdómen (TrA), em sujeitos saudáveis; analisar eventuais diferenças entre a IRE-VE e a Informação de Retorno Extrínseca Verbal Clínica (IRE-VC); medir a performance da musculatura abdominal, através das diferenças na espessura dos músculos TrA e oblíquo interno (OI) e deslizamento do TrA, em repouso e em contracção. Enquadramento: A maioria dos indivíduos não tem conhecimentos nem consciência do contributo de uma boa performance do TrA para a estabilidade da coluna lombar. Vários estudos recentes se têm dedicado a este assunto, tendo sido mostrado o importante contributo da ecografia como Informação de Retorno Extrínseca (IRE). Uma vez que o TrA e o OI contribuem para a estabilidade lombo pélvica, e que a aprendizagem do seu controlo motor é essencial para a recuperação da função, torna-se relevante clarificar o contributo da informação de retorno na primeira fase da aprendizagem da performance desses músculos, bem como encontrar as melhores estratégias para a sua realização. A ecografia foi o instrumento escolhido para servir esse objectivo. Métodos: Participaram no estudo 75 sujeitos, sem queixas lombares, com idades compreendidas entre os 18 e os 38 anos com um valor médio de 21,9 anos (±4,03), divididos aleatoriamente em três grupos com uma tarefa comum: a “Manobra do Transverso”, em que um grupo não recebeu IRE (GC), outro recebeu IRE verbal clínica e palpatória (GIRE-VC) e ooutro recebeu IRE visual ecográfica (GIRE-VE). Para efeitos de análise da contracção da musculatura abdominal, foram estudadas a espessura dos músculos TrA e OI e o deslizamento do TrA, visualizados em imagens ecográficas em tempo real, e congeladas para medição em diferido. Estes procedimentos foram apurados num estudo piloto de fidedignidade das medições em causa. Quanto à abordagem estatística das variáveis de performance muscular foi realizada uma análise da variância simples paramétrica para amostras independentes e um teste para a diferença de médias para amostras emparelhadas. Resultados: Observamos que no GC, a ausência de IRE cursou com uma performance idêntica nos dois momentos de avaliação e que nos dois grupos com IRE, das variáveis de performance, é significativamente diferente a contracção do TrA, para uma diferença de 1,95 mm no GIRE-VE (p=0,000) e de 0,84 mm no GIRE-VC (p=0,000). Ao comparar os grupos entre si houve diferenças no limiar da significância (p=0,056) para uma melhor contracção do TrA no GIRE-VE. As outras variáveis, contracção do OI e deslizamento do TrA, não revelaram efeito relacionado com a IRE em nenhum dos grupos. Conclusão: Dos resultados obtidos, podemos concluir que a IRE-VE, quando usada isoladamente, na Manobra do Transverso provoca um maior aumento na espessura do TrA, quando comparada com a IRE-VC . O uso da ecografia mostrou ser efectivo na facilitação da performance da Manobra do Transverso em sujeitos saudáveis.---------------------ABSTRACT: Study Design: Single Factor Experimental Design: Pre-Test Post-test Control Group Design. Objectives: To measure the contribution of different types of biofeedack on Transversus Abdominis (TrA) and Internal Oblique (IO) performance through changes in thickness and lateral slide of TrA anterior fascia during abdominal hollowing exercise (AHE). Background: Increasingly clinicians are using real-time ultrasound imaging as a form of supplementing feedback when teaching trunk stabilization exercises to patients; however, there has been no evidence of its effectiveness when used alone. Material and Methods: Seventy-five healthy subjects were divided randomly into 3 groups that received: group 1, no feedback; group 2, verbal and palpatory feedback, and group 3, realtime ultrasound feedback. The TrA and IO performance of each subject was twice assessed (before and after receiving feedback) when performing the AHE in a supine hook-lying position. Analysis of variance and T-test were used for the independent and paired samples, respectively, to determine significant changes in the performance of TrA and IO, based on intra and inter group analysis. Results: Group 1 had no differences between moments; group 2 had significant differences concerning TrA thickness (p=0,000) to a 0,84 mm thickness difference; group 3 had significant differences concerning TrA thickness (p=0,000) to a 1,94 mm difference; The ability to perform the AHE differed only among group 3 and group 1 (p=0.056), and only for changes in thickness of TrA muscle. No differences among groups were found neither for the lateral slide of TrA anterior fascia, nor for the internal oblique thickness. Conclusion: From the results of this study we conclude that real-time ultrasound feedback, when used alone during an AHE, can have a larger increase in TrA thickness when compared to verbal and palpatory feedback. The use of real time ultrasound showed to be effective as a feedback tool to facilitate the performance of the AHE in a supine hook-lying position in healthy subjects.
Resumo:
RESUMO: O presente estudo teve como objectivo avaliar a efectividade de um programa de intervenção de fisioterapia comparativamente ao tratamento conservador (calor húmido, ultra-som e massagem), relativamente à dor e capacidade funcional, no utente idoso com doença osteoarticular do joelho. A amostra foi aleatória, tendo sido seleccionados 20 utentes que respeitaram os critérios de inclusão, e que foram distribuídos aleatoriamente pelos dois grupos de tratamento, 9 no grupo A (experimental) e 11 no grupo B (controle). Todos os utentes deram o seu consentimento informado. Trata-se de um estudo experimental, controlado aleatorizado (RCT). A intervenção em estudo consistiu em 15 sessões de tratamento individuais, efectuadas 3 vezes por semana. O programa terapêutico efectuado pelo grupo A incluiu o tratamento conservador (20 minutos calor húmido, 5 minutos ultra-som (contínuo; 1,5W/cm2) e aproximadamente 10 minutos de massagem local) e o protocolo de exercícios terapêuticos em estudo. Este protocolo de exercícios foi progredindo semanalmente em termos da sua intensidade. Os utentes do Grupo B efectuaram apenas o tratamento conservador (tal como no grupo A). Para avaliar a dor e a capacidade funcional foi utilizado o Questionário knee Injury and Osteoarthritis Outcome Score. A análise dos resultados foi realizada através dos testes Mann-Whitney e Kruskal-Wallis para a comparação entre grupos. Os resultados sugerem não haver diferenças estatisticamente significativos entre os grupos, embora o grupo de controle tenha obtido melhores resultados. O grupo B apresentou uma diminuição da dor de 17,33, comparativamente aos valores de -3,00 no grupo A (p=0,101), e melhoria da capacidade funcional de 13,00, mantendo-se a capacidade funcional igual, no grupo A (0,00) p=0,080). Estes resultados parecem sugerir que não há diferenças significativas entre as duas modalidades de intervenção, realçando a necessidade de continuar a investigar este protocolo de exercícios e a sua efectividade.-----------------ABSTRACT: The aims of this study was to evaluate the effectiveness of a treatment program compared with conventional treatment (post hoots, ultrasound and massage), for the outcomes pain and functional ability in elderly with knee osteoarthritis. The sample was non-probability, and 20 patients have been selected that fulfilled the criteria for inclusion and who were randomly assigned to the two treatment groups, in group A and 11 in group B. All of the patients gave their informed consent. This is an experimental, randomized controlled trial (RCT) with blinded assessment, of comparative design. This study protocol program was carry out in 15 individual treatment sessions, 3x per week. The therapeutic program made by group A consisted of the performance of conservative treatment: 20 minutes of hot packs, 5 minutes of ultrasound (continuous, 1.5 W/cm2) and 10 minutes of massage plus the exercise protocol therapy consisted of: isometric exercises of quadriceps contractions, muscle strengthening for knee and aerobic training. This exercise protocol was progressing every week in terms of its intensity. The users in Group B, only made the conservative treatment (such as in group A). In this study there were evaluated the pain and functional capacity, assessed by questionnaire knee Injury Osteoarthritis Outcome Score. For comparison between groups were used Mann-Whitney and Kruskal-Wallis tests. The results revealed that in group B was that it obtained better results, although they are not statistical significance. The group B show a decrease in pain of 17.33 compared to -3.00 in group A (p = 0.101), and improved capacity functional of 13.00, keeping in group A (0.00) (p = 0.080). However, the differences are not statistically significant. These results show that there are not statistically significant in both treatments, but more studies are needed.
Resumo:
Perinephric and renal abscesses are rare in childhood, but they must be remembered in the differential diagnosis of fever and abdominal or flank pain. This paper reports three cases whose solution was found after clinical and surgical treatment. The importance of ultrasound and computerized tomography (CT) in prompt diagnosis is highlighted in this work. The use of these methods along the improved antimicrobial therapy may result in decrease in mortality due to this pathology.
Resumo:
Dissertation for the degree of Doctor of Philosophy in Physics
Resumo:
Objective: To compare measurements of the upper arm cross-sectional areas (total arm area,arm muscle area, and arm fat area of healthy neonates) as calculated using anthropometry with the values obtained by ultrasonography. Materials and methods: This study was performed on 60 consecutively born healthy neonates: gestational age (mean6SD) 39.661.2 weeks, birth weight 3287.16307.7 g, 27 males (45%) and 33 females (55%). Mid-arm circumference and tricipital skinfold thickness measurements were taken on the left upper mid-arm according to the conventional anthropometric method to calculate total arm area, arm muscle area and arm fat area. The ultrasound evaluation was performed at the same arm location using a Toshiba sonolayer SSA-250AÒ, which allows the calculation of the total arm area, arm muscle area and arm fat area by the number of pixels enclosed in the plotted areas. Statistical analysis: whenever appropriate, parametric and non-parametric tests were used in order to compare measurements of paired samples and of groups of samples. Results: No significant differences between males and females were found in any evaluated measurements, estimated either by anthropometry or by ultrasound. Also the median of total arm area did not differ significantly with either method (P50.337). Although there is evidence of concordance of the total arm area measurements (r50.68, 95% CI: 0.55–0.77) the two methods of measurement differed for arm muscle area and arm fat area. The estimated median of measurements by ultrasound for arm muscle area were significantly lower than those estimated by the anthropometric method, which differed by as much as 111% (P,0.001). The estimated median ultrasound measurement of the arm fat was higher than the anthropometric arm fat area by as much as 31% (P,0.001). Conclusion: Compared with ultrasound measurements using skinfold measurements and mid-arm circumference without further correction may lead to overestimation of the cross-sectional area of muscle and underestimation of the cross-sectional fat area. The correlation between the two methods could be interpreted as an indication for further search of correction factors in the equations.