950 resultados para Whitman, Walt, 1819-1892.
Resumo:
A theoretical model for Dicke superradiance (SR) in diode lasers is proposed using the travelling wave method with a spatially resolved absorber and spectrally resolved gain. The role of electrode configuration and optical bandwidth are compared and contrasted as a route to enhance femtosecond pulse power. While pulse duration can be significantly reduced through careful absorber length specification, stability is degraded. However an increased spectral gain bandwidth of up to 150 nm is predicted to allow pulsewidth reductions of down to 10 fs and over 500-W peak power without further degradation in pulse stability. © 2011 IEEE.
Resumo:
The last few years have seen considerable progress in pedestrian detection. Recent work has established a combination of oriented gradients and optic flow as effective features although the detection rates are still unsatisfactory for practical use. This paper introduces a new type of motion feature, the co-occurrence flow (CoF). The advance is to capture relative movements of different parts of the entire body, unlike existing motion features which extract internal motion in a local fashion. Through evaluations on the TUD-Brussels pedestrian dataset, we show that our motion feature based on co-occurrence flow contributes to boost the performance of existing methods. © 2011 IEEE.
Resumo:
白鳍豚与长江江豚不仅属于长江,也不仅属于中国,白鳍豚与长江江豚更属于世界,属于大自然。只有全世界人民共同携手,保护长江,保护我们赖以生存的大江大河,保护我们的共同家园———地球,白鳍豚与长江江豚才会永驻江河,与人类一道共同走向未来。
Resumo:
The design and fabrication of a novel 2-scale topography dry electrode using macro and micro needles is presented. The macro needles enable biopotential measurements on hairy skin, the function of the micro needles is to decrease the electrode impedance even further by penetrating the outer skin layer. Also, a fast and reliable impedance characterization protocol is described. Based on this impedance measurement protocol, a comparison study is made between our dry electrode, 3 other commercial dry electrodes and a standard wet gel electrode. Promising results are already obtained with our electrodes which do not have skin piercing micro needles. For the proposed electrodes, three different conductive coatings (Ag/AgCl/Au) are compared. AgCl is found to be slightly better than Ag as coating material, while our Au coated electrodes have the highest impedance.