996 resultados para implant dentistry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This retrospective study analyzed the pool of patients referred for treatment with dental implants over a 3-year period in a referral specialty clinic. Materials and Methods: All patients receiving dental implants between 2002 and 2004 in the Department of Oral Surgery and Stomatology, University of Bern, were included in this retrospective study. Patients were analyzed according to age, gender, indications for implant therapy, location of implants, and type and length of implants placed. A cumulative logistic regression analysis was performed to identify and analyze potential risk factors for complications or failures. Results: A total of 1,206 patients received 1,817 dental implants. The group comprised 573 men and 633 women with a mean age of 55.2 years. Almost 60% of patients were age 50 or older. The most frequent indication for implant therapy was single-tooth replacement in the maxilla (522 implants or 28.7%). A total of 726 implants (40%) were inserted in the esthetically demanding region of the anterior maxilla. For 939 implants (51.7%), additional bone-augmentation procedures were required. Of these, ridge augmentation with guided bone regeneration was performed more frequently than sinus grafting. Thirteen complications leading to early failures were recorded, resulting in an early failure rate of 0.7%. The regression analysis failed to identify statistically significant failure etiologies for the variables assessed. Conclusions: From this study it can be concluded that patients referred to a specialty clinic for implant placement were more likely to be partially edentulous and over 50 years old. Single-tooth replacement was the most frequent indication (> 50%). Similarly, additional bone augmentation was indicated in more than 50% of cases. Adhering to strict patient selection criteria and a standardized surgical protocol, an early failure rate of 0.7% was experienced in this study population

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cochlear implants have been of great benefit in restoring auditory function to individuals with profound bilateral sensorineural deafness. The implants are used to directly stimulate auditory nerves and send a signal to the brain that is then interpreted as sound. This project focuses on the development of a surgical positioning tool to accurately and effectively place an array of stimulating electrodes deep within the cochlea. This will lead to improved efficiency and performance of the stimulating electrodes, reduced surgical trauma to the cochlea, and as a result, improved overall performance to the implant recipient. The positioning tool reported here consists of multiple fluidic chambers providing localized curvature control along the length of the attached silicon electrode array. The chambers consist of 200μm inner diameter PET (polyethylene therephthalate) tubes with 4μm wall thickness. The chambers are molded in a tapered helical configuration to correspond to the cochlear shape upon relaxation of the actuators. This ensures that the optimal electrode placement within the cochlea is retained after the positioning tool becomes dormant (for chronic implants). Actuation is achieved by injecting fluid into the PET chambers and regulating the fluidic pressure. The chambers are arranged in a stacked, overlapping design to provide fluid connectivity with the non-implantable pressure controller and allow for local curvature control of the device. The stacked tube configuration allows for localized curvature control of various areas along the length of the electrode and additional stiffening and actuating power towards the base. Curvature is affected along the entire length of a chamber and the result is cumulative in sections of multiple chambers. The actuating chambers are bonded to the back of a silicon electrode array.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Meticulous sealing of opened air cells in the petrous bone is necessary for the prevention of cerebrospinal fluid (CSF) fistulae after vestibular schwannoma surgery. We performed a retrospective analysis to determine whether muscle or fat tissue is superior for this purpose. METHODS: Between January 2001 and December 2006, 420 patients underwent retrosigmoidal microsurgical removal by a standardized procedure. The opened air cells at the inner auditory canal and the mastoid bone were sealed with muscle in 283 patients and with fat tissue in 137 patients. Analysis was performed regarding the incidence of postoperative CSF fistulae and correlation with the patient's sex and tumor grade. RESULTS: The rate of postoperative CSF leak after application of fat tissue was lower (2.2%) than after use of muscle (5.7%). Women had less postoperative CSF leakage (3.4%) than men (5.6%). There was an inverse correlation with tumor grade. Patients with smaller tumors seemed to have a higher rate of CSF leakage than those with large tumors without hydrocephalus. Only large tumors with severe dislocation of the brainstem causing hydrocephalus showed a higher incidence of CSF leaks. CONCLUSION: Fat implantation is superior to muscle implantation for the prevention of CSF leakage after vestibular schwannoma surgery and should, therefore, be used for the sealing of opened air cells in cranial base surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Users of cochlear implant systems, that is, of auditory aids which stimulate the auditory nerve at the cochlea electrically, often complain about poor speech understanding in noisy environments. Despite the proven advantages of multimicrophone directional noise reduction systems for conventional hearing aids, only one major manufacturer has so far implemented such a system in a product, presumably because of the added power consumption and size. We present a physically small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. Supporting algorithms, which allow the adjustment of the opening angle and the maximum noise suppression, are proposed and evaluated. A portable real-time device for test in real acoustic environments is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Users of cochlear implants (auditory aids, which stimulate the auditory nerve electrically at the inner ear) often suffer from poor speech understanding in noise. We evaluate a small (intermicrophone distance 7 mm) and computationally inexpensive adaptive noise reduction system suitable for behind-the-ear cochlear implant speech processors. The system is evaluated in simulated and real, anechoic and reverberant environments. Results from simulations show improvements of 3.4 to 9.3 dB in signal to noise ratio for rooms with realistic reverberation and more than 18 dB under anechoic conditions. Speech understanding in noise is measured in 6 adult cochlear implant users in a reverberant room, showing average improvements of 7.9–9.6 dB, when compared to a single omnidirectional microphone or 1.3–5.6 dB, when compared to a simple directional two-microphone device. Subjective evaluation in a cafeteria at lunchtime shows a preference of the cochlear implant users for the evaluated device in terms of speech understanding and sound quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of implant-borne rehabilitations in residual alveolar ridges may be restricted by various anatomic conditions, as available bone height and characteristics. Here we report the clinical outcome of implants placed in severely resorbed posterior ridges, in addition to various implant-supported treatment modalities. Extra Oral implants (Straumann, Basel, Switzerland) with the intraosseous length of 2.5–5mm were installed in the posterior alveolar ridges. Following the healing period of 4–6 months, implants were exposed and included in the distal extensions of fixed and removable prosthesis. At recall appointments were collected surgical, clinical and radiological variables, including the evidence of adverse effects. An 8-years life table analysis was calculated. The treatment protocol was applied in thirty-five patients, presenting 31 removable and 4 fixed complete implant-supported dentures. A total of 61 Extra Oral implants were placed posterior to the distal implants, at the mean distance of 29.8mm (range 15.6–62.7mm). Three implants failed during the osteointegration phase, yielding an 8-year cumulative success rate of 92.24%. Following the osteointegration period, no major bone loss or other adverse events were found. The clinical results indicated that the Extra Oral implants may be successfully used in addition to the other, longer implants. Thus, a relatively long extension in the posterior region may be employed. With careful preoperative planning, this technique offers a simple and beneficial complementary treatment option for removable and fixed complete dentures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To analyze the survival and success rates of implants installed utilizing the (transalveolar) osteotome technique, to compare peri-implant soft tissue parameters and marginal bone levels of osteotome-installed implants with implants placed using standard surgical procedures, and to evaluate patient-centered outcomes. MATERIAL AND METHODS: During 2000 to 2005, 252 Straumann dental implants were inserted in 181 patients. The surgical technique was a modification of the original osteotome technique presented by Summers. In addition to the clinical examination, the patients were asked to give their perception of the surgical procedure, utilizing a visual analogue scale. RESULTS: The cumulative survival rate of the osteotome-installed implants after a mean follow-up time of 3.2 years, was 97.4% (95% confidence intervals: 94.4-98.8%). From the 252 implants inserted, three were lost before loading and another three were lost in the first and second year. According to residual bone height the survival was 91.3% for implant sites with < or =4 mm residual bone height, and 90% for sites with 4 mm and 5 mm, when compared with that of 100% in sites with bone height of above 5 mm. According to implant length the survival rates were 100% for 12 mm, 98.7% for 10 mm, 98.7% for 8 mm and only 47.6% for 6 mm implants. Soft tissue parameters (pocket probing depth, probing attachment level, bleeding on probing and marginal bone levels) did not yield any differences between the osteotome-installed and the conventionally placed implants. More than 90% of the patients were satisfied with the implant therapy and would undergo similar therapy again if necessary. The cost associated with implant therapy was considered to be justified. CONCLUSION: In conclusion, the osteotome technique was a reliable method for implant insertion in the posterior maxilla, especially at sites with 5 mm or more of preoperative residual bone height and a relatively flat sinus floor.