957 resultados para nuclear pores
Resumo:
Não disponível
Resumo:
Nuclear medicine uses non-sealed sources for exams and treatments, because the movement of these sources, source of patients injected or not, involve a wide range of environmental radiometric levels. To better control of these levels this study was aimed at monitoring points strategically distributed in all environments Sector Technical Nuclear Medicine, Hospital of the Botucatu Medical School, performing two measurements at random times daily for a period of three months, sampling the normal routine of the sector. The detector Geiger-Muller was used for the acquisition of exposure rates of the points, efficiency and reprodutibility test have shown good performance of this equipment for this purpose. The results allowed to make a projection of annual dose for each environment indicating higher risks for Occupationally Exposed Individuals as well as Public Individuals compared with the limits established by the National Commission of Nuclear Energy. Was developed a spatial map of dose that can be used as a visual warning to the regions with the highest exposure to ionizing radiation, enabling reduced risk of a potential exposure
Resumo:
Proteínas que apresentam atividades no núcleo e possuem sequência de localização nuclear (NLS) tem seu deslocamento dependente do heterodímero importina-α/β. A importina- (ImpA) é responsável pelo reconhecimento inicial do substrato a ser importado através da interação com os NLS. Os sinais são caracterizados por apresentar um ou mais grupos de aminoácidos básicos, denominados como sequências monopartidas e bipartidas. O fungo Neurospora crassa vem sendo utilizado há mais de 70 anos como organismo modelo em estudos de expressão gênica, desenvolvimento e diferenciação celular, ritmo circadiano, defesa do genoma, bem como outros aspectos da biologia de eucariotos. A presença de um grande número de genes no genoma de N. crassa ainda com funções desconhecidas aponta este organismo como um promissor modelo para o estudo de novos mecanismos genéticos e bioquímicos ainda não identificados. Considerando a importância do metabolismo do glicogênio para os organismos, o presente trabalho teve como objetivo o estudo estrutural de complexos de ImpA com peptídeos NLSs (NCM e NCB) de proteínas envolvidas no metabolismo de glicogênio do fungo N. crassa, utilizando técnicas de cristalografia de proteínas. Monocristais dos complexos ImpA-NCM e ImpA-NCB foram obtidos para a coleta dos dados de difração de raios-X, resultando em dois conjuntos de dados à 2,1Å e 2,45Å de resolução, respectivamente. Após elucidação da estrutura da ImpA, mapas de densidade eletrônica gerados revelaram uma densidade eletrônica no sítio principal de reconhecimento de NLS da ImpA de ambas estruturas, possibilitando modelagem dos peptídeos. Em uma comparação do mapa de densidade eletrônica obtido de ambos complexos com um mapa de uma estrutura nativa de ImpA (70-529) coletada à 2,0Å de resolução, a qual usualmente apresenta um peptídeo “contaminante” no sitio de ligação... (Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
Since its discovery, radioactivity has brought numerous benefits to human societies. It has many applications in medicine, serving as a tool for non-invasive methods for diagnosis and therapies against diseases such as cancer. It also applies to technologies for energy in nuclear power plants with relatively low impacts on terms of perfect security. All applications, however, have risks, requiring maximum caution to drive processes and operations involving radioactive elements because, once released into the environment, they have extremely harmful effects on organisms affected. This paper presents fundamental concepts and principles of nuclear physics in order to understand the effects of radioactive elements released into the environment, culminating on the issue of radioactive contamination. Literature review allowed us to understand the radioactive contamination problem on living beings. Three major nuclear accidents have happened in the last thirty years, two of them in consecutive years. The nuclear accident at Chernobyl, Ukraine, in 1986, polluted large areas, condemning hundreds of thousands of people to live with consequences of the accident and effects of radiation, killing thousands of people throughout the years. In 1987, a major radiological accident occurred in Goiania (GO) when a source of radioactive cesium was violated, leading to the death of those who had direct or indirect contact with cesium. The most recent accident, in March, 2011, was located at the nuclear power plant in Fukushima Prefecture, Japan, after an earthquake and tsunami hit the region. There is no extensive and accurate knowledge about the consequences of the contamination entailed in that accident, although it is possible to verify signals on a global scale. An analysis of reports of contamination of large areas generated by nuclear plants with release of hazardous wastes suggests it is necessary to rethink the energy matrix of the various countries...
Resumo:
The Therapy with proton beam has shown more e ective than Radiotherapy for oncology treatment. However, to its planning use photon beam Computing Tomography that not considers the fundamentals di erences the interaction with the matter between X-rays and Protons. Nowadays, there is a great e ort to develop Tomography with proton beam. In this way it is necessary to know the most likely trajectory of proton beam to image reconstruction. In this work was realized calculus of the most likely trajectory of proton beam in homogeneous target compound with water that was considered the inelastic nuclear interaction. Other calculus was the analytical calculation of lateral de ection of proton beam. In the calculation were utilized programs that use Monte Carlo Method: SRIM 2006 (Stopping and Range of Ions in Matter ), MCNPX (Monte Carlo N-Particle eXtended) v2.50. And to analytical calculation was employed the software Wolfram Mathematica v7.0. We obtained how di erent nuclear reaction models modify the trajectory of proton beam and the comparative between analytical and Monte Carlo method
Resumo:
The goal of this work is to study the process of interaction of protons with matter through Monte Carlo simulation. For this purpose, it was employed the SRIM program (Stopping and Range of Ions in Matter ) and MCNPX (Monte Carlo N-Particle eXtended) v2.50. This work is going to support the development of a tomography system with protons. It was studied the interaction of proton with the follow materials: Polimethyl Mehacralate (PMMA), MS20 Tissue Substitute and water. This work employed energies in range of 50 MeV and 250 MeV, that is the range of clinical interest. The energy loss of proton after cross a material layer, the decreasing of its intensity, the angular and lateral de ection of incident beam, including and excluding nuclear interactions. This work is related with Medical Physics and Material Physics, like interaction of radiation with matter, particle transport phenomena, and the experimental methods in Nuclear Physics like simulation and computational by Monte Carlo method
Resumo:
After the discovery of ionizing radiation, its applications in various fields of science began to take significant proportions. In the case of medicine, there are the application areas in radiotherapy, diagnostic radiology and nuclear medicine. It was then necessary to create the field of radiological protection to establish the conditions necessary for the safe use of such ionizing radiation. Apply knowledge obtained during the graduation stage and in the practice of radiological protection in the areas of nuclear medicine and diagnostic radiology. In the area of nuclear medicine, tests were made in the Geiger-Muller counters (GM) and the dose calibrator (curiometer), the monitoring tests of radiation, waste management, clean of the Therapeutic room and testing the quality control of gamma-chambers. In the area of radiology, were performed tests of quality control equipment for conventional X-ray equipment and x-ray fluoroscopy, all following the rules of the National Health Surveillance Agency (ANVISA), and reporting of tests. The routine developed in the fields of nuclear medicine in hospitals has proved very useful, since the quality control of GM counters contribute to the values of possible contamination are more reliable. The control of dose calibrator enables the patient not to receive different doses of the recommended amounts, which prevents the repetition of tests and unnecessary exposure to radiation. The management of waste following the rules and laws established and required for its management. Tests for quality control of gamma chambers help to evaluate its medical performance through image. In part of diagnostic radiology, tests for quality control are performed in order to verify that the equipment is acceptable for usage or if repairs are needed. The knowledge acquired at the internship consolidated the learning of graduation course
Resumo:
Nuclear medicine is a medical specialty related to imagery that deals with imaging techniques, diagnosis and therapy, allowing observing the physiological state of tissues noninvasively by marking the molecules participating of these physiological processes with radioactive isotopes, thus creating the called radionuclides. The image of a radionuclide is one of the most important applications of radioactivity in nuclear medicine. The equipment’s of nuclear medicine imaging use the principle of radiation detection, turning it into an electrical signal which, through specific algorithms, allows forming tomographic images that provide information about the functional status of organs. New detection systems have been developed for tomographic acquisitions using solid state detectors. These devices use crystals of cadmium zinc telluride (CdZnTe). Some of the advantages of this detector are a significant improvement of signal to noise ratio, the increased spectral and spatial resolution, which in sum, result in greater clarity of the images obtained, opening new perspectives for imaging protocols previously unattainable. In contrast, all other gamma-cameras equipped with vacuum tubes have remained relatively unchanged for nearly fifty years. In these gamma-cameras, the images are obtained using two steps significantly less efficient: the gamma rays are converted to light through a first device, and then the light is converted into an electrical signal through a second device. One of functions the Medical Physicist is related to the quality control of equipment. This control ensures that the information and images provided are true and thus credible to be used in medical reports. To perform this type of analysis the physicist must understand the performance characteristics and operation of all equipment of the department concerned; besides, in the absence of specific legislation, proposing...(Complete abstract click electronic access below)
Resumo:
The plasma represents a average of the information referring biochemists to the physiology of the organism as a whole, therefore it indirectly or directly interacts with all tissues of the body. In such a way the plasma can be considered as a metabolic “soup”. Using the Nuclear Magnetic Resonance Spectroscopy sanguineous plasma spectra had been generated and using deconvolution techniques it was possible to know the contribution of the albumin for the formation of the spectra of the sanguineous plasma
Resumo:
O ambiente folicular é responsável por manter o oócito em parada meiótica e pela retomada da mesma posteriormente. A retomada da meiose em momento adequado é de extrema importância para o desenvolvimento de oócitos de alta competência. Portanto, o estudo dos mecanismos reguladores da retomada da meiose é de grande utilidade. Nesse estudo, os efeitos do FGF2, FGF10 e BMP15 sobre a progressão da meiose durante a maturação oocitária in vitro foram testados. Para tanto, complexos cumulus-oócitos (COCs) foram cultivados em meio definido seguindo o delineamento: Interação FGF10 e BMP15: sendo os tratamentos: controle; FGF10 (10ng/mL); BMP15 (100ng/mL); FGF10 (10ng/mL) + BMP15 (100ng/mL); e Dose-Resposta FGF2: sendo os tratamentos: controle e FGF2 nas doses 1, 10 ou 100ng/mL. A fase da meiose foi avaliada após 22h de cultivo por meio de coloração HOESCHT 33342, sendo os oócitos classificados em meiose I ou meiose II. O FGF10 (68%), a BMP15 (62,57%) ou a interação, FGF10+BMP15, (73%) não alteraram a porcentagem de oócitos em MII após a MIV em relação ao controle (69,63%). Assim como, a adição de FGF2 nas doses de 1ng/mL (81,33%), 10ng/mL (84,83%) ou 100ng/mL (83%) também não alteraram a porcentagem de oócitos em MII em relação ao controle (79,83%)
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
The noteworthy of this study is to predict seven quality parameters for beef samples using time-domain nuclear magnetic resonance (TD-NMR) relaxometry data and multivariate models. Samples from 61 Bonsmara heifers were separated into five groups based on genetic (breeding composition) and feed system (grain and grass feed). Seven sample parameters were analyzed by reference methods; among them, three sensorial parameters, flavor, juiciness and tenderness and four physicochemical parameters, cooking loss, fat and moisture content and instrumental tenderness using Warner Bratzler shear force (WBSF). The raw beef samples of the same animals were analyzed by TD-NMR relaxometry using Carr-Purcell-Meiboom-Gill (CPMG) and Continuous Wave-Free Precession (CWFP) sequences. Regression models computed by partial least squares (PLS) chemometric technique using CPMG and CWFP data and the results of the classical analysis were constructed. The results allowed for the prediction of aforementioned seven properties. The predictive ability of the method was evaluated using the root mean square error (RMSE) for the calibration (RMSEC) and validation (RMSEP) data sets. The reference and predicted values showed no significant differences at a 95% confidence level.