1000 resultados para race detection
Resumo:
The increase of total choline in tumors has become an important biomarker in cancer diagnosis. Choline and choline metabolites can be measured in vivo and in vitro using multinuclear MRS. Recent in vivo(13)C MRS studies using labeled substrates enhanced via dynamic nuclear polarization demonstrated the tremendous potential of hyperpolarization for real-time metabolic studies. The present study demonstrates the feasibility of detecting hyperpolarized (15)N labeled choline in vivo in a rat head at 9.4 T. We furthermore report the in vitro (172 +/- 16 s) and in vivo (126 +/- 15 s) longitudinal relaxation times. We conclude that with appropriate infusion protocols it is feasible to detect hyperpolarized (15)N labeled choline in live animals.
Resumo:
In diabetes mellitus, it is expected to see a common, mainly sensitive, distal symmetrical polyneuropathy (DPN) involving a large proportion of diabetic patients according to known risk factors. Several other diabetic peripheral neuropathies are recognized, such as dysautonomia and multifocal neuropathies including lumbosacral radiculoplexus and oculomotor palsies. In this review, general aspects of DPN and other diabetic neuropathies are examined, and it is discussed why and how the general practionner has to perform a yearly examination. At the present time, some consensuses emerge to ask help from neurologist when faced to other forms of peripheral neuropathies than distal symmetrical DPN.
Resumo:
Two hundred and forty-five individuals of the common shrew (Sorex araneus, Insectivora, Mammalia) from 24 sampling localities situated in four different valleys of the western European Alps were genotyped for six microsatellite loci. Allelic variability ranged from 3 to 32 different alleles at a single locus and the average gene diversity over all loci was 0.69. An analysis for F and R statistics revealed weak genetic population subdivision (Fst = 0.032; Rst = 0.016). This suggests considerable gene flow and little phylogeographic structure within and between valleys. We tested whether a stepwise mutation model (SMM) better explained variation at the microsatellite loci than an infinite allele model (IAM). No trend in favor of either model was detected.
Resumo:
Purpose: To evaluate the diagnostic value of specific MR features for detection of suspected placental invasion according to observers' experience.Methods and Materials: Our study population included 25 pregnant women (mean age 35.16) investigated by prenatal MRI. In twelve out of them placental invasion was histopathologically proven, the 13 other women (52%) without placental invasion served as control group. Multiplanar T1- and T2-weighted sequences had been performed mostly without IV contrast injection (1.5 T). MR examinations of the two groups were rendered anonymous, mixed, then independently and retrospectively reviewed by two senior and two junior radiologists in view of 8 MR features indicating placentar invasion including the degree. Results were compared with surgical diagnosis (placenta normal/increta/accreta/percreta). Interobserver agrement between senior and junior readers were calculated. Stepwise logistic regression and receiver operating (ROC) curvers were performed.Results: Demographics between the two groups were not statistically different. Overall sensitivity and specificity for detecting placentar invasion was 90.9% and 75.0% for senior readers, and 81.8% and 61.8% for junior readers respectively. The most significant MR features indicating placentar invasion were T2 hypointense placental bands, followed by placenta praevia, focally interrupted myometrial border, posterior placental insertion, and heterogeneous placental signal. For each of the evaluated MR features the interobserver agreement kappa between the two senior readers was superior than that between the junior readers, ranging from bad (<0.4) to good (0.4-0.75).Conclusions: MRI can be a reliable and reproducible tool for detection of suspected placentar invasion, however very variable according to the observers' experience.
Resumo:
Chlamydia serology is indicated to investigate etiology of miscarriage, infertility, pelvic inflammatory disease, and ectopic pregnancy. Here, we assessed the reliability of a new automated-multiplex immunofluorescence assay (InoDiag test) to detect specific anti-C. trachomatis immunoglobulin G. Considering immunofluorescence assay (IF) as gold standard, InoDiag tests exhibited similar sensitivities (65.5%) but better specificities (95.1%-98%) than enzyme-linked immunosorbent assays (ELISAs). InoDiag tests demonstrated similar or lower cross-reactivity rates when compared to ELISA or IF.
Resumo:
Whereas the reduction of transfusion related viral transmission has been a priority during the last decade, bacterial infection transmitted by transfusion still remains associated to a high morbidity and mortality, and constitutes the most frequent infectious risk of transfusion. This problem especially concerns platelet concentrates because of their favorable bacterial growth conditions. This review gives an overview of platelet transfusion-related bacterial contamination as well as on the different strategies to reduce this problem by using either bacterial detection or inactivation methods.
Resumo:
BACKGROUND: Cytomegalovirus (CMV) infection is associated with significant morbidity and mortality in transplant recipients. Resistance against ganciclovir is increasingly observed. According to current guidelines, direct drug resistance testing is not always performed due to high costs and work effort, even when resistance is suspected. OBJECTIVES: To develop a more sensitive, easy applicable and cost-effective assay as proof of concept for direct drug resistance testing in CMV surveillance of post-transplant patients. STUDY DESIGN: Five consecutive plasma samples from a heart transplant patient with a primary CMV infection were analyzed by quantitative real-time polymerase chain reaction (rtPCR) as a surrogate marker for therapy failure, and by direct drug resistance detection assays such as Sanger sequencing and the novel primer extension (PEX) reaction matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) based method. RESULTS: This report demonstrates that PEX reaction followed by MALDI-TOF analysis detects the A594V mutation, encoding ganciclovir resistance, ten days earlier compared to Sanger sequencing and more than 30 days prior to an increase in viral load. CONCLUSION: The greatly increased sensitivity and rapid turnaround-time combined with easy handling and moderate costs indicate that this procedure could make a major contribution to improve transplantation outcomes.
Resumo:
The objective of this study was to evaluate the contribution of ultrasound scanning to the prenatal detection of trisomy 21 in a large unselected European population. Data from 19 congenital malformation registers in 11 European countries were included. The prenatal ultrasound screening programs in the countries ranged from no routine screening to three ultrasound investigations per patient. Routine serum screening was offered in four of the 11 countries and routine screening on the basis of maternal age amniocentesis in all. The results show that overall 53% of cases of trisomy 21 were detected prenatally with a range from 3% in Lithuania to 88% in Paris. Ninety-eight percent of women whose babies were diagnosed before 24 weeks gestation chose to terminate the pregnancy. Centres/countries that offer serum screening do not have a significantly higher detection rate of trisomy 21 when compared to those that offer maternal age amniocentesis and anomaly scanning only. Fifty percent of trisomy 21 cases were born to women aged 35 years or more. In conclusions, second trimester ultrasound plays an important role in the prenatal diagnosis of trisomy 21. Of those cases prenatally diagnosed, 64% of cases in women <35 years and 36% of those in women >or=35 years were detected because of an ultrasound finding. Ultrasound soft markers accounted for 84% of the scan diagnoses. There is evidence of increasing maternal age across Europe with 50% of cases of trisomy 21 born to women aged 35 years or more.
Resumo:
Source: Description: pKM-19 is a 1.0 kb EcoRI human genomic fragment inserted in pUC13, that detects a Scrfl (CC/NGG) RFLP (1, 2). We report here the primer sequences suitable for the detection of this RFLP by PCR...
Resumo:
Cette étude présente une analyse de l'évolution institutionnelle dans les Établissements français de l'Océanie (EFO, aujourd'hui la Polynésie française) durant la période 1880-1945. La particularité des EFO tient à ce qu'une partie de la population a reçu la citoyenneté française à l'annexion, l'autre partie ayant le statut de « sujets ». L'attention sera portée ici aux droits politiques effectifs plutôt qu'à ces catégorisations statutaires qui s'avèrent peu déterminantes. Ce sont plutôt des catégorisations racialistes qui sont sous-jacentes à l'attribution et la suppression des droits.
Resumo:
Avalanche photodiodes operated in the Geiger mode offer a high intrinsic gain as well as an excellent timing accuracy. These qualities make the sensor specially suitable for those applications where detectors with high sensitivity and low timing uncertainty are required. Moreover, they are compatible with standard CMOS technologies, allowing sensor and front-end electronics integration within the pixel cell. However, the sensor suffers from high levels of intrinsic noise, which may lead to erroneous results and limit the range of detectable signals. They also increase the amount of data that has to be stored. In this work, we present a pixel based on a Geiger-mode avalanche photodiode operated in the gated mode to reduce the probability to detect noise counts interfering with photon arrival events. The readout circuit is based on a two grounds scheme to enable low reverse bias overvoltages and consequently lessen the dark count rate. Experimental characterization of the fabricated pixel with the HV-AMS 0.35µm standard technology is also presented in this article.
Resumo:
Ammonia gas detection by pure and catalytically modified WO3 based gas sensor was analysed. The sensor response of pure WO3 to NH3 was not only rather low but also presented an abnormal behaviour, probably due to the unselective oxidation of ammonia to NOx. Copper and vanadium were introduced in different concentrations and the resulting material was annealed at different temperatures in order to improve the sensing properties for NH3 detection. The introduction of copper and vanadium as catalytic additives improved the response to NH3 and also eliminated the abnormal behaviour. Possible mechanisms of NH3 reaction over these materials are discussed. Sensor responses to other gases like NO2 or CO and the interference of humidity on ammonia detection were also analysed so as to choose the best sensing element.