975 resultados para photo-hemolysis
Resumo:
For modern consumer cameras often approximate calibration data is available, making applications such as 3D reconstruction or photo registration easier as compared to the pure uncalibrated setting. In this paper we address the setting with calibrateduncalibrated image pairs: for one image intrinsic parameters are assumed to be known, whereas the second view has unknown distortion and calibration parameters. This situation arises e.g. when one would like to register archive imagery to recently taken photos. A commonly adopted strategy for determining epipolar geometry is based on feature matching and minimal solvers inside a RANSAC framework. However, only very few existing solutions apply to the calibrated-uncalibrated setting. We propose a simple and numerically stable two-step scheme to first estimate radial distortion parameters and subsequently the focal length using novel solvers. We demonstrate the performance on synthetic and real datasets.
Resumo:
The evolution of computer animation represents one of the most relevant andrevolutionary aspects in the rise of contemporary digital visual culture (Darlew,2000), in particular, phenomena such as cinema “spectacular “ (Ibidem) and videogames. This article analyzes the characteristics of this “culture of simulation” (Turkle, 1995:20) relating the multidisciplinary and spectrum of technical and stylistic choices to the dimension of virtual characters acting. The result of these hybrid mixtures and computerized human motion capture techniques - called virtual cinema, universal capture, motion capture, etc. - cosists mainly on the sophistication of “rotoscoping”, as a new interpretation and appropriation of the captured image. This human motion capture technology, used largely by cinema and digital games, is one of the reasons why the authenticity of the animation is sometimes questioned. It is in the fi eld of 3D computer animation visual that this change is more signifi cant, appearing regularly innovative techniques of image manipulation and “hyper-cinema” (Lamarre, 2006: 31) character’s control with deeper sense of emotions. This shift in the culture that Manovich (2006: 27) calls “photo-GRAPHICS” - and Mulvey (2007) argue that creates a new form of possessive relationship with the viewer, in that it can analyze in detail the image, it can acquire it and modify it - is one of the most important aspects in the rise of Cubbit’s (2007) “cinema of attraction”. This article delves intrinsically into the analyze of virtual character animation — particularly in the fi eld of 3D computer animation and human digital acting.
Resumo:
Introdução – O formaldeído está enquadrado entre as 25 substâncias químicas mais abundantemente produzidas no mundo devendo-se essencialmente à sua elevada reactividade, ausência de cor, à sua pureza no formato comercial e, ainda, ao seu baixo custo. A IARC, desde 2006, classifica o formaldeído no Grupo 1 (agente carcinogénico) com base na evidência de que a exposição a formaldeído é susceptível de causar cancro nasofaríngeo em humanos. Desenvolveu-se um estudo de natureza exploratóra com o objectivo essencial de obter informação sobre a realidade da exposição profissional a formaldeído em Portugal. Igualmente, pretendeu-se conhecer a adequabilidade de uma nova metodologia de monitorização ambiental ao estudo da exposição ocupacional a formaldeído. Metodologia – Realizaram-se várias medições das concentrações de formaldeído em 7 unidades industriais e num laboratório hospitalar de anatomia patológica. As avaliações ambientais foram concretizadas com recurso a um equipamento de leitura directa que realiza a medição por Photo Ionization Detection (PID), com uma lâmpada de 11,7 eV. Resultados – No laboratório de anatomia patológica estudado foram registados valores de concentração superiores ao valor-limite de referência (0,3 ppm). Igualmente, em 2 das 7 unidades industriais estudadas foram registados valores de concentração máxima superiores a 0,3 ppm. Conclusões – Em consonância com outros estudos, o laboratório de anatomia patológica apresentou-se como o contexto ocupacional onde a exposição a formaldeído apresenta as concentrações mais elevadas. A metodologia adoptada para monitorização ambiental parece adequar-se aos objectivos da presente investigação e relacionada com o modo de actuação do agente químico em estudo.
Resumo:
Formaldehyde was the first air pollutant, which already in the 1970s emerged as a specifically non-industrial indoor air quality problem. Yet formaldehyde remained an indoor air quality issue and the formaldehyde level in residential indoor air is among the highest of any indoor air contaminant. Formaldehyde concentrations in 4 different indoor settings (schools, office buildings, new dwellings and occupied dwellings) in Portugal were measured using Photo Ionization Detection (PID) equipment (11,7 eV lamps). All the settings presented results higher than the reference value proposed by Portuguese legislation. Furthermore, occupied dwellings showed 3 units with results above the reference. We could conclude that formaldehyde presence is a reality in monitored indoor settings. Concentration levels are higher than the Portuguese reference value for indoor settings and these can indicate health problems for occupants.
Resumo:
OBJECTIVE: The assessment of an easy to prepare and low cost control material for Hematology, available for manual and automated methods. MATERIAL AND METHOD: Aliquots of stabilized whole blood were prepared by partial fixation with aldehydes; the stability at different temperatures (4. 20 and 37 °C) during periods of up to 8-9 weeks and aliquot variability with both methods were controlled. RESULTS: Aliquot variability with automated methods at day 1, expressed as CV% (coefficient of variation) was: white blood cells (WBC) 2.7, red blood cells (RBC) 0.7, hemoglobin (Hb) 0.6, hematocrit (Hct) 0.7, mean cell volume (MCV) 0.3, mean cell hemoglobin (MCH) 0.6, mean cell hemoglobin concentration (MCHC) 0.7, and platelets (PLT) 4.6. The CV (coefficient of variation) percentages obtained with manual methods in one of the batches were: WBC 23, Hct 2.8, Hb 4.5, MCHC 5.9, PLT 41. Samples stored at 4ºC and 20ºC showed good stability, only a very low initial hemolysis being observed, whereas those stored at 37ºC deteriobed a rapidly (metahemoglobin formation, aggregation of WBC and platelets, as well as alteration of erythrocyte indexes). CONCLUSIONS: It was confirmed that, as long as there is no exposure to high temperatures during distribution, this material is stable, allowing assessment, both esternal and internal, for control purposes, with acceptable reproductivity, both for manual and auttomatic methods.
Resumo:
In this paper, we present results on the use of multilayered a-SiC:H heterostructures as a device for wavelength-division demultiplexing of optical signals. These devices are useful in optical communications applications that use the wavelength division multiplexing technique to encode multiple signals into the same transmission medium. The device is composed of two stacked p-i-n photodiodes, both optimized for the selective collection of photo generated carriers. Band gap engineering was used to adjust the photogeneration and recombination rate profiles of the intrinsic absorber regions of each photodiode to short and long wavelength absorption in the visible spectrum. The photocurrent signal using different input optical channels was analyzed at reverse and forward bias and under steady state illumination. A demux algorithm based on the voltage controlled sensitivity of the device was proposed and tested. An electrical model of the WDM device is presented and supported by the solution of the respective circuit equations.
Resumo:
Characteristics of tunable wavelength pi'n/pin filters based on a-SiC:H multilayered stacked cells are studied both experimental and theoretically. Results show that the device combines the demultiplexing operation with the simultaneous photodetection and self amplification of the signal. An algorithm to decode the multiplex signal is established. A capacitive active band-pass filter model is presented and supported by an electrical simulation of the state variable filter circuit. Experimental and simulated results show that the device acts as a state variable filter. It combines the properties of active high-pass and low-pass filter sections into a capacitive active band-pass filter using a changing photo capacitance to control the power delivered to the load.
Resumo:
A exposição a formaldeído é reconhecidamente um dos mais importantes factores de risco presente nos laboratórios hospitalares de anatomia patológica. Neste contexto ocupacional, o formaldeído é utilizado em solução, designada comummente por formol. Trata-se de uma solução comercial de formaldeído, normalmente diluída a 10%, sendo pouco onerosa e, por esse motivo, a eleita para os trabalhos de rotina em anatomia patológica. A solução é utilizada como fixador e conservante do material biológico, pelo que as peças anatómicas a serem processadas são previamente impregnadas. No que concerne aos efeitos cancerígenos, a primeira avaliação efectuada pela International Agency for Research on Cancer data de 1981, actualizada em 1982, 1987, 1995 e 2004, considerando-o como um agente cancerígeno do grupo 2A (provavelmente carcinogénico). No entanto, a mais recente avaliação, em 2006, considera o formaldeído no Grupo 1 (agente carcinogénico) com base na evidência de que a exposição a este agente é susceptível de causar cancro nasofaríngeo em humanos. Constituiu objectivo principal do estudo desenvolvido caracterizar a exposição profissional a formaldeído em laboratórios hospitalares de anatomia patológica. O estudo incidiu sobre 10 laboratórios hospitalares de anatomia patológica situados em Portugal Continental. Foi avaliada a exposição dos trabalhadores considerando três grupos profissionais (Técnicos de Anatomia Patológica, Médicos Anatomo-Patologistas e Auxiliares) por comparação com dois referenciais de exposição (VLE-CM e VLE-MP) e, ainda, considerados os valores de concentração máxima em 83 actividades desenvolvidas nos laboratórios pertencentes à amostra. Foram aplicados simultaneamente dois métodos distintos de avaliação ambiental: um dos métodos (Método 1) fez uso de um equipamento de leitura directa com o princípio de medição por Photo Ionization Detection, com uma lâmpada de 11,7 eV, realizando-se, simultaneamente, o registo da actividade de trabalho − foram assim obtidos dados para o referencial de exposição da concentração máxima (CM); o outro método (Método 2) traduziu-se na aplicação do método NIOSH 2541, implicando o uso de bombas de amostragem eléctricas de baixo caudal e posterior processamento analítico das amostras por cromatografia gasosa − este método, por sua vez, facultou dados para o referencial de exposição da concentração média ponderada (CMP). A aplicação simultânea dos dois métodos de avaliação ambiental resultou na obtenção de resultados distintos, mas não contraditórios, no que concerne à avaliação da exposição profissional a formaldeído. Para as actividades estudadas (n=83) verificou-se que cerca de 93% dos valores são superiores ao valor limite de exposição definido para a concentração máxima (VLE-CM=0,3 ppm). O “exame macroscópico” foi a actividade mais estudada e onde se verificou a maior prevalência de resultados superiores ao valor limite (92,8%). O valor médio mais elevado da concentração máxima (2,04 ppm) verificou-se no grupo de exposição dos Técnicos de Anatomia Oatológica. No entanto, a maior amplitude de resultados observou-se no grupo dos Médicos Anatomo-Patologistas (0,21 ppm a 5,02 ppm). No que respeita ao referencial da Concentração Média Ponderada, todos os valores obtidos nos 10 laboratórios estudados para os três grupos de exposição foram inferiores ao valor limite de exposição definido pela Occupational Safety and Health Administration (TLV-TWA=0,75 ppm). Dado não se perspectivar a curto prazo a eliminação do formaldeído, devido ao grande número de actividades que envolvem ainda a utilização da sua solução comercial (formol), pode concluir-se que a exposição a este agente neste contexto ocupacional específico é preocupante, carecendo de uma intervenção rápida com o objectivo de minimizar a exposição e prevenir os potenciais efeitos para a saúde dos trabalhadores expostos.
Resumo:
Amorphous Si/SiC photodiodes working as photo-sensing or wavelength sensitive devices have been widely studied. In this paper single and stacked a-SiC:H p-i-n devices, in different geometries and configurations, are reviewed. Several readout techniques, depending on the desired applications (image sensor, color sensor, wavelength division multiplexer/demultiplexer device) are proposed. Physical models are presented and supported by electrical and numerical simulations of the output characteristics of the sensors.
Resumo:
The application of a-SiC:H/a-Si:H pinpin photodiodes for optoelectronic applications as a WDM demultiplexer device has been demonstrated useful in optical communications that use the WDM technique to encode multiple signals in the visible light range. This is required in short range optical communication applications, where for costs reasons the link is provided by Plastic Optical Fibers. Characterization of these devices has shown the presence of large photocapacitive effects. By superimposing background illumination to the pulsed channel the device behaves as a filter, producing signal attenuation, or as an amplifier, producing signal gain, depending on the channel/background wavelength combination. We present here results, obtained by numerical simulations, about the internal electric configuration of a-SiC:H/a-Si:H pinpin photodiode. These results address the explanation of the device functioning in the frequency domain to a wavelength tunable photo-capacitance due to the accumulation of space charge localized at the bottom diode that, according to the Shockley-Read-Hall model, it is mainly due to defect trapping. Experimental result about measurement of the photodiode capacitance under different conditions of illumination and applied bias will be also presented. The combination of these analyses permits the description of a wavelength controlled photo-capacitance that combined with the series and parallel resistance of the diodes may result in the explicit definition of cut off frequencies for frequency capacitive filters activated by the light background or an oscillatory resonance of photogenerated carriers between the two diodes. (C) 2013 Elsevier B.V. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
25th Conference of the European Cetacean Society. Long-terms datasets on marine mammals: learning from the past to manage the future, Cadiz, Spain, 21-23 March 2011.
Resumo:
26th Annual Conference of the European Cetacean Society, Galway, Ireland 26-28 March 2012.
Resumo:
27th Annual Conference of the European Cetacean Society. Setúbal, Portugal, 8-10 April 2013.
Resumo:
27th Annual Conference of the European Cetacean Society. Setúbal, Portugal, 8-10 April 2013.