999 resultados para micro-finned tube


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To develop real-time simulations of wind instruments, digital waveguides filters can be used as an efficient representation of the air column. Many aerophones are shaped as horns which can be approximated using conical sections. Therefore the derivation of conical waveguide filters is of special interest. When these filters are used in combination with a generalized reed excitation, several classes of wind instruments can be simulated. In this paper we present the methods for transforming a continuous description of conical tube segments to a discrete filter representation. The coupling of the reed model with the conical waveguide and a simplified model of the termination at the open end are described in the same way. It turns out that the complete lossless conical waveguide requires only one type of filter.Furthermore, we developed a digital reed excitation model, which is purely based on numerical integration methods, i.e., without the use of a look-up table.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After digestion of infected meat the free L1 of Trichinella spp. penetrate the intestinal mucosa where they moult to the mature adult stage. We have used proteomics to identify changes in protein secretion during in vitro culture of free T. spiralis muscle larvae under different environmental conditions, and to correlate these changes with their infectivity in mice. Muscle larvae were cultured in different media (RPMI-1640, C-199 and HBSS) under conditions of anaerobiosis, microaerobiosis and in 5% CO(2) at 37 degrees C. Following incubation the larval excretory/secretory proteins were analysed by two-dimensional gel electrophoresis and the larvae were used to orally infect naïve CD1 mice. For all culture media tested, infectivity of the L1 was preserved following incubation in anaerobic conditions. In contrast, the infectivity of worms cultured in nutrient-rich media was almost completely abolished in both microaerobiosis and in the presence of 5% CO(2). Some infectivity was retained in poor or reduced culture media. Comparative analysis of larval infectivity and protein secretion showed that loss of infectivity correlated with the appearance of non-tyvelosylated proteins that in turn may be related to the onset of moulting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concentrations of a range of micro-organic compounds in the Humber rivers have been measured at weekly intervals over a period of 1 year. The compounds include the triazine herbicides (simazine, atrazine, propazine, desmetryn and prometryn), selected organophosphorus insecticides (fenitrothion, malathion and parathion), phenylurea (chlorotoluron, diuron, isoproturon and linuron) and phenoxyacid herbicides (2,4-D, MCPA, MCPB and mecoprop), phenol derivatives (phenol, 2-ethylphenol, 2-chlorophenol, 4-nitrophenol, 2-methylphenol, 4-ethylphenol and 2,4-dichlorophenol), organochlorine insecticides (HEOD, DDT, TDE, DDE, HCB, alpha-BHC and lindane), PCB's and some synthetic pyrethroid insecticides (cis/trans-permethrin, fenvalerate and cypermethrin). The results indicate the high frequency of occurrence of many compounds in the southern Humber rivers Aire, Calder, Trent and Don compared with the more occasional concentrations found in the upland rivers with catchments dominated by low intensity agriculture. The more water soluble herbicides, atrazine, simazine, isoproturon and diuron are detected frequently in the southern rivers with the highest concentrations and abundance in the rivers Aire, Calder and Trent. The most abundant phenolic compound is 2,4-dichlorophenol usually occurring at concentrations <1 mu g/l. The organochlorine insecticides and PCB's are generally at concentrations <0.01 mu g/l, cis/trans-permethrin are the only synthetic pyrethroids detected and these are found in the rivers Aire and Calder at about equal concentrations of between 0.01 and 0.11 mu g/l. The results of the occurrence of simazine and atrazine in the rivers Trent, Don and Aire illustrate peaks in concentration in the spring and then later in the year during the early autumn coinciding with the first major storm after the summer. In the rivers Trent and Don, the annual exports (March 1994-95) of atrazine are lower than for simazine whereas in the R. Calder the yield of atrazine is higher than for simazine suggesting differences in use in these catchments. The maximum triazine concentration observed, i.e. 8 mu g/l of atrazine in the R. Calder, could have inhibiting effects on the phytoplankton and algal growth, although because of the transient nature of the peaks, recovery is expected to be rapid. The only other compounds measured at concentrations likely to produce detrimental ecotoxicological effects are cis/trans permethrin in the rivers Aire and Calder. (C) 1997 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gas-liquid processing in microreactors remains mostly restricted to the laboratory scale due to the complexity and expenditure needed for an adequate numbering-up with a uniform flow distribution. Here, the numbering-up is presented for multi-phase (gas-liquid) flow in microreactor suitable for a production capacity of kg/h. Based on the barrier channels concept, the barrier-based micro/milli reactor (BMMR) is designed and fabricated to deliver flow non-uniformity of less than 10%. The BMMR consists of eight parallel channels all operated in the Taylor flow regime and with a liquid flow rate up to 150. mL/min. The quality of the flow distribution is reported by studying two aspects. The first aspect is the influence of different viscosities, surface tensions and flow rates. The second aspect is the influence of modularity by testing three different reaction channels type: (1) square channels fabricated in a stainless steel plate, (2) square channels fabricated in a glass plate, and (3) circular channels (capillaries) made of stainless steel. Additionally, the BMMR is compared to that of a single channel regard the slug and bubble lengths and bubble generation frequency. The results pave the ground for bringing multi-phase flow in microreactor one step closer for large scale production via numbering-up. © 2012 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes an optimisation of the adaptive Gaussian mixture background model that allows the deployment of the method on processors with low memory capacity. The effect of the granularity of the Gaussian mean-value and variance in an integer-based implementation is investigated and novel updating rules of the mixture weights are described. Based on the proposed framework, an implementation for a very low power consumption micro-controller is presented. Results show that the proposed method operates in real time on the micro-controller and has similar performance to the original model. © 2012 Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report a new technique to correct tube position in anterior chamber after glaucoma drainage device implantation.

PATIENT AND METHODS: A patient who underwent a glaucoma drainage device implantation was noted to have the tube touching the corneal endothelium. A 10/0 polypropylene suture with double-armed 3-inch long straight needle was placed transcamerally from limbus to limbus, in the superior part of the eye, passing the needle in front of the tube.

RESULTS: The position of the tube in the anterior chamber was corrected with optimal distance from corneal endothelium and iris surface. The position remained satisfactory after 20 months of follow-up.

CONCLUSIONS: The placement of a transcameral suture offers a safe, quick, and minimal invasive intervention for the correction of the position of a glaucoma drainage device tube in the anterior chamber.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients with spontaneous lens dislocation and glaucoma can be challenging to manage. We present a forty-six year old Caucasian lady who was referred with bilateral high intraocular pressure, and was subsequently diagnosed with glaucoma in association with lens dislocation and Marfan syndrome. Baerveldt glaucoma drainage device tubes were inserted in both eyes due to poor response to medical therapy. However, this was complicated by recurrent vitreous occlusion of both glaucoma drainage tubes requiring further multiple surgical interventions. There have not been any further recurrences of vitreous incarceration or posterior segment complications since, but the patient remains under close follow-up. © 2010 Ang et al; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 42-year-old man has been under long-term follow-up since he was a child for congenital glaucoma and buphthalmos in both eyes. His left eye best corrected visual acuity (BCVA) was counting fingers, due to end-stage glaucoma. He was on maximal medical therapy with an intraocular pressure (IOP) maintained at mid to low twenties. His right eye, the only seeing eye, had a BCVA of 6/9. This eye had undergone multiple glaucoma laser and surgical procedures, including an initial first Molteno drainage device inserted superonasally that failed in April 2003 due to fibrotic membrane over the tube opening. As a result, he subsequently had a second Molteno drainage device inserted inferotemporally. To further maximize his vision he had an uncomplicated cataract extraction and intraocular lens implant in December 2004, after which he developed postoperative cystoid macular edema and corneal endothelial failure. He underwent a penetrating keratoplasty in the right eye thereafter in March 2007. After approximately a year, the second Molteno device developed drainage tube retraction, which was managed surgically to maintain optimum IOP in the right eye. His right eye vision to date is maintained at 6/12. © 2011 Mustafa and Azuara-Blanco.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose . To investigate alternative surgical method to cover subconjunctival portion of the tube in tube shunt surgery in glaucoma Methods. In thirteen eyes of twelve patients who underwent tube shunt surgery at WEH between July 1991 to November 1996 a "rotating" autologous scleral lamellar graft was created to cover the subconjuctival course of the tube. These patients were followed for clinical signs of conjuctival breakdown, graft melt, tube erosion, anterior staphylomas, graft related inflammation, infections or graft related complications. Results. The patients were followed up for a mean of 16 5 months( range 1-60 months). All eyes tolerated the autologous graft well without any clinical evidence of tube erosions, graft melting , graft related or intraocular inflammation Conclusions The use of autologous sciera, to cover the tube in a tube shunt procedure appears to be effective and without inappropriate short term risk. It offers the advantages of availability , lower cost, and eliminates the potential risk of transmission of infectious disease( i.e. slow-virus, HIV etc.).