952 resultados para inter-ring variation
Resumo:
OBJECTIVE: To compare published guidelines concerning screening for gestational diabetes. STUDY DESIGN: Systematic search and comparative analysis of published guidelines. Appraisal of guidelines quality. Simulation analysis. RESULTS: Ten published guidelines proposed either universal screening (5), selective screening (3) or screening when clinically indicated (2). Variations of testing schedules and blood glucose thresholds were observed. The quality of the published guidelines was low, on average 22 (8-51) percentage points on the assessment scale. These differences would have led to large variations in the number of patients to be screened. CONCLUSIONS: Large variations between guidelines have been observed which would translate in large practice variations, if the guidelines were systematically applied. These variations are partially explained by the absence of definite evidence that universal or selective screening for gestational diabetes do more good than harm on infant and maternal health. The methodology of developing guidelines should be more evidence based, systematic and explicit.
Resumo:
Meropenem, a carbapenem antibiotic displaying a broad spectrum of antibacterial activity, is administered in Medical Intensive Care Unit to critically ill patients undergoing continuous veno-venous haemodiafiltration (CVVHDF). However, there are limited data available to substantial rational dosing decisions in this condition. In an attempt to refine our knowledge and propose a rationally designed dosage regimen, we have developed a HPLC method to determine meropenem after solid-phase extraction (SPE) of plasma and dialysate fluids obtained from patients under CVVHDF. The assay comprises the simultaneous measurement of meropenem's open-ring metabolite UK-1a, whose fate has never been studied in CVVHDF patients. The clean-up procedure involved a SPE on C18 cartridge. Matrix components were eliminated with phosphate buffer pH 7.4 followed by 15:85 MeOH-phosphate buffer pH 7.4. Meropenem and UK-1a were subsequently desorbed with MeOH. The eluates were evaporated under nitrogen at room temperature (RT) and reconstituted in phosphate buffer pH 7.4. Separation was performed at RT on a Nucleosil 100-5 microm C18 AB cartridge column (125 x 4 mm I.D.) equipped with a guard column (8 x 4 mm I.D.) with UV-DAD detection set at 208 nm. The mobile phase was 1 ml min(-1), using a step-wise gradient elution program: %MeOH/0.005 M tetrabutylammonium chloride pH 7.4; 10/90-50/50 in 27 min. Over the range of 5-100 microg ml(-1), the regression coefficient of the calibration curves (plasma and dialysate) were >0.998. The absolute extraction recoveries of meropenem and UK-1a in plasma and filtrate-dialysate were stable and ranged from 88-93 to 72-77% for meropenem, and from 95-104 to 75-82% for UK-1a. In plasma and filtrate-dialysate, respectively, the mean intra-assay precision was 4.1 and 2.6% for meropenem and 4.2 and 3.7% for UK-1a. The inter-assay variability was 2.8 and 3.6% for meropenem and 2.3 and 2.8% for UK-1a. The accuracy was satisfactory for both meropenem and UK-1a with deviation never exceeding 9.0% of the nominal concentrations. The stability of meropenem, studied in biological samples left at RT and at +4 degrees C, was satisfactory with < 5% degradation after 1.5 h in blood but reached 22% in filtrate-dialysate samples stored at RT for 8 h, precluding accurate measurements of meropenem excreted unchanged in the filtrate-dialysate left at RT during the CVVHDF procedure. The method reported here enables accurate measurements of meropenem in critically ill patients under CVVHDF, making dosage individualisation possible in such patients. The levels of the metabolite UK-1a encountered in this population of patients were higher than those observed in healthy volunteers but was similar to those observed in patients with renal impairment under hemodialysis.
Resumo:
The new-generation nebulizers are commonly used for the administration of salbutamol in mechanically ventilated patients. The different modes of administration and new devices have not been compared. We developed a liquid chromatography-tandem mass spectrometry method for the determination of concentrations as low as 0.05 ng/mL of salbutamol, corresponding to the desired plasma concentration after inhalation. Salbutamol quantification was performed by reverse-phase HPLC. Analyte quantification was performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection ESI in the positive mode. The method was validated over concentrations ranging from 0.05 to 100 ng/mL in plasma and from 0.18 to 135 ng/mL in urine. The method is precise, with mean inter-day coefficient of variation (CV%) within 3.1-8.3% in plasma and 1.3-3.9% in urine, as well as accurate. The proposed method was found to reach the required sensitivity for the evaluation of different nebulizers as well as nebulization modes. The present assay was applied to examine whether salbutamol urine levels, normalized with the creatinine levels, correlated with the plasma concentrations. A suitable, convenient and noninvasive method of monitoring patients receiving salbutamol by mechanical ventilation could be implemented. Copyright © 2011 John Wiley & Sons, Ltd.
Resumo:
The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3 +/- 3.4, coronary sinus 34.2 +/- 4.1, sino-tubular junction 29.7 +/- 3.4 and mid ascending aorta 32.7 +/- 3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6 +/- 11.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1 +/- 3.7, and between both coronary ostia 7.2 +/- 3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 +/- 9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.6 +/- 3.3, CV 13-43%. Mean aortic valve area was 582.0 +/- 131.9 mm(2). The variation of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.