989 resultados para air-sealed test
Resumo:
The high-speed combustible gas ignited by a hot gas jet, which is induced by shock focusing, was experimentally investigated. By use of the separation mode of shock tube, the test section of a single shock tube is split into two parts, which provide the high-speed flow of combustible gas and pilot flame of hot gas jet, respectively. In the interface of two parts of test sections the flame of jet was formed and spread to the high-speed combustible gas. Two kinds of the ignitions, 3-D "line-flame ignition" and 2-D "plane-flame ignition", were investigated. In the condition of 3-D "line-flame ignition" of combustion, thicker hot gas jet than pure air jet, was observed in schlieren photos. In the condition of 2-D "plane-flame ignition" of combustion, the delay time of ignition and the angle of flame front in schlieren photos were measured, from which the velocity of flame propagation in the high-speed combustible gas is estimated in the range of 30-90m/s and the delay time of ignition is estimated in the range of 0.12-0.29ms.
Resumo:
Modeling results are presented concerning the characteristicsoflaminar and turbulentargonplasmajetsimpingingnormally upon a flat plate (workpiece) in ambient air. It is found that the presence of the flat plate significantly enhances the entrainment rate of ambient air into the jets and affects on the flow and temperature fields in the near-plate region of the jets. At comparatively large distances between the plate and the jet inlet, the axial gradients of the plasma parameters in the laminarplasmaimpinging-jets assume values much less than those in the turbulentplasmaimpinging-jets.
Resumo:
With the laminar plasma materials processing as the research background, modeling study is conducted concerning the effects of argon shroud on the characteristics of the laminar argon plasma jet impinging normally upon a flat substrate located in air surroundings. It is shown that adding shrouding gas is an effective method to reduce and control the entrainment of ambient air into the laminar plasma jet. The shrouding gas flow rate or velocity, the injection slot width and the stand-off distance of the substrate appreciably affect the air contents in the plasma near the substrate surface.
Resumo:
The Accelerating Moment Release (AMR) preceding earthquakes with magnitude above 5 in Australia that occurred during the last 20 years was analyzed to test the Critical Point Hypothesis. Twelve earthquakes in the catalog were chosen based on a criterion for the number of nearby events. Results show that seven sequences with numerous events recorded leading up to the main earthquake exhibited accelerating moment release. Two occurred near in time and space to other earthquakes preceded by AM R. The remaining three sequences had very few events in the catalog so the lack of AMR detected in the analysis may be related to catalog incompleteness. Spatio-temporal scanning of AMR parameters shows that 80% of the areas in which AMR occurred experienced large events. In areas of similar background seismicity with no large events, 10 out of 12 cases exhibit no AMR, and two others are false alarms where AMR was observed but no large event followed. The relationship between AMR and Load-Unload Response Ratio (LURR) was studied. Both methods predict similar critical region sizes, however, the critical point time using AMR is slightly earlier than the time of the critical point LURR anomaly.
Resumo:
The performance of a small high-speed liquid jet apparatus is described. Water jets of 200m/s to 700m/s have been obtained by firing a deformable lead slug from an air rifle into a stainless steel nozzle containing water sealed with a rubber diaphragm. Nozzle devices of using the impact extrusion (IE) method and cumulation (CU) method are designed to generate jets. The injection sequences are visualized using schlieren photography. The difference between the IE and CU methods in the jet generation is found.
Resumo:
The effects of the free-stream thermo-chemical state on the test model flow field in the high-enthalpy tunnel are studied numerically. The properties of the free-stream, which is in thermo-chemical non-equilibrium, are determined by calculating the nozzle flow field. A free-stream with total enthalpy equal to the real one in the tunnel while in thermo-chemical equilibrium is constructed artificially to simulate the natural atmosphere condition. The flow fields over the test models (blunt cone and Apollo command capsule model) under both the non-equilibrium and the virtual equilibrium free-stream conditions are calculated. By comparing the properties including pressure, temperature, species concentration and radiation distributions of these two types of flow fields, the effects of the non-equilibrium state of the free-stream in the high-enthalpy shock tunnel are analyzed.
Resumo:
Test
Resumo:
A set of downloadable resources containing information on course structures