997 resultados para optical parametric chirped-pulse amplification
Resumo:
Chaotic systems, when used to drive copies of themselves (or parts of themselves) may induce interesting behaviors in the driven system. In case the later exhibits invariance under amplification or translation, they may show amplification (reduction), or displacement of the attractor. It is shown how the behavior to be obtained is implied by the symmetries involved. Two explicit examples are studied to show how these phenomena manifest themselves under perfect and imperfect coupling.
Resumo:
Land use/cover classification is one of the most important applications in remote sensing. However, mapping accurate land use/cover spatial distribution is a challenge, particularly in moist tropical regions, due to the complex biophysical environment and limitations of remote sensing data per se. This paper reviews experiments related to land use/cover classification in the Brazilian Amazon for a decade. Through comprehensive analysis of the classification results, it is concluded that spatial information inherent in remote sensing data plays an essential role in improving land use/cover classification. Incorporation of suitable textural images into multispectral bands and use of segmentation‑based method are valuable ways to improve land use/cover classification, especially for high spatial resolution images. Data fusion of multi‑resolution images within optical sensor data is vital for visual interpretation, but may not improve classification performance. In contrast, integration of optical and radar data did improve classification performance when the proper data fusion method was used. Among the classification algorithms available, the maximum likelihood classifier is still an important method for providing reasonably good accuracy, but nonparametric algorithms, such as classification tree analysis, have the potential to provide better results. However, they often require more time to achieve parametric optimization. Proper use of hierarchical‑based methods is fundamental for developing accurate land use/cover classification, mainly from historical remotely sensed data.
Resumo:
RESUME : La ghrelin est un peptide sécrété par l'estomac jouant un rôle important dans le maintien de l'homéostasie énergétique. Ses taux plasmatiques sont augmentés durant des périodes prolongées de déficit nutritionnel. Une carence énergétique étant souvent associée à une inhibition de l'axe hypothalamo-hypophyso-ovarien, nous avons postulé que l'augmentation des taux circulant de ghrelin pourrait diminuer l'activité du générateur hypothalamique de pulsations de GnRH. Le protocole expérimental impliquait des singes rhésus adultes ovariectomisés (n=6) qui dans un premier temps recevaient durant 3 heures une perfusion de solution saline physiologique afin de mesurer la sécrétion pulsatile de LH à l'état basai. L'expérience se poursuivait alors durant 5 heures par une perfusion intraveineuse de ghrelin humaine (un bolus de 100-150µg suivi par 100-150µg/h) ou le maintien de la perfusion de solution saline physiologique. Des échantillons de sang étaient prélevés toutes les 15 minutes. La perfusion de ghrelin a augmenté ses taux plasmatiques de 2.9 fois par rapport aux valeurs de base. L'administration de ghrelin a significativement diminué la fréquence des pulsations de LH (de 0.89±0.07/h à l'état basai à 0.57±0.10/h durant la perfusion de ghrelin; p<0.05, moyenne±SEM), alors que la fréquence des pulsations de LH est restée inchangée durant la perfusion de solution physiologique. L'amplitude des pulsations de LH n'a pas été modifiée. La ghrelin a également stimulé de manière significative la sécrétion de cortisol et d'hormone de croissance, mais n'a toutefois pas eu d'effet sur la sécrétion de leptin. En conclusion, la ghrelin peut inhiber l'activité du générateur de pulsations de GnRH et pourrait ainsi contribuer à l'inhibition de l'axe de la reproduction observée durant des périodes de carence nutritionnelle, comme notamment chez les patientes souffrant d'anorexie mentale. La ghrelin peut également activer l'axe hypothalamo-hypophyso-surrénalien. Le lien dans cette situation entre l'activation de l'axe surrénalien et l'inhibition de l'axe de la reproduction reste à démontrer. ABSTRACT: Ghrelin, a nutrition-related peptide secreted by the stomach, is elevated during prolonged food deprivation. Because undernutrition is often associated with a suppressed reproductive axis, we have postulated that increasing peripheral ghrelin levels will decrease the activity of the GnRH pulse generator. Adult ovariectomized rhesus monkeys (n = 6) were subjected to a 5-h iv human ghrelin (100- to 150µg bolus followed by 100-150 µg/h) or saline infusion, preceded by a 3-h saline infusion to establish baseline pulsatile LH release. Blood samples were collected at 15-min intervals throughout the experiment. Ghrelin infusion increased plasma ghrelin levels 2.9-fold of baseline. Ghrelin significantly decreased LH pulse frequency (from 0.89 ± 0.07/h in baseline to 0.57 ± 0.10/h during ghrelin infusion; P<0.05, mean ± SEM), whereas LH pulse frequency remained unchanged during saline treatment. LH pulse amplitude was not affected. Ghrelin also significantly stimulated both Cortisol and GH release, but had no effect on leptin. We conclude that ghrelin can inhibit GnRH pulse activity and may thereby mediate the suppression of the reproductive system observed in conditions of undernutrition, such as in anorexia nervosa. Ghrelin also activates the adrenal axis, but the relevance of this to the inhibition of GnRH pulse frequency remains to be established.
Resumo:
Electrical deep brain stimulation (DBS) is an efficient method to treat movement disorders. Many models of DBS, based mostly on finite elements, have recently been proposed to better understand the interaction between the electrical stimulation and the brain tissues. In monopolar DBS, clinically widely used, the implanted pulse generator (IPG) is used as reference electrode (RE). In this paper, the influence of the RE model of monopolar DBS is investigated. For that purpose, a finite element model of the full electric loop including the head, the neck and the superior chest is used. Head, neck and superior chest are made of simple structures such as parallelepipeds and cylinders. The tissues surrounding the electrode are accurately modelled from data provided by the diffusion tensor magnetic resonance imaging (DT-MRI). Three different configurations of RE are compared with a commonly used model of reduced size. The electrical impedance seen by the DBS system and the potential distribution are computed for each model. Moreover, axons are modelled to compute the area of tissue activated by stimulation. Results show that these indicators are influenced by the surface and position of the RE. The use of a RE model corresponding to the implanted device rather than the usually simplified model leads to an increase of the system impedance (+48%) and a reduction of the area of activated tissue (-15%).
Resumo:
We present the optical properties of Na0.7CoO2 single crystals, measured over a broad spectral range as a function of temperature (T). The capability to cover the energy range from the far-infrared up to the ultraviolet allows us to perform reliable Kramers-Kronig transformation, in order to obtain the absorption spectrum (i.e., the complex optical conductivity). To the complex optical conductivity we apply the generalized Drude model, extracting the frequency dependence of the scattering rate (Gamma) and effective mass (m*) of the itinerant charge carriers. We find that Gamma(omega) at low temperatures and for similar to omega. This suggests that Na0.7CoO2 is at the verge of a spin-density-wave metallic phase.
Resumo:
Spodoptera frugiperda is a pest of great economic importance in the Americas. It is attacked by several species of parasitoids, which act as biological control agents. Parasitoids are morphologically identifiable as adults, but not as larvae. Laboratory rearing conditions are not always optimal to rear out parasitic wasps from S. frugiperda larvae collected from wild populations, and it frequently happens that parasitoids do not complete their life cycle and stop developing at the larval stage. Therefore, we explored ways to identify parasitoid larvae using molecular techniques. Sequencing is one possible technique, yet it is expensive. Here we present an alternate, cheaper way of identifying seven species of parasitoids (Cotesia marginiventris, Campoletis sonorensis, Pristomerus spinator, Chelonus insularis, Chelonus cautus, Eiphosoma vitticolle and Meteorus laphygmae) using PCR amplification of COI gene followed by a digestion with a combination of four restriction endonucleases. Each species was found to exhibit a specific pattern when the amplification product was run on an agarose gel. Identifying larvae revealed that conclusions on species composition of a population of parasitic wasps can be biased if only the emerging adults are taken into account.
Resumo:
Purpose: To evaluate the reproducibility of Cirrus-SD OCT measurements and to compare central macular thickness (CMT) measurements between TD-Stratus and SD-Cirrus OCT in patients with active exudative AMD. Methods: Consecutive case series of patients with active exudative AMD seen in the Medical Retina Department. Patients underwent 1 scan with Stratus (macular thickness map protocol) and 5 scans with Cirrus (Macular Cube protocol) at the same visit by the same experienced examiner. To be included, patients best-corrected visual acuity (BCVA) had to be >20/200 while all scans had to be of sufficient quality, well-centered and at least one Cirrus scan with CMT >300 microns. The repeatability of the SD Cirrus was estimated by using all 5 CMT measurements and the mean of the Cirrus measurements was compared with the CMT obtained by TD Stratus. Results: Cirrus OCT demonstrated high intraobserver repeatability at the central foveal region (ICC 96%). The mean of the CMT measurements was 321microns for Stratus and 387 microns for Cirrus. The average difference was 65m (SD=30). The coefficient of concordance between Stratus and Cirrus CMT measurements was rho=0,749 with a high precision and a moderate accuracy. The equation of the line of regression between Stratus and meanCirrus is given by the following: M_stratus = 0,848 x m_cirrus - 4,496 (1).Conclusions: The Cirrus macular cube protocol allows reproducible CMT measurements in patients with active exudative AMD. In cases of upgrading from TD to SD use and vice versa, there is the possibility to predict the measurements by using the equation (1). These real life data and conclusions can help in improving our clinical management of patients with neovascular AMD.
Resumo:
PURPOSE: To report the time course of retinal morphologic changes in a patient with acute retinal pigment epithelitis (ARPE) using spectral domain optical coherence tomography (SD-OCT). METHODS: A 30-year old man was referred for blurred vision of his right eye after five days that appeared suddenly 15 days after recovery from a flu-like syndrome. SD-OCT was performed immediately, followed by fluorescein and infracyanine angiography at eight days and then at three weeks. RESULTS: At presentation, a bubble of sub-macular deposit was observed on the right macula with central golden micronodules in a honeycomb pattern. SD-OCT showed an "anterior dislocation" of all the retinal layers up to the inner/outer segment (IS/OS) line and irregular deposits at the OS level together with thickening of the retinal pigment epithelial (RPE) layer. As visual acuity increased, eight days later, the OCT showed reduction of the sub-retinal deposits and an abnormal hyperflectivity of the sub-retinal and RPE layers was observed. The patient showed a positive serology for picornavirus. DISCUSSION: The acute SD-OCT sections of this patient with ARPE were compared with histological sections of a 35 day old Royal College of Surgeons rat. Similar findings could be observed, with preservation of the IS/OS line and accumulation of debris at the OS level, suggesting that ARPE symptoms could result from a transient phagocytic dysfunction of the RPE at the fovea, inducing reversible accumulation of undigested OS. Picornaviruses comprising enterovirus and coxsachievirus described as being associated with acute chorioretinitis. In this case, it was responsible for ARPE. CONCLUSION: We hypothesize that ARPE syndrome results from a transient dysfunction of RPE, which can occur as a post viral reaction.
Resumo:
We tested the hypothesis that hyperoxemia defined as arterial PO2 above 12 kPa can be detected by pulse oximetry using 95% oxygen saturation as the upper limit. Thirty artificially ventilated neonates with an indwelling arterial catheter were studied registrating transcutaneous oxygen saturation (Ohmeda Biox 3700 Pulse Oximeter) and transcutaneous PO2 continuously during a 4-hour period and measuring arterial oxygen saturation and PO2 intermittently. 46 episodes of arterial hyperoxemia were observed. Pulse oximetry had a sensitivity of 30%, detecting 14 of these 46 hyperoxemic episodes, and a specificity of 93%. The accuracy for separating hyperoxemia from normoxemia by pulse oximetry could be improved by shifting the cut-off point from 95% to 92%. With this optimal cut-off point sensitivity was 70% and specificity 62%. We conclude that pulse oximetry is not reliable for detection of hyperoxemia.
Resumo:
PURPOSE: Intravenous (i.v.) pulse of corticosteroids has been used to treat severe eye inflammation from different origins. Whether such large doses result in vitreous levels that differ either in magnitude or duration from more conventional corticotherapy remain unsolved issues. The authors therefore determined levels of methylprednisolone hemisuccinate and methylprednisolone in the vitreous and serum of patients at different times after a single i.v. perfusion of methylprednisolone hemisuccinate. METHODS: Fifty patients scheduled for a first vitrectomy received an i.v. injection of 500 mg hemisuccinate methylprednisolone at different times before surgery (from 15-24 hours). Patients were divided into two groups: those with (n = 21) and without (n = 29) retinal detachment (RD). Pure vitreous samples were analyzed by high-pressure liquid chromatography. RESULTS: Both the ester and the nonester methylprednisolone forms were sampled in the vitreous, showing a slower rate of hydrolysis compared to the serum. On average, the highest concentration of total methylprednisolone in the vitreous was found at 2.5 hours and rapidly decreased for the group of patients with RD. In the group of patients without RD, the highest concentration was reached at 6 hours and then slowly decreased. The antiinflammatory potency in the nondetached retina eyes was approximately 500 times more than in the physiologic vitreous, but despite the route of administration (i.v. or oral), only 1/10 of the corticosteroid serum concentration was measured in the vitreous. CONCLUSION: High concentration of methylprednisolone is achieved by i.v. pulse therapy without changing the kinetic of entry in the vitreous of nondetached retina eyes when compared to conventional oral corticotherapy. Hydrolysis occurs in the vitreous resulting in high rate of active form. Pulse therapy could be considered in cases of severe ocular inflammation involving the posterior segment of the eye.
Resumo:
This thesis considers nondestructive optical methods for metal surface and subsurface inspection. The main purpose of this thesis was to study some optical methods in order to find out their applicability to industrial measurements. In laboratory testing the simplest light scattering approach, measurement of specular reflectance, was used for surface roughness evaluation. Surface roughness, curvature and finishing process of metal sheets were determined by specular reflectance measurements. Using a fixed angleof incidence, the specular reflectance method might be automated for industrialinspection. For defect detection holographic interferometry and thermography were compared. Using either holographic interferometry or thermography, relativelysmall-size defects in metal plates could be revealed. Holographic techniques have some limitations for industrial measurements. On the contrary, thermography has excellent prospects for on-line inspection, especially with scanning techniques.
Resumo:
In this paper, the sensor of an optical mouse is presented as a counterfeit coin detector applied to the two-Euro case. The detection process is based on the short distance image acquisition capabilities of the optical mouse sensor where partial images of the coin under analysis are compared with some partial reference coin images for matching. Results show that, using only the vision sense, the counterfeit acceptance and rejection rates are very similar to those of a trained user and better than those of an untrained user.
Resumo:
The following paper introduces the work conducted to create a relative virtual mouse based on the interpretation of head movements and face gesture through a low cost camera and the optical flow of the images. This virtual device is designed specifically as an alternative non-contact pointer for people with mobility impairments in the upper extremities and reduced head control. The proposed virtual device was compared with a conventional mouse, a touchpad and a digital joystick. Validation results show performances close to a digital joystick but far away from a conventional mouse.
Resumo:
OBJECTIVES: To explore the association of short-term exposure to particulate matter with aerodynamic diameters less than 10 μm (PM10) with pulse pressure, SBP, and DBP taking outdoor temperature into account in two large population-based studies in Switzerland. METHODS: We used data from the Bus Santé study including 5605 adults in Geneva and the CoLaus study including 6183 adults in Lausanne. PM10 and meteorological data were measured from fixed monitoring stations. We analyzed the association of short-term exposure to PM10 (on the day of examination visit and up to 7 days before) with pulse pressure, SBP, and DBP by linear regression, controlling for potential confounders and effect modifiers. RESULTS: Average PM10 levels were 22.4 μg/m in Geneva and 31.7 μg/m in Lausanne. In adjusted models, for each 10 μg/m increase in 7-day PM10 average, pulse pressure and SBP increased by 0.583 (95% confidence interval, 0.296-0.870) mmHg and 0.490 (0.056-0.925) mmHg in Geneva, and 0.183 (0.017-0.348) mmHg and 0.036 (0.042-0.561) mmHg in Lausanne, respectively. Stronger associations of pulse pressure and SBP with PM10 were observed when outdoor temperature was above 5°C. CONCLUSION: Positive associations of pulse pressure and SBP with short-term exposure to PM10 were found and replicated in the Swiss adult population. Our results suggest that even low levels of air pollution may substantially impact cardiovascular risk in the general population.
Resumo:
BACKGROUND: Chronic kidney disease (CKD) accelerates vascular stiffening related to age. Arterial stiffness may be evaluated measuring the carotid-femoral pulse wave velocity (PWV) or more simply, as recommended by KDOQI, monitoring pulse pressure (PP). Both correlate to survival and incidence of cardiovascular disease. PWV can also be estimated on the brachial artery using a Mobil-O-Graph; a non-operator dependent automatic device. The aim was to analyse whether, in a dialysis population, PWV obtained by Mobil-O-Graph (MogPWV) is more sensitive for vascular aging than PP. METHODS: A cohort of 143 patients from 4 dialysis units has been followed measuring MogPWV and PP every 3 to 6 months and compared to a control group with the same risk factors but an eGFR > 30 ml/min. RESULTS: MogPWV contrarily to PP did discriminate the dialysis population from the control group. The mean difference translated in age between the two populations was 8.4 years. The increase in MogPWV, as a function of age, was more rapid in the dialysis group. 13.3% of the dialysis patients but only 3.0% of the control group were outliers for MogPWV. The mortality rate (16 out of 143) was similar in outliers and inliers (7.4 and 8.0%/year). Stratifying patients according to MogPWV, a significant difference in survival was seen. A high parathormone (PTH) and to be dialysed for a hypertensive nephropathy were associated to a higher baseline MogPWV. CONCLUSIONS: Assessing PWV on the brachial artery using a Mobil-O-Graph is a valid and simple alternative, which, in the dialysis population, is more sensitive for vascular aging than PP. As demonstrated in previous studies PWV correlates to mortality. Among specific CKD risk factors only PTH is associated with a higher baseline PWV. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02327962.