954 resultados para peri-implantitis
Resumo:
Between 2000 and 2004, 170 sand flies were captured in urban or peri-urban areas of the Rio Claro city, SP, Brazil. Nyssomyia neivai, the main LTA vector species in São Paulo territory, corresponded to 124 specimens (72,94%) of the total number of captured insects. Incidence of American Cutaneous (LTA) and Visceral leishmaniasis (LVA) is increasing in human and dogs in São Paulo State. Rio Claro city is located in the center-east region of the State. During 2001 and 2003, two cases of alochtonus canine LVA and an autochthonous case of canine LTA were locally diagnosed. Results indicate the risk of LVA establishment in this region. Possible role of alternative vectors in leishmaniasis transmission is discussed.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
JUSTIFICATIVA E OBJETIVOS: Os efeitos e o potencial sinergismo entre a clonidina, um agonista alfa2-adrenérgico, e a ropivacaína ainda não foram estudados em pacientes sob anestesia peridural. O objetivo da pesquisa foi estudar os efeitos da associação da clonidina com a ropivacaína, nas características do bloqueio peridural. MÉTODO: Participaram do estudo duplamente encoberto, 60 pacientes distribuídos em dois grupos de 30 pacientes. No grupo G controle, foi usada apenas a ropivacaína a 0,75% (150 mg) na anestesia peridural; no grupo G clonidina, foram utilizadas clonidina (300 µg) e ropivacaína a 0,75% (150 mg) na anestesia peridural. Foram analisados os seguintes atributos: bloqueio analgésico completo (tempo de latência), instalação do bloqueio motor, duração dos bloqueios analgésico e motor, nível máximo do bloqueio analgésico, nível de consciência, necessidade de analgesia e sedação complementar no per-operatório, ocorrência de hipotensão arterial no per e pós-operatórios, intensidade da dor pós-operatória, duração da analgesia e efeitos colaterais. RESULTADOS: A clonidina (300 µg), por via peridural, não influenciou a latência (p > 0,05); porém prolongou a duração dos bloqueios analgésico e motor (p < 0,0001) e a analgesia pós-operatória (p < 0,001). A proporção de hipotensão arterial foi pequena e semelhante entre os grupos, mas houve maior incidência de bradicardia (p < 0,02) e sedação (p < 0,001) no grupo que utilizou a clonidina. A incidência de tremores foi menor no grupo da clonidina (p < 0,001). CONCLUSÕES: Nas condições deste estudo e nas doses empregadas, pode-se concluir que há sinergismo evidente entre a clonidina e a ropivacaína na anestesia peridural. A clonidina aumenta a duração dos bloqueios analgésico e motor da anestesia peridural com a ropivacaína e prolonga a analgesia pós-operatória. A clonidina apresenta como vantagens adicionais, o aumento da sedação dos pacientes e a redução na incidência de tremores, mas aumenta a ocorrência de bradicardia.
Resumo:
JUSTIFICATIVA E OBJETIVOS: A utilização das drogas agonistas dos alfa2-adrenoceptores para controlar a pressão arterial e freqüência cardíaca, propiciar menores respostas hemodinâmicas à intubação e extubação traqueal e poupar anestésicos já está difundida na literatura desde a introdução da clonidina. O desenvolvimento de agentes providos de maior seletividade alfa2-adrenoceptora que, por isso, determinam menos efeitos adversos, como a dexmedetomidina, recentemente liberada para utilização clínica, possibilitou que ocorressem maior sedação e analgesia com o seu uso. Despertou-se, então, o interesse em sua utilização como substitutos dos opióides, conhecidos por determinarem potente analgesia e sedação. O objetivo deste trabalho foi comparar a analgesia promovida pela dexmedetomidina e pelo sufentanil, utilizados em infusões contínuas durante anestesias de procedimentos otorrinolaringológicos e de cabeça e pescoço. MÉTODO: Os 60 pacientes estudados foram divididos em dois grupos de 30: G1, recebendo sufentanil e G2, dexmedeto- midina, na indução e manutenção anestésicas. Para a manutenção da anestesia utilizaram-se, também, o óxido nitroso e o propofol, em infusão contínua alvo-controlada. Foram avaliados os parâmetros hemodinâmicos (pressões arteriais sistólica e diastólica e freqüência cardíaca), tempos de despertar e de extubação após interrupção do propofol, locais onde foram extubados os pacientes, sala de operação (SO) ou sala de recuperação pós-anestésica (SRPA), tempo de permanência na SRPA, índice de Aldrete e Kroulik e as complicações apresentadas na SO e SRPA. RESULTADOS: G1 apresentou menores valores de pressões arteriais sistólica, diastólica e freqüência cardíaca, tempos de despertar e extubação maiores, maior número de extubações na SRPA, maior tempo de permanência na SRPA, valores mais baixos para Aldrete e Kroulik na alta da SRPA e mais complicações per e pós-operatórias. CONCLUSÕES: A utilização de dexmedetomidina como analgésico per-operatório apresentou melhores resultados que a de sufentanil, nos procedimentos selecionados neste trabalho, com relação à estabilidade hemodinâmica e às condições de despertar e de recuperação anestésica.
Resumo:
Aim: To evaluate the effect of implant length (6 mm vs. 11 mm) on osseointegration (bone-toimplant contact) of implants installed into sockets immediately after tooth extraction.Material and methods: In six Labrador dogs, the pulp tissue of the mesial roots of P-3(3) was removed and the root canals were filled. Flaps were elevated bilaterally, the premolars hemisectioned and the distal roots removed. Recipient sites were prepared in the distal alveolus and a 6 mm or an 11 mm long implant was installed at the test and control sites, respectively. Non-submerged healing was allowed. After 4 months of healing, block sections of the implant sites were obtained for histological processing and peri-implant tissue assessment.Results: No statistically significant differences were found between test and control sites both for hard and soft tissue parameters. The bone-to-implant contact evaluated at the apical region of the implants was similar as well. Although not statistically significant, the location of the top of the bony crest at the buccal aspect was more apical in relation to the implant shoulder at the test compared with the control sites (2.0 +/- 1.4 and 1.2 +/- 1.1 mm, respectively).Conclusions: Shorter implants (6 mm) present with equal osseointegration than do longer implants (11 mm).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Aim: To evaluate the effect of mismatching abutments on implants with a wider platform on the peri-implant hard tissue remodeling and the soft tissue dimensions.Material and methods: Mandibular premolars and first molars of six Labrador dogs were extracted bilaterally. After 3 months of healing, one tapered implant was installed on each side of the mandibular molar region with the implant shoulder placed at the level of the buccal alveolar bony crest. on the right side of the mandible, an abutment of reduced diameter in relation to the platform of the implant was used, creating a mismatch of 0.85 mm (test), whereas an abutment of the same diameter of the implant platform was affixed in the left side of the mandible (control). The flaps were sutured to allow a non-submerged healing. After 4 months, the animals were sacrificed and ground sections were obtained for histometric assessment.Results: All implants were completely osseo-integrated. Bone levels were superior at the test than at the control sites. However, statistically significant differences were found only at the buccal and proximal aspects. The soft tissue vertical dimension was higher at the control compared with the test sites. However, statistically significant differences were demonstrated only at the buccal aspects.Conclusions: A mismatch of 0.85 mm between the implant and the abutment yielded more coronal levels of bone-to-implant contact and a reduced height of the peri-implant soft tissue (biologic width), especially at the buccal aspect, if the implant shoulder was placed flush with the level of the buccal alveolar bony crest.
Resumo:
Aim: To validate the platform switching concept at oral implants with respect to the preservation of the alveolar crestal bone levels in an animal model. Material & methods: Five minipigs received three implants each with a 0.25mm implant/ abutment mismatch and were placed flush (T(0)), 1 mm below (T(1)) and 1 mm above (T(+1)) the alveolar bony crest, and as a control, one conventionally restored implant placed at the bone level. The implants were randomly inserted flapless into the mandible. Four months after implant insertion, the animals were sacrificed, and undecalcified block sections were obtained and used for histological analyses. Results: The mean values for peri- implant bone resorption were 1.09 +/- 0.59mm (Control), 0.51 (+/- 0.27 mm, T(0)), 0.50 (+/- 0.46 mm, T(1)) and 1.30 (+/- 0.21 mm, T (+1)), respectively. Statistically significant differences (P< 0.05) were found among the test (T(0), T(-1)) and the control sites. Control implants presented an average biologic width length of 3.20mm (+/- 0.33), with a connective tissue adaptation compartment of 1.29mm (+/- 0.53) and an epithelial attachment of 1.91 mm (+/- 0.71). T(0), T(1) and T(+1) implants presented with a mean biologic width of 1.97mm (+/- 1.20), 2.70 mm (+/- 1.36) and 2.84mm (+/- 0.90), respectively, with a connective tissue adaptation compartment of 1.21mm (+/- 0.97), 1.21 mm (+/- 0.65) and 1.50 mm (+/- 0.70) and an epithelial attachment of 0.84 mm (+/- 0.93), 1.66 mm (+/- 0.88) and 1.35 mm (+/- 0.44), respectively. Differences between the configurations were mainly associated with the length of the epithelial attachment. The epithelial attachment was significantly longer in the C sites than in T(0) (P = 0.014). However, no other differences between configurations were detected. Conclusion: If the implants are positioned at the level of the alveolar bony crest, the platform switching concept may have a minor impact on the length of the epithelial attachment (0.84 vs. 1.91 mm), while the connective tissue adaptation compartment remains relatively unaffected. Moreover, platform switching resulted in less resorption of the alveolar crest (0.58 mm).
Resumo:
Background and Objectives: - The effects of associating lipophilic opioids to local anesthetics in epidural anesthesia are not well defined. There are still questions and controversies about opioid doses to be used and their major effects in the epidural block. This study aimed at evaluating the epidural block effects in humans of the association of different fentanyl and sufentanil doses to bupivacaine with 1:200.000 epinephrine. Methods: - A double-blind randomized study was performed in 94 patients of both genders, physical status ASA I, aged between 18 and 60 years, submitted to lower abdomen, perineal or lower limb surgery. Patients without preanesthetic medication were epidurally injected with 100 mg (20 ml) 0.5% bupivacaine, 0.1 mg (0.1 ml) 1%o epinephrine plus a combination of the following drugs: BUPI Group (15 patients): 2 ml of 0.9% saline solution (SS); FENT50 Group (19 patients): 50 μg (1 ml) fentanyl + 1 ml SS; FENT100 Group (20 patients): 100 μg (2 ml) fentanyl; SUF30 Group (20 patients): 30 μg (0.6 ml) sufentanil + SS (1.4 ml); SUF100 Group (20 patients): 50 μg (1 ml) sufentanil + SS (1 ml). The following parameters were studied: onset of sensory block, analgesic block (onset time) in T12, T10 and T8, analgesic block duration in T10 and T12, motor block degree, consciousness degree, need for supplemental perioperative sedation and analgesia, hypotension, bradycardia and peri and post operative side-effects, analgesia duration, proportion of patients needing supplemental analgesia and evaluation of postoperative pain (pain analog visual scale). Results: Groups were demographically uniform. The addition of fentanyl or sufentanil did not alter major characteristics of perioperative epidural block and has not significantly increased postoperative analgesia duration as compared to the use of bupivacaine only. However, the addition of lipophilic opioids has increased the quality of perioperative anesthetic block, translated into a lesser need for supplemental analgesia (p < 0.02). The increased dose of fentanyl and especially of sufentanil has increased the incidence of perioperative drowsiness (p < 0.001) without significant increase in other side effects. Conclusions: In the conditions and doses used, the addition of lipophilic opioids to bupivacaine and the increased dose of lipophilic opioids have improved anesthetic block quality without changes in the epidural block characteristics or a significant increase in side effects, with the exception of drowsiness mainly caused by sufentanil. However, they were not able to provide a significant increase in postoperative analgesia duration.