953 resultados para ecossistemas semi-lênticos


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A complete characterisation of PV modules for building integration is needed in order to know their influence on the building’s global energy balance. Specifically, certain characteristic parameters should be obtained for each different PV module suitable for building integrated photovoltaics (BIPV), some by direct or indirect measurements at the laboratory, and others by monitoring the element performance mounted in real operating conditions. In the case of transparent building envelopes it is particularly important to perform an optical and thermal characterization of the PV modules that would be integrated in them. This paper addresses the optical characterization of some commercial thin-film PV modules having different degrees of transparency, suitable for building integration in façades. The approach is based on the measurement of the spectral UV/Vis/NIR reflectance and transmittance of the different considered samples, both at normal incidence and as a function of the angle of incidence. With the obtained results, the total and zoned UV, visible and NIR transmission and reflection values are calculated, enabling the correct characterization of the PV modules integrated in façades and the subsequent evaluation of their impact over the electrical, thermal and lighting performance in a building.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a methodology for the integral energy performance characterization (thermal, daylighting and electrical behavior) of semi-transparent photovoltaic modules (STPV) under real operation conditions is presented. An outdoor testing facility to analyze simultaneously thermal, luminous and electrical performance of the devices has been designed, constructed and validated. The system, composed of three independent measurement subsystems, has been operated in Madrid with four prototypes of a-Si STPV modules, each one corresponding to a specific degree of transparency. The extensive experimental campaign, continued for a whole year rotating the modules under test, has validated the reliability of the testing facility under varying environmental conditions. The thermal analyses show that both the solar protection and insulating properties of the laminated prototypes are lower than those achieved by a reference glazing whose characteristics are in accordance with the Spanish Technical Building Code. Daylighting analysis shows that STPV elements have an important lighting energy saving potential that could be exploited through their integration with strategies focused to reduce illuminance values in sunny conditions. Finally, the electrical tests show that the degree of transparency is not the most determining factor that affects the conversion efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: A recently introduced pragmatic scheme promises to be a useful catalog of interneuron names.We sought to automatically classify digitally reconstructed interneuronal morphologies according tothis scheme. Simultaneously, we sought to discover possible subtypes of these types that might emergeduring automatic classification (clustering). We also investigated which morphometric properties weremost relevant for this classification.Materials and methods: A set of 118 digitally reconstructed interneuronal morphologies classified into thecommon basket (CB), horse-tail (HT), large basket (LB), and Martinotti (MA) interneuron types by 42 of theworld?s leading neuroscientists, quantified by five simple morphometric properties of the axon and fourof the dendrites. We labeled each neuron with the type most commonly assigned to it by the experts. Wethen removed this class information for each type separately, and applied semi-supervised clustering tothose cells (keeping the others? cluster membership fixed), to assess separation from other types and lookfor the formation of new groups (subtypes). We performed this same experiment unlabeling the cells oftwo types at a time, and of half the cells of a single type at a time. The clustering model is a finite mixtureof Gaussians which we adapted for the estimation of local (per-cluster) feature relevance. We performedthe described experiments on three different subsets of the data, formed according to how many expertsagreed on type membership: at least 18 experts (the full data set), at least 21 (73 neurons), and at least26 (47 neurons).Results: Interneurons with more reliable type labels were classified more accurately. We classified HTcells with 100% accuracy, MA cells with 73% accuracy, and CB and LB cells with 56% and 58% accuracy,respectively. We identified three subtypes of the MA type, one subtype of CB and LB types each, andno subtypes of HT (it was a single, homogeneous type). We got maximum (adapted) Silhouette widthand ARI values of 1, 0.83, 0.79, and 0.42, when unlabeling the HT, CB, LB, and MA types, respectively,confirming the quality of the formed cluster solutions. The subtypes identified when unlabeling a singletype also emerged when unlabeling two types at a time, confirming their validity. Axonal morphometricproperties were more relevant that dendritic ones, with the axonal polar histogram length in the [pi, 2pi) angle interval being particularly useful.Conclusions: The applied semi-supervised clustering method can accurately discriminate among CB, HT, LB, and MA interneuron types while discovering potential subtypes, and is therefore useful for neuronal classification. The discovery of potential subtypes suggests that some of these types are more heteroge-neous that previously thought. Finally, axonal variables seem to be more relevant than dendritic ones fordistinguishing among the CB, HT, LB, and MA interneuron types.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within the building energy saving strategies, BIPV (building integrated photovoltaic systems) present a promising potential based on the close relationship existing between these multifunctional systems and the overall building energy balance. Building integration of STPV (semi-transparent photovoltaic) elements affects deeply the building energy demand since it influences the heating, cooling and lighting loads as well as the local electricity generation. This work analyses over different window-to-wall ratios the overall energy performance of five STPV elements, each element having a specific degree of transparency, in order to assess the energy saving potential compared to a conventional solar control glass compliant with the local technical standard. The prior optical characterization, focused to measure the spectral properties of the elements, was experimentally undertaken. The obtained data were used to perform simulations based on a reference office building using a package of specific software tools (DesignBuilder, EnergyPlus, PVsyst, and COMFEN) to take proper account of the STPV peculiarities. To evaluate the global energy performance of the STPV elements a new Energy Balance Index was formulated. The results show that for intermediate and large façade openings the energy saving potential provided by the STPV solutions ranges between 18% and 59% compared to the reference glass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly(L‐lactide) is a widely studied biomaterial, currently approved for use in a range of medical devices. Its mechanical properties can be tailored giving the material different crystallinity degrees. PLLA presents a complex non‐linear behaviour that depends not only on structural parameters such as crystallinity degree but also on external parameters such as strain rate and temperature. Failure of polymeric implants is attributed to their intrinsic time‐dependent performance under static loading conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La hipótesis general que esta tesis quiere demostrar es que la integración arquitectónica de sistemas fotovoltaicos semitransparentes (STPV) puede contribuir a mejorar la eficiencia energética de los edificios. Por lo tanto, la investigación se centra en el desarrollo de una metodología capaz de cuantificar la reducción de la demanda energética del edificio proporcionada por estas novedosas soluciones constructivas. Al mismo tiempo, los parámetros de diseño de las soluciones STPV se han analizado para establecer cuales presentan el mayor impacto sobre el balance energético global del edificio y por lo tanto tienen que ser cuidadosamente definidos a la hora de optimizar el comportamiento energético del mismo. A la luz de estos objetivos, la metodología de estudio se ha centrado en tres puntos principales:  Caracterizar el comportamiento energético global de sistemas STPV en condiciones de operación realistas, similares a las que se darían en un sistema real;  Caracterizar el comportamiento energético global de sistemas STPV en condiciones controladas, con el objetivo de estudiar la variación del comportamiento del los elementos en función de parámetro de diseño y operación;  Evaluar el potencial de ahorro energético global de los sistemas STPV en comparación con soluciones acristaladas convencionales al variar de las condiciones de contorno constituidas por los parámetros de diseño (como el grado de transparencia), las características arquitectónicas (como el ratio entre superficie acristalada y superficie opaca en la fachada del edificio) y las condiciones climáticas (cubriendo en particular la climatología europea). En síntesis, este trabajo intenta contribuir a comprender la interacción que existe entre los sistemas STPV y el edificio, proporcionando tanto a los fabricantes de los componentes como a los profesionales de la construcción información valiosa sobre el potencial de ahorro energético asociado a estos nuevos sistemas constructivos. Asimismo el estudio define los parámetros de diseño adecuados para lograr soluciones eficientes tanto en proyectos nuevos como de rehabilitación. ABSTRACT The general hypothesis this work seeks to demonstrate is that the architectural integration of Semi-Transparent Photovoltaic (STPV) systems can contribute to improving the energy efficiency of buildings. Accordingly, the research has focused on developing a methodology able to quantify the building energy demand reduction provided by these novel constructive solutions. At the same time, the design parameters of the STPV solution have been analysed to establish which of them have the greatest impact on the global energy balance of the building, and therefore which have to be carefully defined in order to optimize the building operation. In the light of these goals, the study methodology has focused on three main points:  To characterise the global energy behaviour of STPV systems in realistic operating conditions, similar to those in which a real system will operate;  To characterise the global energy behaviour of STPV systems in controlled conditions in order to study how the performance varies depending on the design and operating parameters;  To assess the global energy saving potential of STPV systems in comparison with conventional glazing solutions by varying the boundary conditions, including design parameters (such as the degree of transparency), architectural characteristics (such as the Window to Wall Ratio) and climatic conditions (covering the European climatic conditions). In summary, this work has sought to contribute to the understanding of the interaction between STPV systems and the building, providing both components manufacturers and construction technicians, valuable information on the energy savings potential of these new construction systems and defining the appropriate design parameters to achieve efficient solutions in both new and retrofitting projects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports extensive tests of empirical equations developed by different authors for harbour breakwater overtopping. First, the existing equations are compiled and evaluated as tools for estimating the overtopping rates on sloping and vertical breakwaters. These equations are then tested using the data obtained in a number of laboratory studies performed in the Centre for Harbours and Coastal Studies of the CEDEX, Spain. It was found that the recommended application ranges of the empirical equations typically deviate from those revealed in the experimental tests. In addition, a neural network model developed within the European CLASH Project is tested. The wind effects on overtopping are also assessed using a reduced scale physical model

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electric probes are objects immersed in the plasma with sharp boundaries which collect of emit charged particles. Consequently, the nearby plasma evolves under abrupt imposed and/or naturally emerging conditions. There could be localized currents, different time scales for plasma species evolution, charge separation and absorbing-emitting walls. The traditional numerical schemes based on differences often transform these disparate boundary conditions into computational singularities. This is the case of models using advection-diffusion differential equations with source-sink terms (also called Fokker-Planck equations). These equations are used in both, fluid and kinetic descriptions, to obtain the distribution functions or the density for each plasma species close to the boundaries. We present a resolution method grounded on an integral advancing scheme by using approximate Green's functions, also called short-time propagators. All the integrals, as a path integration process, are numerically calculated, what states a robust grid-free computational integral method, which is unconditionally stable for any time step. Hence, the sharp boundary conditions, as the current emission from a wall, can be treated during the short-time regime providing solutions that works as if they were known for each time step analytically. The form of the propagator (typically a multivariate Gaussian) is not unique and it can be adjusted during the advancing scheme to preserve the conserved quantities of the problem. The effects of the electric or magnetic fields can be incorporated into the iterative algorithm. The method allows smooth transitions of the evolving solutions even when abrupt discontinuities are present. In this work it is proposed a procedure to incorporate, for the very first time, the boundary conditions in the numerical integral scheme. This numerical scheme is applied to model the plasma bulk interaction with a charge-emitting electrode, dealing with fluid diffusion equations combined with Poisson equation self-consistently. It has been checked the stability of this computational method under any number of iterations, even for advancing in time electrons and ions having different time scales. This work establishes the basis to deal in future work with problems related to plasma thrusters or emissive probes in electromagnetic fields.