997 resultados para VISUAL TRANSMISSION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ignoring irrelevant visual information aids efficient interaction with task environments. We studied how people, after practice, start to ignore the irrelevant aspects of stimuli. For this we focused on how information reduction transfers to rarely practised and novel stimuli. In Experiment 1, we compared competing mathematical models on how people cease to fixate on irrelevant parts of stimuli. Information reduction occurred at the same rate for frequent, infrequent, and novel stimuli. Once acquired with some stimuli, it was applied to all. In Experiment 2, simplification of task processing also occurred in a once-for-all manner when spatial regularities were ruled out so that people could not rely on learning which screen position is irrelevant. Apparently, changes in eye movements were an effect of a once-for-all strategy change rather than a cause of it. Overall, the results suggest that participants incidentally acquired knowledge about regularities in the task material and then decided to voluntarily apply it for efficient task processing. Such decisions should be incorporated into accounts of information reduction and other theories of strategy change in skill acquisition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multisensory memory traces established via single-trial exposures can impact subsequent visual object recognition. This impact appears to depend on the meaningfulness of the initial multisensory pairing, implying that multisensory exposures establish distinct object representations that are accessible during later unisensory processing. Multisensory contexts may be particularly effective in influencing auditory discrimination, given the purportedly inferior recognition memory in this sensory modality. The possibility of this generalization and the equivalence of effects when memory discrimination was being performed in the visual vs. auditory modality were at the focus of this study. First, we demonstrate that visual object discrimination is affected by the context of prior multisensory encounters, replicating and extending previous findings by controlling for the probability of multisensory contexts during initial as well as repeated object presentations. Second, we provide the first evidence that single-trial multisensory memories impact subsequent auditory object discrimination. Auditory object discrimination was enhanced when initial presentations entailed semantically congruent multisensory pairs and was impaired after semantically incongruent multisensory encounters, compared to sounds that had been encountered only in a unisensory manner. Third, the impact of single-trial multisensory memories upon unisensory object discrimination was greater when the task was performed in the auditory vs. visual modality. Fourth, there was no evidence for correlation between effects of past multisensory experiences on visual and auditory processing, suggestive of largely independent object processing mechanisms between modalities. We discuss these findings in terms of the conceptual short term memory (CSTM) model and predictive coding. Our results suggest differential recruitment and modulation of conceptual memory networks according to the sensory task at hand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Self-nanoemulsifying drug delivery systems of gemfibrozil were developed under Quality by Design approach for improvement of dissolution and oral absorption. Preliminary screening was performed to select proper components combination. BoxBehnken experimental design was employed as statistical tool to optimize the formulation variables, X1 (Cremophor® EL), X2 (Capmul® MCM-C8), and X3 (lemon essential oil). Systems were assessed for visual characteristics (emulsification efficacy), turbidity, droplet size, polydispersity index and drug release. Different pH media were also assayed for optimization. Following optimization, the values of formulation components (X1, X2, and X3) were 32.43%, 29.73% and 21.62%, respectively (16.22% of gemfibrozil). Transmission electron microscopy demonstrated spherical droplet morphology. SNEEDS release study was compared to commercial tablets. Optimized SNEDDS formulation of gemfibrozil showed a significant increase in dissolution rate compared to conventional tablets. Both formulations followed Weibull mathematical model release with a significant difference in td parameter in favor of the SNEDDS. Equally amodelistic parameters were calculated being the dissolution efficiency significantly higher for SNEDDS, confirming that the developed SNEDDS formulation was superior to commercial formulation with respect to in vitro dissolution profile. This paper provides an overview of the SNEDDS of the gemfibrozil as a promising alternative to improve oral absorption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The globalization and development of an information society promptly change shape of the modern world. Cities and especially megacities including Saint-Petersburg are in the center of occuring changes. As a result of these changes the economic activities connected to reception and processing of the information now play very important role in economy of megacities what allows to characterize them as "information". Despite of wide experience in decision of information questions Russia, and in particular Saint-Petersburg, lag behind in development of information systems from the advanced European countries. The given master's thesis is devoted to development of an information system (data transmission network) on the basis of wireless technology in territory of Saint-Petersburg region within the framework of FTOP "Electronic Russia" and RTOP "Electronic Saint-Petersburg" programs. Logically the master's thesis can be divided into 3 parts: 1. The problems, purposes, expected results, terms and implementation of the "Electronic Russia" program. 2. Discussion about wireless data transmission networks (description of technology, substantiation of choice, description of signal's transmission techniques and types of network topology). 3. Fulfillment of the network (organization of central network node, regional centers, access lines, description of used equipment, network's capabilities), financial provision of the project, possible network management models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to improve the efficacy and safety of treatments, drug dosage needs to be adjusted to the actual needs of each patient in a truly personalized medicine approach. Key for widespread dosage adjustment is the availability of point-of-care devices able to measure plasma drug concentration in a simple, automated, and cost-effective fashion. In the present work, we introduce and test a portable, palm-sized transmission-localized surface plasmon resonance (T-LSPR) setup, comprised of off-the-shelf components and coupled with DNA-based aptamers specific to the antibiotic tobramycin (467 Da). The core of the T-LSPR setup are aptamer-functionalized gold nanoislands (NIs) deposited on a glass slide covered with fluorine-doped tin oxide (FTO), which acts as a biosensor. The gold NIs exhibit localized plasmon resonance in the visible range matching the sensitivity of the complementary metal oxide semiconductor (CMOS) image sensor employed as a light detector. The combination of gold NIs on the FTO substrate, causing NIs size and pattern irregularity, might reduce the overall sensitivity but confers extremely high stability in high-ionic solutions, allowing it to withstand numerous regeneration cycles without sensing losses. With this rather simple T-LSPR setup, we show real-time label-free detection of tobramycin in buffer, measuring concentrations down to 0.5 μM. We determined an affinity constant of the aptamer-tobramycin pair consistent with the value obtained using a commercial propagating-wave based SPR. Moreover, our label-free system can detect tobramycin in filtered undiluted blood serum, measuring concentrations down to 10 μM with a theoretical detection limit of 3.4 μM. While the association signal of tobramycin onto the aptamer is masked by the serum injection, the quantification of the captured tobramycin is possible during the dissociation phase and leads to a linear calibration curve for the concentrations over the tested range (10-80 μM). The plasmon shift following surface binding is calculated in terms of both plasmon peak location and hue, with the latter allowing faster data elaboration and real-time display of the results. The presented T-LSPR system shows for the first time label-free direct detection and quantification of a small molecule in the complex matrix of filtered undiluted blood serum. Its uncomplicated construction and compact size, together with the remarkable performances, represent a leap forward toward effective point-of-care devices for therapeutic drug concentration monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Prominent visual symptoms can present in the visual variant of Alzheimer's disease (VVAD). Ophthalmologists have a significant role to play in the early diagnosis of VVAD. METHODS: We retrospectively reviewed the files of ten consecutive patients diagnosed with VVAD. All patients had a full neuro-ophthalmologic examination, a formal neurological and neuro-psychological testing, and cerebral MRI to confirm diagnosis. In addition, functional neuroimaging was obtained in seven patients. RESULTS: The common primary symptom at presentation with all patients was difficulty with near vision (reading difficulty n = 8, "visual blur" in near vision n = 2), and difficulty writing (n = 3). Following assessment, impaired reading and writing skills were evident in 9/10 and 8/10 patients respectively. Median distance visual acuity was 20/25 and at near the median visual acuity was J6. Partial homonymous visual field defect was detected in 80 % (8/10) of the patients. Color vision was impaired in all patients when tested with Ishihara pseudoisochromatic plates, but simple color naming was normal in 8/9 tested patients. Simultanagnosia was present in 8/10 patients. Vision dysfunction corresponded with cerebral MRI findings where parieto-occipital cortical atrophy was observed in all patients. PET scan (5 patients) or SPECT (2 patients) revealed parieto-occipital dysfunction (hypometabolism or hypoperfusion) in all 7 tested patients CONCLUSIONS: Visual difficulties are prominent in VVAD. Dyslexia, incomplete homonymous hemianopia, preserved color identification with abnormal color vision on Ishihara, and simultanagnosia were all symptoms observed frequently in this patient series. Ophthalmologists should be aware of the possibility of neurodegenerative disorders such as VVAD in patients with unexplained visual complaints, in particular reading difficulties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High barrier materiaaleilla pyritään pidentämään pakattujen elintarvikkeiden hyllyikää. Barrierin tärkein tehtävä on elintarvikkeen suojaaminen hapelta ja kosteudelta. Alumiinin käyttöä barriermateriaalina pyritään vähentämään korvaamalla alumiini polymeereillä, jotka täyttävät elintarvikkeiden asettamat korkeat säilyvyysvaatimukset. Etyylivinyylialkoholin (EVOH) hapenläpäisevyys on kuivissa olosuhteissa alhaisin kaupallisista muovilaaduista. EVOH tarjoaa myös erinomaisen suojan muita kaasuja, rasvoja, hajuja ja aromeja vastaan ja sitä on helppo prosessoida. Polyamideilla on erinomainen kaasutiiveys sekä hyvä lujuus ja sitkeys. Eri muovilaatuja sekoittamalla voidaan vähentää hapenläpäisyä ja parantaa prosessointia. Polyolefiineja käytetään yleisesti päällystysmateriaaleina, koska ne suojaavat tuotetta erinomaisesti kosteudelta. Hapenläpäisyllä tarkoitetaan hapen kulkeutumista materiaalin läpi joko permeaation kautta tai reikien ja vuotojen läpi. Kaasun permeoitumiseen materiaalin läpi vaikuttavat materiaalin vapaa tilavuus, kiteisyysaste, orientaatio, substituointi, suhteellinen kosteus, lämpötila, barrierkerroksen paksuus, paine-ero ja permeoituvan molekyylin ominaisuudet. Kokeellisessa osassa analysoitiin ja vertailtiin kartonkipohjaisia mehutölkkejä, joissa käytettävät high barrier materiaalit olivat EVOH ja PA. Kartonkipohjaisia alumiinitölkkejä käytettiin referenssinä. Pakkausten hapenläpäisevyysmittauksissa saatiin samasta näytteestä toistettavia tuloksia, vaikka vuotomittauksissa saadut tulokset eivät olleet vertailukelpoisia hapenläpäisytulosten kanssa. Tölkkien valmistus vaikutti oleellisesti pakkausten tiiveysominaisuuksiin. Hapenläpäisy vuotojen ja reikien läpi oli merkittävämpää kuin hapenläpäisy materiaalin läpi. Pakkausten tiiveysominaisuuksia analysoitiin mittaamalla appelsiinimehun askorbiini-happopitoisuus. Askorbiinihapon hajoaminen mitattiin koetölkkeihin pakatusta appelsiinimehusta, ja lämpötilan, valon ja hapen vaikutusta askorbiinihapon hajoamiseen tutkittiin 12 viikon ajan. Lämpötilalla oli suurin vaikutus askorbiinihapon hajoamiseen huolimatta käytetystä pakkausmateriaalista.