965 resultados para method applied to liquid samples


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capturing the voices of women when the issue is of a sensitive nature has been a major concern of feminist researchers. It has often been argued that interpretive methods are the most appropriate way to collect such information, but there are other appropriate ways to approach the design of research. This article explores the use of a mixed-method approach to collect data on incontinence in older women and argues for the use of a variety of creative approaches to collect and analyze data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper evaluates a new, low-frequency finite-difference time-domain method applied to the problem of induced E-fields/eddy currents in the human body resulting from the pulsed magnetic field gradients in MRI. In this algorithm, a distributed equivalent magnetic current is proposed as the electromagnetic source and is obtained by quasistatic calculation of the empty coil's vector potential or measurements therein. This technique circumvents the discretization of complicated gradient coil geometries into a mesh of Yee cells, and thereby enables any type of gradient coil modelling or other complex low frequency sources. The proposed method has been verified against an example with an analytical solution. Results are presented showing the spatial distribution of gradient-induced electric fields in a multi-layered spherical phantom model and a complete body model. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The aim of this study was to determine the effects of carvedilol on the costs related to the treatment of severe chronic heart failure (CHF). Methods: Costs for the treatment for heart failure within the National Health Service (NHS) in the United Kingdom (UK) were applied to resource utilisation data prospectively collected in all patients randomized into the Carvedilol Prospective Randomized Cumulative Survival (COPERNICUS) Study. Unit-specific, per them (hospital bed day) costs were used to calculate expenditures due to hospitalizations. We also included costs of carvedilol treatment, general practitioner surgery/office visits, hospital out-patient clinic visits and nursing home care based on estimates derived from validated patterns of clinical practice in the UK. Results: The estimated cost of carvedilol therapy and related ambulatory care for the 1156 patients assigned to active treatment was 530,771 pound (44.89 pound per patient/month of follow-up). However, patients assigned to carvedilol were hospitalised less often and accumulated fewer and less expensive days of admission. Consequently, the total estimated cost of hospital care was 3.49 pound million in the carvedilol group compared with 4.24 pound million for the 1133 patients in the placebo arm. The cost of post-discharge care was also less in the carvedilol than in the placebo group (479,200 pound vs. 548,300) pound. Overall, the cost per patient treated in the carvedilol group was 3948 pound compared to 4279 pound in the placebo group. This equated to a cost of 385.98 pound vs. 434.18 pound, respectively, per patient/month of follow-up: an 11.1% reduction in health care costs in favour of carvedilol. Conclusions: These findings suggest that not only can carvedilol treatment increase survival and reduce hospital admissions in patients with severe CHF but that it can also cut costs in the process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper evaluates a low-frequency FDTD method applied to the problem of induced E-fields/eddy currents in the human body resulting from the pulsed magnetic field gradients in MRI. In this algorithm, a distributed equivalent magnetic current (DEMC) is proposed as the electromagnetic source and is obtained by quasistatic calculation of the empty coil's vector potential or measurements therein. This technique circumvents the discretizing of complicated gradient coil geometries into a mesh of Yee cells, and thereby enables any type of gradient coil modeling or other complex low frequency sources. The proposed method has been verified against an example with an analytical solution. Results are presented showing the spatial distribution of gradient-induced electric fields in a multilayered spherical phantom model and a complete body model.