956 resultados para Windows:2023
Resumo:
Different shapes of asymmetric awnings for east and west windows are investigated mathematically as well as by measurement in a model. A box with 90 cm side and a 30x30 cm window was placed outdoor in overcast weather and the daylight factor was measured at the bottom of the box when the window was unshaded or equipped with different awnings. The average daylight factor in the box decreased from 4.6% for the unshaded window to 1.0% when a full awning was used. With “the best” asymmetrical awning, the average daylight factor was 80% larger than with the full awing. Using Dutch climate, calculation of the energy from direct radiation transmitted through the window during the cooling season showed that this was decreased from 100% as an annual mean for the unshaded window down 22% with a full awing. With “the best” asymmetrical awning, 26% of the energy was transmitted. Calculation of the indoor temperature in a hypothetical row house in Netherlands show that the use of either normal or asymmetrical awnings considerable decrease the indoor temperature during the hot season. Therefore the use of asymmetrical awnings for east or west faced windows considerable can increase the daylight in buildings, with almost no change in overheating, compared to if traditional awnings are used.
Resumo:
Cloud computing innebär användning av datorresurser som är tillgängliga via ett nätverk, oftast Internet och är ett område som har vuxit fram i snabb takt under de senaste åren. Allt fler företag migrerar hela eller delar av sin verksamhet till molnet. Sogeti i Borlänge har behov av att migrera sina utvecklingsmiljöer till en molntjänst då drift och underhåll av dessa är kostsamma och tidsödande. Som Microsoftpartners vill Sogeti använda Microsoft tjänst för cloud computing, Windows Azure, för detta syfte. Migration till molnet är ett nytt område för Sogeti och de har inga beskrivningar för hur en sådan process går till. Vårt uppdrag var att utveckla ett tillvägagångssätt för migration av en IT-lösning till molnet. En del av uppdraget blev då att kartlägga cloud computing, dess beståndsdelar samt vilka för- och nackdelar som finns, vilket har gjort att vi har fått grundläggande kunskap i ämnet. För att utveckla ett tillvägagångssätt för migration har vi utfört flera migrationer av virtuella maskiner till Windows Azure och utifrån dessa migrationer, litteraturstudier och intervjuer dragit slutsatser som mynnat ut i ett generellt tillvägagångssätt för migration till molnet. Resultatet har visat att det är svårt att göra en generell men samtidigt detaljerad beskrivning över ett tillvägagångssätt för migration, då scenariot ser olika ut beroende på vad som ska migreras och vilken typ av molntjänst som används. Vi har dock utifrån våra erfarenheter från våra migrationer, tillsammans med litteraturstudier, dokumentstudier och intervjuer lyft vår kunskap till en generell nivå. Från denna kunskap har vi sammanställt ett generellt tillvägagångssätt med större fokus på de förberedande aktiviteter som en organisation bör genomföra innan migration. Våra studier har även resulterat i en fördjupad beskrivning av cloud computing. I vår studie har vi inte sett att någon tidigare har beskrivit kritiska framgångsfaktorer i samband med cloud computing. I vårt empiriska arbete har vi dock identifierat tre kritiska framgångsfaktorer för cloud computing och i och med detta täckt upp en del av kunskapsgapet där emellan.
Resumo:
This research was carried out by studying possible renovation of a two-storey detached multifamily building by using passive solar design options in a cold climate in Borlänge, Sweden where the heating Degree Days are 4451 (base 20°C). Borlänge`s housing company, Tunabyggen, plans to renovate the project house located inthe multicultural district, Jakobsgårdarna. The goal of the thesis was to suggest a redesign of the current building, decrease the heating energy use, by applying passive solar design and control strategies, in a most reasonable way. In addition ensure a better thermal comfort for the tenants in the dwellings. Literatures have been studied, from which can be inferred that passive design should be abasic design consideration for all housing constructions, because it has advantages to ensure thermal comfort, and reduce the energy use. In addition further savings can be achieved applying different types of control strategies, from which the house will be more personalized, and better adapted to the user’s needs.The proposed method is based on simulations by using TRNSYS software. First a proper building model was set up, which represents the current state of the project building. Then the thermal insulation and the windows were upgraded, based on today's building regulations. The developments of the passive solar options were accomplished in two steps. First of all the relevant basic passive design elements were considered, then those advantages were compared to the advantages of applying new conventional thermostat, and shading control strategies.The results show that there is significant potential with the different types of passive solar design; their usage depends primarily on the location of the site as well as the orientation of the project building. Applying the control strategies, such as thermostat, and shading control, along the thermal insulation upgrade, may lead to significant energy savings (around 40 %), by comparison to the reference building without any upgrade.
Resumo:
In this project, Stora Enso’s newly developed building system has been further developed to allow building to the Swedish passive house standard for the Swedish climate. The building system is based on a building framework of CLT (Cross laminated timber) boards. The concept has been tested on a small test building. The experience gained from this test building has also been used for planning a larger building (two storeys with the option of a third storey) with passive house standard with this building system. The main conclusions from the project are: It is possible to build airtight buildings with this technique without using traditional vapour barriers. Initial measurements show that this can be done without reaching critical humidity levels in the walls and roof, at least where wood fibre insulation is used, as this has a greater capacity for storing and evening out the moisture than mineral wool. However, the test building has so far not been exposed to internal generation of moisture (added moisture from showers, food preparation etc.). This needs to be investigated and this will be done during the winter 2013-14. A new fixing method for doors and windows has been tested without traditional fibre filling between them and the CLT panel. The door or window is pressed directly on to the CLT panel instead, with an expandable sealing strip between them. This has been proved to be successful. The air tightness between the CLT panels is achieved with expandable sealing strips between the panels. The position of the sealing strips is important, both for the air tightness itself and to allow rational assembly. Recurrent air tightness measurements show that the air tightness decreased somewhat during the first six months, but not to such an extent that the passive house criteria were not fulfilled. The reason for the decreased air tightness is not clear, but can be due to small movements in the CLT construction and also to the sealing strips being affected by changing outdoor temperatures. Long term measurements (at least two years) have to be carried out before more reliable conclusions can be drawn regarding the long term effect of the construction on air tightness and humidity in the walls. An economic analysis comparing using a concrete frame or the studied CLT frame for a three storey building shows that it is probably more expensive to build with CLT. For buildings higher than three floors, the CLT frame has economic advantages, mainly because of the shorter building time compared to using concrete for the frame. In this analysis, no considerations have been taken to differences in the influence on the environment or the global climate between the two construction methods.
Resumo:
Allt hårdare lagkrav gör att det är svårt att energieffektivisera befintliga byggnader utan att förändra deras utseende. Syftet med examensarbetet är att utreda hur stor energieffektivisering, för tre befintliga småhus uppförda under 1900-talet, som är möjlig att uppnå genom förbättring av byggnadernas klimatskal, det vill säga tak, väggar, golv, fönster och dörrar, utan att förvanska byggnadernas utseende och samtidigt bevara deras kulturhistoriska värden. Arbetet bestod av en förstudie där tre byggnader identifierades, ett undersökningsskede där information om byggnaderna togs fram och ett slutsatsskede där energibesparande åtgärdsförslag togs fram och utvärderades. Byggnader som var goda representanter för sin tid och stil söktes. Byggnader från 1910-talet, 1930-talet och 1970-talet, lokaliserades. Sedan gjordes det fallstudier med intervjuer och inventeringar. För att utreda byggnadens klimatskal utfördes u-värdesberäkningar och energiberäkningar av befintliga byggander och byggnader baserade på föreslagna åtgärdsförslag. Ingen av byggnaderna nådde efter föreslagna åtgärder ner till passivhuskravet 59 kWh/år/m2 Atemp eller BBR-kravet 110 kWh/år/m2 Atemp för en byggnads specifika energianvändning. Den största möjliga energieffektivisering för de tre byggnaderna uppförda under 1900-talet, som är möjlig att uppnå utan att förvanska byggnadernas utseende och samtidigt bevara deras kulturhistoriska värden är 13,0 kWh/år/m2 Atemp, 49,7 kWh/år/m2 Atemp respektive 64,8 kWh/år/m2 Atemp. Slutsatser från arbetet är att byggnader från 1910-tal kan åtgärdas genom att isolera fönstren, sätta dit en extra dörr på insidan av ytterdörren samt tilläggsisolera snedtaket. Byggnader från 1930-tal kan åtgärdas genom att isolera fönstren med en isolerruta på insidan av fönstret och dörrarna med en extra dörr på insidan av ytterdörren. Byggnader från 1970-tal kan åtgärda fönstren genom att byta ut dem till energifönster, ingen åtgärd för golvet men fasaden isoleras utvändigt med vakuumisolering. Byggnaden från 1970-talet klarade sig bäst i jämförelsen eftersom den var i autentiskt skick från början vilket gjorde att förbättringen blev större än för till exempel byggnaden från 1910-talet som redan var ombyggd innan åtgärder föreslogs.
Resumo:
Att kunna gör en effektiv undersökning av det flyktiga minnet är något som blir viktigare ochviktigare i IT-forensiska utredningar. Dels under Linux och Windows baserade PC installationermen också för mobila enheter i form av Android och enheter baserade andra mobila opperativsy-stem.Android använder sig av en modifierad Linux-kärna var modifikationer är för att anpassa kärnantill de speciella krav som gäller för ett mobilt operativsystem. Dessa modifikationer innefattardels meddelandehantering mellan processer men även ändringar till hur internminnet hanteras ochövervakas.Då dessa två kärnor är så pass nära besläktade kan samma grundläggande principer användas föratt dumpa och undersöka minne. Dumpningen sker via en kärn-modul vilket i den här rapportenutgörs av en programvara vid namn LiME vilken kan hantera bägge kärnorna.Analys av minnet kräver att verktygen som används har en förståelse för minneslayouten i fråga.Beroende på vilken metod verktyget använder så kan det även behövas information om olika sym-boler. Verktyget som används i det här examensarbetet heter Volatility och klarar på papperet avatt extrahera all den information som behövs för att kunna göra en korrekt undersökning.Arbetet avsåg att vidareutveckla existerande metoder för analys av det flyktiga minnet på Linux-baserade maskiner (PC) och inbyggda system(Android). Problem uppstod då undersökning avflyktigt minne på Android och satta mål kunde inte uppnås fullt ut. Det visade sig att minnesanalysriktat emot PC-plattformen är både enklare och smidigare än vad det är mot Android.
Resumo:
The specification of Quality of Service (QoS) constraints over software design requires measures that ensure such requirements are met by the delivered product. Achieving this goal is non-trivial, as it involves, at least, identifying how QoS constraint specifications should be checked at the runtime. In this paper we present an implementation of a Model Driven Architecture (MDA) based framework for the runtime monitoring of QoS properties. We incorporate the UML2 superstructure and the UML profile for Quality of Service to provide abstract descriptions of component-and-connector systems. We then define transformations that refine the UML2 models to conform with the Distributed Management Taskforce (DMTF) Common Information Model (CIM) (Distributed Management Task Force Inc. 2006), a schema standard for management and instrumentation of hardware and software. Finally, we provide a mapping the CIM metamodel to a .NET-based metamodel for implementation of the monitoring infrastructure utilising various .NET features including the Windows Management Instrumentation (WMI) interface.