977 resultados para tastiera virtuale Android Arduino Due virtual keyboard


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A semi-phenomenological molecular model is presented, which is capable of describing with the use of analytical formulae, the wideband dielectric(1) and far-infrared spectra of ordinary and heavy water. In the model the vector of a dipole moment is presented as a sum of two components. The absolute value of the first one is constant; the second one changes harmonically with time. The key aspect of this work is consideration of FIR spectra due to the second component. In the context of the modified hybrid model presented in the work, reorientation of the dipoles in the rectangular potential well is considered, as a result of which the librational (near 700 cm (-1)) and translational (near 200 cm (-1)) absorption bands and the microwave Debye relaxation spectrum arise. It is shown that the time-dependent part of a dipole moment contributes most to the translational band, the relevant mechanism is taken to be stretching vibration of the H-bonded molecules. Previous linear-response molecular models were unsuccessful in describing this band (in heavy water) in terms of the complex dielectric permittivity. The spatial and time scales characteristic of water are estimated. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare sperm yields, apoptotic indices, and sperm DNA fragmentation from vasectomized men and fertile men undergoing vasectomy.

Design: Testicular biopsies from vasectomized (n 26) and fertile men (n 46), were milked to calculate sperm/gram and also formalin-?xed to determine the numbers of developing sperm and incidence and intensities of testicular FasL, Fas, Bax, and Bcl-2. Testicular sperm DNA fragmentation was assessed using the alkaline Comet assay.

Setting: An ART unit.

Patient(s): Twenty-six men attending for intracytoplasmic sperm injection (ICSI) and 46 men attending for vasectomies.

Main Outcome Measure(s): Spermatocyte, spermatid and sperm yields, Fas, FasL, and Bax staining.

Result(s): Sperm yields from men vasectomized 5 years previously were markedly reduced compared to fertile men. Increased intensities of FasL and Bax staining were observed in the seminiferous tubules of vasectomy men. FasL positivity (percentage) also increased in Sertoli cells, and both FasL and Fas positivity (percentage) increased in primary spermatocytes and round spermatids of vasectomized men. Sperm DNA fragmentation, an end point marker of apoptosis, increased signi?cantly in vasectomized men compared to fertile men.

Conclusion(s): Reduced sperm yields after vasectomy are associated with increased apoptosis through the Fas–FasL and Bax pathways. Sperm after vasectomy displayed increased DNA fragmentation. (Fertil Steril 2007;87:834–41. ©2007 by American Society for Reproductive Medicine.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Investigating a recently developed Cushing Syndrome, we diagnosed in a 47-year-old woman an ectopic ACTH syndrome due to a metastatic carcinoid tumor, most likely a thymic carcinoid tumor. Combined therapy with sandostatin and nizoral and later on with sandostatin, metopirone and orimeten, was not able to suppress the hypercortisolism. A few weeks after surgical adrenalectomy, clinical deterioration ensued, culminating in the patient's death 7 months after diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: Radiotherapy is widely used to palliate local symptoms in non-small-cell lung cancer. Using conventional X-ray simulation, it is often difficult to accurately localize the extent of the tumour. We report a randomized, double blind trial comparing target localization with conventional and virtual simulation.Methods: Eighty-six patients underwent both conventional and virtual simulation. The conventional simulator films were compared with digitally reconstructed radiographs (DRRs) produced from the computed tomography (CT) data. The treatment fields defined by the clinicians using each modality were compared in terms of field area, position and the implications for target coverage.Results: Comparing fields defined by each study arm, there was a major mis-match in coverage between fields in 66.2% of cases, and a complete match in only 5.2% of cases. In 82.4% of cases, conventional simulator fields were larger (mean 24.5+/-5.1% (95% confidence interval)) than CT-localized fields, potentially contributing to a mean target under-coverage of 16.4+/-3.5% and normal tissue over-coverage of 25.4+/-4.2%.Conclusions: CT localization and virtual simulation allow more accurate definition of the target volume. This could enable a reduction in geographical misses, while also reducing treatment-related toxicity.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: Currently, optimal use of virtual simulation for all treatment sites is not entirely clear. This study presents data to identify specific patient groups for whom conventional simulation may be completely eliminated and replaced by virtual simulation. Sampling and method: Two hundred and sixty patients were recruited from four treatment sites (head and neck, breast, pelvis, and thorax). Patients were randomly assigned to be treated using the usual treatment process involving conventional simulation, or a treatment process differing only in the replacement of conventional plan verification with virtual verification. Data were collected on set-up accuracy at verification, and the number of unsatisfactory verifications requiring a return to the conventional simulator. A micro-economic costing analysis was also undertaken, whereby data for each treatment process episode were also collected: number and grade of staff present, and the time for each treatment episode. Results: The study shows no statistically significant difference in the number of returns to the conventional simulator for each site and study arm. Image registration data show similar quality of verification for each study arm. The micro-costing data show no statistical difference between the virtual and conventional simulation processes. Conclusions: At our institution, virtual simulation including virtual verification for the sites investigated presents no disadvantage compared to conventional simulation.