974 resultados para speed reduction
Resumo:
This paper presents the application of advanced compact models of the IGBT and PIN diode to the full electrothermal system simulation of a hybrid electric vehicle converter using a look-up table of device losses. The Fourier-based solution model is used, which takes account of features such as local lifetime control and field-stop technology. Device and circuit parameters are extracted from experimental waveforms and device structural data. Matching of the switching waveforms and the resulting generation of the look-up table is presented. An example of the use of the look-up tables in simulation of inverter device temperatures is also given, for a hypothetical electric vehicle subjected to an urban driving cycle. © 2006 IEEE.
Resumo:
The importance of metal coating technologies drives the continuous improvement of metal deposition techniques for application in a wide range of industrial sectors. This work presents the foundations of a new process technology for the deposition of titanium coatings on steel tube substrates using supersonic powder streams and impact site laser heating, known as Supersonic Laser Deposition (SLD). Metallic deposits are obtained under appropriate impact conditions without the need for exceeding the melting point of the deposited material or substrate leading to improved coating quality. Details of the experimental approach are presented along with the general characteristics of the titanium coating produced using this novel coatings method. © 2011 Elsevier B.V. All rights reserved.
Resumo:
The effects of turbulent Reynolds number on the statistical behaviour of the displacement speed have been studied using three-dimensional Direct Numerical Simulation of statistically planar turbulent premixed flames. The probability of finding negative values of the displacement speed is found to increase with increasing turbulent Reynolds number when the Damkhler number is held constant. It has been shown that the statistical behaviour of the Surface Density Function, and its strain rate and curvature dependence, plays a key role in determining the response of the different components of displacement speed. Increasing the turbulent Reynolds number is shown to reduce the strength of the correlations between tangential strain rate and dilatation rate with curvature, although the qualitative nature of the correlations remains unaffected. The dependence of displacement speed on strain rate and curvature is found to weaken with increasing turbulent Reynolds number when either Damkhler or Karlovitz number is held constant, but the qualitative nature of the correlation remains unaltered. The implications of turbulent Reynolds number effects in the context of Flame Surface Density (FSD) modelling have also been addressed, with emphasis on the influence of displacement speed on the curvature and propagation terms in the FSD balance equation. © 2011 Nilanjan Chakraborty et al.
Resumo:
Targets to cut 2050 CO2 emissions in the steel and aluminium sectors by 50%, whilst demand is expected to double, cannot be met by energy efficiency measures alone, so options that reduce total demand for liquid metal production must also be considered. Such reductions could occur through reduced demand for final goods (for instance by life extension), reduced demand for material use in each product (for instance by lightweight design) or reduced demand for material to make existing products. The last option, improving the yield of manufacturing processes from liquid metal to final product, is attractive in being invisible to the final customer, but has had little attention to date. Accordingly this paper aims to provide an estimate of the potential to make existing products with less liquid metal production. Yield ratios have been measured for five case study products, through a series of detailed factory visits, along each supply chain. The results of these studies, presented on graphs of cumulative energy against yield, demonstrate how the embodied energy in final products may be up to 15 times greater than the energy required to make liquid metal, due to yield losses. A top-down evaluation of the global flows of steel and aluminium showed that 26% of liquid steel and 41% of liquid aluminium produced does not make it into final products, but is diverted as process scrap and recycled. Reducing scrap substitutes production by recycling and could reduce total energy use by 17% and 6% and total CO 2 emissions by 16% and 7% for the steel and aluminium industries respectively, using forming and fabrication energy values from the case studies. The abatement potential of process scrap elimination is similar in magnitude to worldwide implementation of best available standards of energy efficiency and demonstrates how decreasing the recycled content may sometimes result in emission reductions. Evidence from the case studies suggests that whilst most companies are aware of their own yield ratios, few, if any, are fully aware of cumulative losses along their whole supply chain. Addressing yield losses requires this awareness to motivate collaborative approaches to improvement. © 2011 Elsevier B.V. All rights reserved.
Resumo:
A receding horizon steering controller is presented, capable of pushing an oversteering nonlinear vehicle model to its handling limit while travelling at constant forward speed. The controller is able to optimise the vehicle path, using a computationally efficient and robust technique, so that the vehicle progression along a track is maximised as a function of time. The resultant method forms part of the solution to the motor racing objective of minimising lap time. © 2011 AACC American Automatic Control Council.
Resumo:
Freshwater giant prawn, Macrobrachium rosenbergii fry produced during late season can not withstand low temperature thus the prawn culture programme during winter is hampered. To overcome this problem, late season (August-September) prawn juveniles (0.9-6.8 g) were stocked at a density of 1.43 to 3.57/square meter in 350-476 square-meter ponds in Pabna and Mymensingh districts during October 2000 and cultured till May 2001. Monthly average water temperature during the winter months (December-February) varied from 16 to 22 °C and gradually increased to 32 °C in May. The prawn fry showed fast growth rate and attained an average weight of 60-70 g within eight months including three winter months. Growth compensation was observed during summer months. Survival rate was 60-79%. After extrapolation of the present growth rate more than 1,600 kg/ha production can be achieved in better-managed ponds. Extrapolated cost of production was Tk. 268,000 and 200,000 Tk./ha in two best ponds, sale value was Tk. 644,9146 [sic] and 528,466 and gross profit was Tk. 376,000-410,000, suggesting a higher economic feasibility of farming freshwater prawn with over-wintered juveniles.
Resumo:
Three dimensional, fully compressible direct numerical simulations (DNS) of premixed turbulent flames are carried out in a V-flame configuration. The governing equations and the numerical implementation are described in detail, including modifications made to the Navier-Stokes Characteristic Boundary Conditions (NSCBC) to accommodate the steep transverse velocity and composition gradients generated when the flame crosses the boundary. Three cases, at turbulence intensities, u′/sL, of 1, 2, and 6 are considered. The influence of the flame holder on downstream flame properties is assessed through the distributions of the surface-conditioned displacement speed, curvature and tangential strain rates, and compared to data from similarly processed planar flames. The distributions are found to be indistinguishable from planar flames for distances greater than about 17δth downstream of the flame holder, where δth is the laminar flame thermal thickness. Favre mean fields are constructed, and the growth of the mean flame brush is found to be well described by simple Taylor type diffusion. The turbulent flame speed, sT is evaluated from an expression describing the propagation speed of an isosurface of the mean reaction progress variable c̃ in terms of the imbalance between the mean reactive, diffusive, and turbulent fluxes within the flame brush. The results are compared to the consumption speed, sC, calculated from the integral of the mean reaction rate, and to the predictions of a recently developed flame speed model (Kolla et al., Combust Sci Technol 181(3):518-535, 2009). The model predictions are improved in all cases by including the effects of mean molecular diffusion, and the overall agreement is good for the higher turbulence intensity cases once the tangential convective flux of c̃ is taken into account. © 2010 Springer Science+Business Media B.V.
Resumo:
One of the most promising prophylactic agents being tested to control Penaeus monodon larval diseases is furanace (6-hydroxymethyl-2 2(5-nitro-2-furyl) vinyl pyridine). To evaluate further its suitability as a chemotherapeutic agent, its effects on the population growth of Chaetoceros calcitrans, the diatom used as feed for the zoeal stages, was examined. Chaetoceros populations of uniform density (initial density in all runs: 130-141x10 SUP-3 cells /ml) were placed in nine white, circular (382 sq cm), plastic basins. The physio-chemical characteristics of the culture water were as follows: salinity, 28 . 5-30 . 0 ppt; pH, 8 . 62-8 . 72; temperature, 23-25 . 5 degree C; dissolved oxygen, 7 . 1-9 . 3 ppm; nitrate, 0 . 03-0 . 07 ppm; and ammonia, 0 . 005-0 . 03 ppm. Preweighed furanace granules were dissolved in the culture water, with resulting concentrations of 1 and 2 mg/l (3 replicates each). A set of replicates without furanace served as the control. Population counts of the diatom were taken after 2, 4, 6, 8, and 10 hr exposures. After 4 hr, the population decreased in all three levels. The population in 2 mg/l furanace showed the lowest count and that in control the highest. The population means are not statistically different from one another. The results of the study show that the furanace causes reductions in Chaetoceros population at all durations of exposure.
Resumo:
This article investigates how to use UK probabilistic climate-change projections (UKCP09) in rigorous building energy analysis. Two office buildings (deep plan and shallow plan) are used as case studies to demonstrate the application of UKCP09. Three different methods for reducing the computational demands are explored: statistical reduction (Finkelstein-Schafer [F-S] statistics), simplification using degree-day theory and the use of metamodels. The first method, which is based on an established technique, can be used as reference because it provides the most accurate information. However, it is necessary to automatically choose weather files based on F-S statistic by using computer programming language because thousands of weather files created from UKCP09 weather generator need to be processed. A combination of the second (degree-day theory) and third method (metamodels) requires only a relatively small number of simulation runs, but still provides valuable information to further implement the uncertainty and sensitivity analyses. The article also demonstrates how grid computing can be used to speed up the calculation for many independent EnergyPlus models by harnessing the processing power of idle desktop computers. © 2011 International Building Performance Simulation Association (IBPSA).
Resumo:
This paper deals with the experimental evaluation of a flow analysis system based on the integration between an under-resolved Navier-Stokes simulation and experimental measurements with the mechanism of feedback (referred to as Measurement-Integrated simulation), applied to the case of a planar turbulent co-flowing jet. The experiments are performed with inner-to-outer-jet velocity ratio around 2 and the Reynolds number based on the inner-jet heights about 10000. The measurement system is a high-speed PIV, which provides time-resolved data of the flow-field, on a field of view which extends to 20 jet heights downstream the jet outlet. The experimental data can thus be used both for providing the feedback data for the simulations and for validation of the MI-simulations over a wide region. The effect of reduced data-rate and spatial extent of the feedback (i.e. measurements are not available at each simulation time-step or discretization point) was investigated. At first simulations were run with full information in order to obtain an upper limit of the MI-simulations performance. The results show the potential of this methodology of reproducing first and second order statistics of the turbulent flow with good accuracy. Then, to deal with the reduced data different feedback strategies were tested. It was found that for small data-rate reduction the results are basically equivalent to the case of full-information feedback but as the feedback data-rate is reduced further the error increases and tend to be localized in regions of high turbulent activity. Moreover, it is found that the spatial distribution of the error looks qualitatively different for different feedback strategies. Feedback gain distributions calculated by optimal control theory are presented and proposed as a mean to make it possible to perform MI-simulations based on localized measurements only. So far, we have not been able to low error between measurements and simulations by using these gain distributions.
Resumo:
Four size groups of milkfish were tested, 4-18 g, 20-34 g, 35-95 g and 200-300 g. A number of fish from each group were placed separately in identical 1.2 m2 wooden tanks containing seawater filled up to 30 cm depth. The aggregate weight of fish per size group was approximately 1 kg. The fish were held for 72 h, fed with lab-lab and provided with continuous aeration to allow recovery from stress during transport and handling. After the recovery period, aeration was stopped and 200 g of the fine rice bran was spread over the water in each tank creating a film of bran particles on the water surface. This was designed to speed up depletion of dissolved oxygen considering the combined effects of the screening-off of sunlight, the reduction of air-water interface and the breakdown of the bran particles. It is probable that stress on milkfish in brackishwater ponds could start when oxygen level drops to about 1.4 ppm. A further decrease to 0.04 ppm could produce a total kill of all specimens above 4 grams with marketable size and bigger size fish dying first.