984 resultados para plants per square meter
Resumo:
OBJECTIVE: To determine the prevalence of reagent serology for suspected acute toxoplasmosis in pregnant women and to describe clinical, laboratory and therapeutic profiles of mothers and their children. METHODS: A retrospective study was conducted with IgM-anti-Toxoplasma gondii-reagent pregnant women and their children who attended the public health system in the state of Paraná, Southern Brazil, from January 2001 to December 2003. Information were obtained from clinical, laboratory (ELISA IgM/IgG) and ultrasonographic data and from interviews with the mothers. To test the homogeneity of the IgM indices in relation to the treatment used, the Pearson's Chi-square test was applied. Comparisons were considered significant at a 5% level. RESULTS: Two hundred and ninety (1.0%) cases of suspected IgM-reagent infection were documented, with a prevalence of 10.7 IgM-reagent women per 1,000 births. Prenatal care started within the first 12 weeks for 214/290; 146/204 were asymptomatic. Frequent complaints included headaches, visual disturbance and myalgia. Ultrasonography revealed abnormalities in 13 of 204 pregnancies. Chemoprophylaxis was administered to 112/227; a single ELISA test supported most decisions to begin treatment. Pregnant women with IgM indices =2.000 tended to be treated more often. Among exposed children, 44/208 were serologically followed up and all were IgG-reagent, and three IgM-reagent cases showed clinical symptoms. CONCLUSIONS: The existence of pregnant women with laboratorially suspected acute toxoplasmosis who were not properly followed up, and of fetuses that were not adequately monitored, shows that basic aspects of the prenatal care are not being systematically observed. There is need of implementing a surveillance system of pregnant women and their children exposed to T. gondii.
Resumo:
Mestrado em Engenharia Química
Resumo:
The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.
Resumo:
Dissertação de Mestrado, Estudos Integrados dos Oceanos, 22 de Janeiro de 2016, Universidade dos Açores.
Resumo:
Este trabalho é realizado no domínio das obras de engenharia, área onde o desmonte de rocha com recurso a explosivos em obras rodoviárias é uma actividade específica e consistiu no acompanhamento e execução de três obras rodoviárias de média e grande dimensão. A necessidade de executar escavações, recorrendo a técnicas de desmonte cuidadoso de contorno, onde o plano de corte do talude final deve obedecer a requisitos de localização, alinhamento, inclinação, estabilidade e também estéticos, acrescendo a isto a necessidade de optimizar os meios envolvidos, obriga a que esta actividade seja encarada de uma forma sistematizada, visando o racional aproveitamento de recursos. A execução desta actividade requer conhecimentos no domínio das técnicas de desmonte de contorno, dos explosivos, do mecanismo de rotura de rochas, da operação de perfuração e da geomecânica dos maciços. A abordagem deste trabalho incide sobre a técnica denominada de pré‐corte e tem como objectivo encontrar uma equação característica que permita relacionar diferentes parâmetros envolvidos nesta actividade. Este objectivo é alcançado recorrendo à correlação entre equações relativas à pressão de detonação, à pressão no furo e ao espaçamento entre furos consecutivos, desenvolvidas por outros autores. Desta forma obteve‐se uma equação que relaciona parâmetros relativos ao maciço rochoso (resistência à tracção), ao explosivo (velocidade de detonação e densidade) e ao diagrama de fogo (concentração de carga – volume de explosivo e comprimento do furo – volume do furo). A comparação entre os valores destes parâmetros obtidos na produção e os obtidos com recurso à equação característica permite concluir que a sua aplicação para execução de futuras obras possibilita uma optimização dos meios envolvidos.
Resumo:
Filamentous fungi from genus Aspergillus were previously detected in wastewater treatment plants (WWTP) as being Aspergillus flavus (A. flavus), an important toxigenic fungus producing aflatoxins. This study aimed to determine occupational exposure adverse effects due to fungal contamination produced by A. flavus complex in two Portuguese WWTP using conventional and molecular methodologies. Air samples from two WWTP were collected at 1 m height through impaction method. Surface samples were collected by swabbing surfaces of the same indoor sites. After counting A. flavus and identification, detection of aflatoxin production was ensured through inoculation of seven inoculates in coconut-milk agar. Plates were examined under long-wave ultraviolet (UV; 365 nm) illumination to search for the presence of fluorescence in the growing colonies. To apply molecular methods, air samples were also collected using the impinger method. Samples were collected and collection liquid was subsequently used for DNA extraction. Molecular identification of A. flavus was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR detection system (Corbett). Among the Aspergillus genus, the species that were more abundant in air samples from both WWTP were Aspergillus versicolor (38%), Aspergillus candidus (29.1%), and Aspergillus sydowii (12.7%). However, the most commonly species found on surfaces were A. flavus (47.3%), Aspergillus fumigatus (34.4%), and Aspergillus sydowii (10.8%). Aspergillus flavus isolates that were inoculated in coconut agar medium were not identified as toxigenic strains and were not detected by RT-PCR in any of the analyzed samples from both plants. Data in this study indicate the need for monitoring fungal contamination in this setting. Although toxigenic strains were not detected from A. flavus complex, one cannot disregard the eventual presence and potential toxicity of aflatoxins.
Resumo:
A square-wave voltammetric (SWV) method using a hanging mercury drop electrode (HMDE) has been developed for determination of the herbicide molinate in a biodegradation process. The method is based on controlled adsorptive accumulation of molinate for 10 s at a potential of -0.8 V versus AgCl/Ag. An anodic peak, due to oxidation of the adsorbed pesticide, was observed in the cyclic voltammogram at ca. -0.320 V versus AgCl/Ag; a very small cathodic peak was also detected. The SWV calibration plot was established to be linear in the range 5.0x10-6 to 9.0x10-6 mol L-1; this corresponded to a detection limit of 3.5x10-8 mol L-1. This electroanalytical method was used to monitor the decrease of molinate concentration in river waters along a biodegradation process using a bacterial mixed culture. The results achieved with this voltammetric method were compared with those obtained by use of a chromatographic method (HPLC–UV) and no significant statistical differences were observed.
Resumo:
The reduction of luvastatin (FLV) at a hanging mercury-drop electrode (HMDE) was studied by square-wave adsorptive-stripping voltammetry (SWAdSV). FLV can be accumulated and reduced at the electrode, with a maximum peak current intensity at a potential of approximately 1.26V vs. AgCl=Ag, in an aqueous electrolyte solution of pH 5.25. The method shows linearity between peak current intensity and FLV concentration between 1.0 10 8 and 2.7 10 6 mol L 1. Limits of detection (LOD) and quantification (LOQ) were found to be 9.9 10 9 mol L 1 and 3.3 10 8 mol L 1, respectively. Furthermore, FLV oxidation at a glassy carbon electrode surface was used for its hydrodynamic monitoring by amperometric detection in a flow-injection system. The amperometric signal was linear with FLV concentration over the range 1.0 10 6 to 1.0 10 5 mol L 1, with an LOD of 2.4 10 7 mol L 1 and an LOQ of 8.0 10 7 mol L 1. A sample rate of 50 injections per hour was achieved. Both methods were validated and showed to be precise and accurate, being satisfactorily applied to the determination of FLV in a commercial pharmaceutical.
Resumo:
A square wave voltammetric (SWV) method and a flow injection analysis systemwi th electrochemical detection (FIA-EC) using a glassy carbon electrode were evaluated for the determination of codeine in pharmaceutical preparations. The interference of several compounds, such as acetaminophen,guaiacol, parabens, ephedrine, acetylsalicylic acid and caffeine, that usually appear associated with codeine pharmaceutical preparations was studied. It was verified that these electroanalytical methods could not be used with acetaminophen present in the formulations and that with guaiacol, parabens or ephedrine present the use of the FIA-EC system was impracticable. A detection limit of 5 µmol L- 1 and a linear calibration range from 40 to 140 µmol L- 1 was obtained with the SWV method. For the flow injection analysis procedure a linear calibration range was obtained from 7 to 50 µmol L- 1 with a detection limit of 3 µmol L- 1 and the FIA-EC systemallowed a sampling rate of 115 samples per hour. The results obtained by the two methods, SWV and FIA-EC, were compared with those obtained using reference methods and demonstrated good agreement, with relative deviations lower than 4%.
Resumo:
Fluvoxamine (FVX) can be reduced at a mercury- drop electrode, with a maximum peak current intensity being obtained at a potential of -0.7 V vs. Ag/ AgCl, in an aqueous electrolyte solution of pH 2. The compound was determined in a pharmaceutical product and in spiked human serum by square-wave adsorptivestripping voltammetry (SWAdSV) after accumulation at the electrode surface, under batch conditions. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine FVX in the pharmaceutical product by use of a flow-injection analysis (FIA) system with SWAdSV detection. The methods developed were validated and successfully applied to the quantification of FVX in a pharmaceutical product. Recoveries between 76 and 89% were obtained in serum analysis. The FIA– SWAdSV method enabled analysis of up to 120 samples per hour at reduced cost, implying the possibility of competing with the chromatographic methods usually used for this analysis.
Resumo:
Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with SWAdSV detection (FIA-SWAdSV) were developed for the determination of paroxetine (PRX). The methods were based on the reduction of PRX at a mercury drop electrode at −1.55V versus Ag/AgCl, in a borate buffer of pH 8.8, and the possibility of accumulating the compound at the electrode surface. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine PRX using FIASWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs. Both methods developed were validated and successfully applied to the quantification of PRX in pharmaceutical products.
Resumo:
Two analytical methods for the quality control of dihydrocodeine in commercial pharmaceutical formulations have been developed and compared with reference methods: a square wave voltammetric (SWV) method and a flow injection analysis system with electrochemical detection (FIA-EC). The electrochemical methods proposed were successfully applied to the determination of dihydrocodeine in pharmaceutical tablets and in oral solutions. These methods do not require any pretreatment of the samples, the formulation only being dissolved in a suitable electrolyte. Validation of the methods showed it to be precise, accurate and linear over the concentration range of analysis. The automatic procedure based on a flow injection analysis manifold allows a sampling rate of 115 determinations per hour.
Resumo:
OBJECTIVE: To estimate the prevalences of tuberculosis and latent tuberculosis in inmates. METHODS: Observational study was carried out with inmates of a prison and a jail in the State of São Paulo, Southeastern Brazil, between March and December of 2008. Questionnaires were used to collect sociodemographic and epidemiological data. Tuberculin skin testing was administered (PPD-RT23-2TU/0.1 mL), and the following laboratory tests were also performed: sputum smear examination, sputum culture, identification of strains isolated and drug susceptibility testing. The variables were compared using Pearson's chi-square (Χ2) association test, Fisher's exact test and the proportion test. RESULTS: Of the 2,435 inmates interviewed, 2,237 (91.9%) agreed to submit to tuberculin skin testing and of these, 73.0% had positive reactions. The prevalence of tuberculosis was 830.6 per 100,000 inmates. The coefficients of prevalence were 1,029.5/100,000 for inmates of the prison and 525.7/100,000 for inmates of the jail. The sociodemographic characteristics of the inmates in the two groups studied were similar; most of the inmates were young and single with little schooling. The epidemiological characteristics differed between the prison units, with the number of cases of previous tuberculosis and of previous contact with the disease greater in the prison and coughing, expectoration and smoking more common in the jail. Among the 20 Mycobacterium tuberculosis strains identified, 95.0% were sensitive to anti-tuberculosis drugs, and 5.0% were resistant to streptomycin. CONCLUSIONS: The prevalences of tuberculosis and latent tuberculosis were higher in the incarcerated population than in the general population, and they were also higher in the prison than in the jail.
Resumo:
The consumption of natural products has become a public health problem, since these medicinal teas are prepared using natural plants without an effective hygienic and sanitary control. The aim of this study was to assess the effects of gamma radiation, on the microbial burden of two medicinal plants: Melissa officinalis and Lippia citriodora. Dried samples of the two plants were irradiated at a Co-60 experimental equipment. The applied gamma radiation doses were 1, 3, and 5 kGy at a dose rate of 1.34 kGy/h. Non-irradiated samples followed all the experiments. Bacterial and fungal counts were assessed before and after irradiation by membrane filtration method. Challenging tests with Escherichia coli were performed in order to evaluate the disinfection efficiency of gamma radiation treatment. Characterization of M. officinalis and L. citriadora microbiota indicated an average bioburden value of 102CFU/g. The inactivation studies of the bacterial mesophilic population of both dried plants pointed out to a one log reduction of microbial load after irradiation at 5 kGy. Regarding the fungal population, the initial load of 30 CFU/g was only reduced by 0.5 log by an irradiation dose of 5 kGy. The dynamics with radiation doses of plants microbial population’s phenotypes indicated the prevalence of gram-positive rods for M. officinalis before and after irradiation, and the increase of the frequency of gram-negative rods with irradiation for L. citriadora. Among fungal population of both plants, Mucor, Neoscytalidium, Aspergillus and Alternaria were the most isolated genera. The results obtained in the challenging tests with E. coli on plants pointed out to an inactivation efficiency of 99.5% and 99.9% to a dose of 2 kGy, for M.officinalis and L. citriadora, respectively. The gamma radiation treatment can be a significant tool for the microbial control in medicinal plants.
Resumo:
This paper presents a single precision floating point arithmetic unit with support for multiplication, addition, fused multiply-add, reciprocal, square-root and inverse squareroot with high-performance and low resource usage. The design uses a piecewise 2nd order polynomial approximation to implement reciprocal, square-root and inverse square-root. The unit can be configured with any number of operations and is capable to calculate any function with a throughput of one operation per cycle. The floatingpoint multiplier of the unit is also used to implement the polynomial approximation and the fused multiply-add operation. We have compared our implementation with other state-of-the-art proposals, including the Xilinx Core-Gen operators, and conclude that the approach has a high relative performance/area efficiency. © 2014 Technical University of Munich (TUM).