998 resultados para silicon radiation detector


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infrared multilayer interference filters have been used extensively in satellite radiometers for about 15 years. Filters manufactured by the University of Reading have been used in Nimbus 5, 6, and 7, TIROS N, and the Pioneer Venus orbiter. The ability of the filters to withstand the space environment in these applications is critical; if degradation takes place, the effects would range from worsening of signal-to-noise performance to complete system failure. An experiment on the LDEF will enable the filters, for the first time, to be subjected to authoritative spectral measurements following space exposure to ascertain their suitability for spacecraft use and to permit an understanding of degradation mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies have shown that natural ultraviolet (UV) radiation increases secondary products such as phenolics but can significantly inhibit biomass accumulation in lettuce plants. In the work presented here, the effect of UV radiation on phenolic concentration and biomass accumulation was assessed in relation to photosynthetic performance in red and green lettuce types. Lettuce plants in polythene clad tunnels were exposed to either ambient (UV transparent film) or UV-free conditions (UV blocking film). The study tested whether growth reduction in lettuce plants exposed to natural UV radiation is because of inhibition of photosynthesis by direct damage to the photosynthetic apparatus or by internal shading by anthocyanins. Ambient levels of UV radiation did not limit the efficiency of photosynthesis suggesting that phenolic compounds may effectively protect the photosynthetic apparatus. Growth inhibition does, however, occur in red lettuce and could be explained by the high metabolic cost of phenolic compounds for UV protection. From a commercial perspective, UV transparent and UV blocking films offer opportunities because, in combination, they could increase plant quality as well as productivity. Growing plants continuously under a UV blocking film, and then 6 days before the final harvest transferring them to a UV transparent film, showed that high yields and high phytochemical content can be achieved complementarily.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A three-shot multiuser detector is proposed for the reverse link of asynchronous DS/CDMA systems. By taking advantage of the preceding (already reconstructed) bit and the matched filter output for the following two bits, the coupling between temporally adjacent bits (TABs, which always exists for asynchronous systems) is cancelled in a three step fashion. The obtained detector has several useful advantages over existing schemes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

All the orthogonal space-time block coding (O-STBC) schemes are based on the following assumption: the channel remains static over the entire length of the codeword. However, time selective fading channels do exist, and in many cases the conventional O-STBC detectors can suffer from a large error floor in the high signal-to-noise ratio (SNR) cases. This paper addresses such an issue by introducing a parallel interference cancellation (PIC) based detector for the Gi coded systems (i=3 and 4).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A bit-level processing (BLP) based linear CDMA detector is derived following the principle of minimum variance distortionless response (MVDR). The combining taps for the MVDR detector are determined from (1) the covariance matrix of the matched filter output, and (2) the corresponding row (or column) of the user correlation matrix. Due to the interference suppression capability of MVDR and the fact that no inversion of the user correlation matrix is involved, the influence of the synchronisation errors is greatly reduced. The detector performance is demonstrated via computer simulations (both synchronisation errors and intercell interference are considered).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a three-shot improvement scheme for the hard-decision based method (HDM), an implementation solution for linear decorrelating detector (LDD) in asynchronous DS/CDMA systems. By taking advantage of the preceding (already reconstructed) bit and the matched filter output for the following two bits, the coupling between temporally adjacent bits (TABs), which always exists for asynchronous systems, is greatly suppressed and the performance of the original HDM is substantially improved. This new scheme requires no signaling overhead yet offers nearly the same performance as those more complicated methods. Also, it can easily accommodate the change in the number of active users in the channel, as no symbol/bit grouping is involved. Finally, the influence of synchronisation errors is investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Greater attention has been focused on the use of CDMA for future cellular mobile communications. CA near-far resistant detector for asynchronous code-division multiple-access (CDMA) systems operating in additive white Gaussian noise (AWGN) channels is presented. The multiuser interference caused by K users transmitting simultaneously, each with a specific signature sequence, is completely removed at the receiver. The complexity of this detector grows only linearly with the number of users, as compared to the optimum multiuser detector which requires exponential complexity in the number of users. A modified algorithm based on time diversity is described. It performs detection on a bit-by-bit basis and overcomes the complexity of using a sequence detector. The performance of this detector is shown to be superior to that of the conventional receiver.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the effect of time offset errors on the partial parallel interference canceller (PIC) and compares the performance of it against that of the standard PIC. The BER performances of the standard and partial interference cancellers are simulated in a near far environment with varying time offset errors. These simulations indicate that whilst timing errors significantly affect the performance of both these schemes, they do not diminish the gains that are realised by the partial PIC over that of the standard PIC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Terahertz (THz) frequency radiation, 0.1 THz to 20 THz, is being investigated for biomedical imaging applications following the introduction of pulsed THz sources that produce picosecond pulses and function at room temperature. Owing to the broadband nature of the radiation, spectral and temporal information is available from radiation that has interacted with a sample; this information is exploited in the development of biomedical imaging tools and sensors. In this work, models to aid interpretation of broadband THz spectra were developed and evaluated. THz radiation lies on the boundary between regions best considered using a deterministic electromagnetic approach and those better analysed using a stochastic approach incorporating quantum mechanical effects, so two computational models to simulate the propagation of THz radiation in an absorbing medium were compared. The first was a thin film analysis and the second a stochastic Monte Carlo model. The Cole–Cole model was used to predict the variation with frequency of the physical properties of the sample and scattering was neglected. The two models were compared with measurements from a highly absorbing water-based phantom. The Monte Carlo model gave a prediction closer to experiment over 0.1 to 3 THz. Knowledge of the frequency-dependent physical properties, including the scattering characteristics, of the absorbing media is necessary. The thin film model is computationally simple to implement but is restricted by the geometry of the sample it can describe. The Monte Carlo framework, despite being initially more complex, provides greater flexibility to investigate more complicated sample geometries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modelling the interaction of terahertz(THz) radiation with biological tissueposes many interesting problems. THzradiation is neither obviously described byan electric field distribution or anensemble of photons and biological tissueis an inhomogeneous medium with anelectronic permittivity that is bothspatially and frequency dependent making ita complex system to model.A three-layer system of parallel-sidedslabs has been used as the system throughwhich the passage of THz radiation has beensimulated. Two modelling approaches havebeen developed a thin film matrix model anda Monte Carlo model. The source data foreach of these methods, taken at the sametime as the data recorded to experimentallyverify them, was a THz spectrum that hadpassed though air only.Experimental verification of these twomodels was carried out using athree-layered in vitro phantom. Simulatedtransmission spectrum data was compared toexperimental transmission spectrum datafirst to determine and then to compare theaccuracy of the two methods. Goodagreement was found, with typical resultshaving a correlation coefficient of 0.90for the thin film matrix model and 0.78 forthe Monte Carlo model over the full THzspectrum. Further work is underway toimprove the models above 1 THz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methods have recently been developed that make use of electromagnetic radiation at terahertz (THz) frequencies, the region of the spectrum between millimetre wavelengths and the infrared, for imaging purposes. Radiation at these wavelengths is non-ionizing and subject to far less Rayleigh scatter than visible or infrared wavelengths, making it suitable for medical applications. This paper introduces THz pulsed imaging and discusses its potential for in vivo medical applications in comparison with existing modalities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of terrestrial television multipath signals on the intermediate frequency (IF) vestigial sideband filter and the video detector are discussed. A new detector is proposed which, by processing the detected phase quadrature information, derives the correct phase for synchronous detection in the presence of multipath effects. This minimizes dispersion and produces a detected video signal with the linear addition of any ghosts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report preliminary results from studies of biological effects induced by non-thermal levels of non-ionizing electromagnetic radiation. Exponentially growing Saccharomyces cerevisiae yeast cells grown on dry media were exposed to electromagnetic fields in the 200–350 GHz frequency range at low power density to observe possible non-thermal effects on the microcolony growth. Exposure to the electromagnetic field was conducted over 2.5 h. The data from exposure and control experiments were grouped into either large-, medium- or small-sized microcolonies to assist in the accurate assessment of growth. The three groups showed significant differences in growth between exposed and control microcolonies. A statistically significant enhanced growth rate was observed at 341 GHz. Growth rate was assessed every 30 min via time-lapse photography. Possible interaction mechanisms are discussed, taking into account Frohlich's hypothesis.