966 resultados para pharmaceutical care


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim and objectives To examine how nurses collect and use cues from respiratory assessment to inform their decisions as they wean patients from ventilatory support. Background Prompt and accurate identification of the patient's ability to sustain reduction of ventilatory support has the potential to increase the likelihood of successful weaning. Nurses' information processing during the weaning from mechanical ventilation has not been well-described. Design A descriptive ethnographic study exploring critical care nurses' decision-making processes when weaning mechanically ventilated patients from ventilatory support in the real setting. Methods Novice and expert Scottish and Greek nurses from two tertiary intensive care units were observed in real practice of weaning mechanical ventilation and were invited to participate in reflective interviews near the end of their shift. Data were analysed thematically using concept maps based on information processing theory. Ethics approval and informed consent were obtained. Results Scottish and Greek critical care nurses acquired patient-centred objective physiological and subjective information from respiratory assessment and previous knowledge of the patient, which they clustered around seven concepts descriptive of the patient's ability to wean. Less experienced nurses required more encounters of cues to attain the concepts with certainty. Subjective criteria were intuitively derived from previous knowledge of patients' responses to changes of ventilatory support. All nurses used focusing decision-making strategies to select and group cues in order to categorise information with certainty and reduce the mental strain of the decision task. Conclusions Nurses used patient-centred information to make a judgment about the patients' ability to wean. Decision-making strategies that involve categorisation of patient-centred information can be taught in bespoke educational programmes for mechanical ventilation and weaning. Relevance to clinical practice Advanced clinical reasoning skills and accurate detection of cues in respiratory assessment by critical care nurses will ensure optimum patient management in weaning mechanical ventilation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cumbers, B., Urquhart, C. & Durbin, J. (2006). Evaluation of the KA24 (Knowledge Access 24) service for health and social care staff in London and the South-East of England. Part 1: Quantitative. Health Information and Libraries Journal, 23(2), 133-139 Sponsorship: KA24 - NHS Trusts, London

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cooper, J. & Urquhart, C. (2005). Developing an effective electronic social care record for care in the home. In J. Bryant (Ed.), Current Perspectives in Healthcare Computing conference, Harrogate 21-23 March 2005 (CD-ROM). Swindon: BCS HIC Sponsorship: AHRC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cooper, J. & Urquhart, C. (2004). Confidentiality issues in information systems in social care. In K. Grant, D.A. Edgar & M. Jordan (Eds.), Reflections on the past, making sense of today and predicting the future of information systems, 9th annual UKAIS (UK Academy of Information Systems) conference proceedings, Annual conference, 5-7 May 2004, Glasgow Caledonian University (CD-ROM). Glasgow: Glasgow Caledonian University for UKAIS Sponsorship: AHRC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cooper, J. & Urquhart, C. (2005). The information needs and information-seeking behaviours of home-care workers and clients receiving home care. Health Information and Libraries Journal, 22(2), 107-116. Sponsorship: AHRC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urquhart,C., Spink, S., Thomas, R. & Weightman, A. (2007). Developing a toolkit for assessing the impact of health library services on patient care. Report to LKDN (Libraries and Knowledge Development Network). Aberystwyth: Department of Information Studies, Aberystwyth University. Sponsorship: Libraries and Knowledge Development Network/ NHS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Depression is a common but frequently undiagnosed feature in individuals with HIV infection. To find a strategy to detect depression in a non-specialized clinical setting, the overall performance of the Hospital Anxiety and Depression Scale (HADS) and the depression identification questions proposed by the European AIDS Clinical Society (EACS) guidelines were assessed in a descriptive cross-sectional study of 113 patients with HIV infection. The clinician asked the two screening questions that were proposed under the EACS guidelines and requested patients to complete the HADS. A psychiatrist or psychologist administered semi-structured clinical interviews to yield psychiatric diagnoses of depression (gold standard). A receiver operating characteristic (ROC) analysis for the HADS-Depression (HADS-D) subscale indicated that the best sensitivity and specificity were obtained between the cut-off points of 5 and 8, and the ROC curve for the HADS-Total (HADS-T) indicated that the best cut-off points were between 12 and 14. There were no statistically significant differences in the correlations of the EACS (considering positive responses to one [A] or both questions [B]), the HADS-D ≥ 8 or the HADS-T ≥ 12 with the gold standard. The study concludes that both approaches (the two EACS questions and the HADS-D subscale) are appropriate depression-screening methods in HIV population. We believe that using the EACS-B and the HADS-D subscale in a two-step approach allows for rapid, assumable and accurate clinical diagnosis in non-psychiatric hospital settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cooper, J. & Urquhart, C. (2008). Homecare and the informal information grapevine: implications for the electronic record in social care. Health Informatics Journal, 14(1), 59-69. Sponsorship: AHRC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concentrations of 12 pharmaceutical compounds (atenolol, erythromycin, cyclophosphamide, paracetamol, bezafibrate, carbamazepine, ciprofloxacin, caffeine, clarithromycin, lidocaine, sulfamethoxazole and Nacetylsulfamethoxazol (NACS)) were investigated in the influents and effluents of two hospital wastewater treatment plants (HWWTPs) in Saudi Arabia. The majority of the target analytes were detected in the influent samples apart from bezafibrate, cyclophosphamide, and erythromycin. Caffeine and paracetamol were detected in the influent at particularly high concentrations up to 75 and 12 ug/L, respectively. High removal efficiencies of the pharmaceutical compounds were observed in both HWWTPs, with greater than 90 % removal on average. Paracetamol, sulfamethoxazole, NACS, ciprofloxacin, and caffeine were eliminated by between >95 and >99 % on average. Atenolol, carbamazepine, and clarithromycin were eliminated by >86 % on average. Of particular interest were the high removal efficiencies of carbamazepine and antibiotics that were achieved by the HWWTPs; these compounds have been reported to be relatively recalcitrant to biological treatment and are generally only partially removed. Elevated temperatures and high levels of sunlight were considered to be the main factors that enhanced the removal of these compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Ciências Farmacêuticas

Relevância:

20.00% 20.00%

Publicador:

Resumo:

University of Pretoria / MA Dissertation / Department of Practical Theology / Advised by Prof M J S Masango

Relevância:

20.00% 20.00%

Publicador:

Resumo:

M.A. Thesis / University of Pretoria / Department of Practical Theology / Advised by Prof M Masango

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In a 1994 Ninth Circuit decision on the remand of Daubert v. Merrell Dow Pharmaceuticals, Inc., Judge Alex Kosinski wrote that science done for the purpose of litigation should be subject to more stringent standards of admissibility than other science. OBJECTIVES: We analyze this proposition by considering litigation-generated science as a subset of science involving conflict of interest. DISCUSSION: Judge Kosinski's formulation suggests there may be reasons to treat science involving conflict of interest differently but raises questions about whether litigation-generated science should be singled out. In particular we discuss the similar problems raised by strategically motivated science done in anticipation of possible future litigation or otherwise designed to benefit the sponsor and ask what special treatment, if any, should be given to science undertaken to support existing or potential future litigation. CONCLUSION: The problems with litigation-generated science are not special. On the contrary, they are very general and apply to much or most science that is relevant and reliable in the courtroom setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adequate hand-washing has been shown to be a critical activity in preventing the transmission of infections such as MRSA in health-care environments. Hand-washing guidelines published by various health-care related institutions recommend a technique incorporating six hand-washing poses that ensure all areas of the hands are thoroughly cleaned. In this paper, an embedded wireless vision system (VAMP) capable of accurately monitoring hand-washing quality is presented. The VAMP system hardware consists of a low resolution CMOS image sensor and FPGA processor which are integrated with a microcontroller and ZigBee standard wireless transceiver to create a wireless sensor network (WSN) based vision system that can be retargeted at a variety of health care applications. The device captures and processes images locally in real-time, determines if hand-washing procedures have been correctly undertaken and then passes the resulting high-level data over a low-bandwidth wireless link. The paper outlines the hardware and software mechanisms of the VAMP system and illustrates that it offers an easy to integrate sensor solution to adequately monitor and improve hand hygiene quality. Future work to develop a miniaturized, low cost system capable of being integrated into everyday products is also discussed.