976 resultados para VENTILATION


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quasi-experimental study, prospective with quantitative approach, performed at the Hospital do Coração in Natal, aimed at verified the existence of difference between the care given by health professionals to the patients under mechanical ventilation (MV) in the Intensive Care Unit, before and after an educative intervention. The population was of 31 professionals, with data collected between november 05 of 2007 to march 27 of 2008. The results show a yong population, female gender, middle level of education, nursing technique, working between 05 and 09 years on nursing profession, and 01 to 04 years on Intensive Care Unit; almost all, never had an kind of training over prevent pneumonia associated to mechanical ventilation; from those that had training, occur on the work place with duration from 12 to 24 hours. About endotracheal intubation, the cuff was tested with a sterilized syringe had a positive change after a educative intervention, increased from 75,0% to 100,0%; the sterile guide was used on 75,0% before and 100,0% after an educative intervention. Regarding endotracheal suction procedure, was not informed to the patient on 72,7% before, however was informed on 56,7% after; the hands was not previously washed 68,5% before, however was 63,3% after the procedure; mask was used on 74,2 % opportunities before and 76,7% after; the aspiration catheter had adequated size on 98,9% observation before and 100,0% after; the gaze was sterilized on 95,7% before and 100,0% after; the ventilator was connected to the patient during the aspiration intervals on 94,4% observation before and 100,0% after; the ambu bag was clean and protected on 76,1% before and 85,7% after; the aspiration catheter was discarded after be used on 98,9% before and 100,0% after; FIO2 was turned to the begging value on 32,9% observation before and 12,0% after; before the procedure 71,9% professions washed their hands and 73,3% after; before, notes of aspiration results were performed on 70,8% observation and 86,7% after. Regarding devices used on respiratory tract, aspirator flasks were not swapped on 84,6% observations before and 71,0% after; daily látex extention change was not performed on 93,6% observation before and 87,1% after; the ambu bag change was not performed on 50,0% observation before even if was duty or unprotected and on 75,8% opportunities was changed, after; nebulization was not prepared with sterile fluids or manipulated aseptically on 65,2% observation before, perhaps was on 71,7% after; before nebulizers were not changed on 65,2% observations, perhaps were on 60,9% after. Concerning ventilator breathing circuits, condense fluids cumulated on circuits were removed on 55,0% opportunities before, and 64,0% after; moisturizer was not filled with sterile water when already had small amount of liquid inside on 78,4% observations before, and 90,2% after; MV circuits were changed on 97,0% observations on presence of visible duty or when presents some kind of failure, before and 98,4% after. About body position, on 51,3% observations the decubitus position change were done before and 78,2% after; fowler position was maitened on 95,5% observations before and 98,2% after; Regarding respiratory physiotherapy, enteral diet was not interrupted before respiratory physiotherapy on 94,9% before and 90,0% after; respiratory physiotherapy devices were not disinfected or sterile on 69,6% observations before but they re on 60,0% after; before the cateter was not tested before introduction enteral diet or medications on 100,0% but after was done on 15,2%. About enteral feeding, intestine motility and measure of stomach contents were not done on 100,0% observations before, but was 15,2% after. We conclude that 05 of 07 valuated procedures in relation to MV, had a significant improvement on quality of care given after educative intervention, when compared before intervention

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar a influência de cobertura de quitosana na pós-colheita de mangas 'Tommy Atkins', colhidas de vez e armazenadas a 23 ºC (65% UR). As mangas foram adquiridas na CEAGESP de Ribeirão Preto-SP, e transportadas ao Laboratório de Tecnologia de Produtos Agrícolas da UNESP de Jaboticabal. Após a seleção, os frutos foram higienizados em solução de dicloro s. triazinatriona sódica di-hidratada (Sumaveg®) a 200 mg 100g-1 de cloro livre por 10 minutos, secadas, imersas nas soluções a 0%; 1,0%; 1,5% e 2,0% de quitosana por 1 minuto, secadas sob ventilação, acondicionadas em bandejas e armazenadas a 23±2 °C e 65±5% UR, por 9 dias. Foram utilizados três repetições com dois frutos cada. Avaliaram-se, a cada três dias, a perda de massa fresca, a cor, a firmeza, os teores de ácido ascórbico, de sólidos solúveis, de acidez titulável e sólidos solúveis / acidez titulável. O recobrimento com quitosana retarda o amadurecimento de mangas 'Tommy Atkins' de vez, durante nove dias de armazenamento a 23 ºC, sendo que a concentração de 1,5% propicia melhor manutenção da cor da polpa, dos teores de sólidos solúveis, de acidez titulável, de ácido ascórbico, dos valores de SS/AT e de firmeza.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Synbranchus marmoratus is a facultative air-breathing fish, which uses its buccal cavity as well as its gills for air-breathing. S. marmoratus shows a very pronounced tachycardia when it surfaces to air-breathe. An elevation of heart rate decreases cardiac filling time and therefore may cause a decline in stroke volume (VS), but this can be compensated for by an increase in venous tone to maintain stroke volume. Thus, the study on S. marmoratus was undertaken to investigate how stroke volume and venous function are affected during air-breathing. To this end we measured cardiac output (Q), heart rate (fH), central venous blood pressure (PCV), mean circulatory filling pressure (MCFP), and dorsal aortic blood pressures (PDA) in S. marmoratus. Measurements were performed in aerated water (P-O2 > 130 mmHg), when the fish alternated between gill ventilation and prolonged periods of apnoeas, as well as during hypoxia (P-O2 <= 50 mmHg), when the fish changed from gill ventilation to air-breathing. Q increased significantly during gill ventilation compared to apnoea in aerated water through a significant increase in both fH and VS. PCV and MCFP also increased significantly. During hypoxia, when the animals surface to ventilate air, we found a marked rise in fH, PCV, MCFP, Q and VS, whereas PDA decreased significantly. Simultaneous increases in PCV and MCFP in aerated, as well as in hypoxic water, suggests that the venous system plays an important regulatory role for cardiac filling and VS in this species. In addition, we investigated adrenergic regulation of the venous system through bolus infusions of adrenergic agonists (adrenaline, phenylephrine and isoproterenol; 2 mu g kg(-1)). Adrenaline and phenylephrine caused a marked rise in PCV and MCFP, whereas isoproterenol led to a marked decrease in PCV, and tended to decrease MCFP. Thus, it is evident that stimulation of both alpha- and beta-adrenoreceptors affects venous tone in S. marmoratus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate the accumulation of matter, dry matter content of Brix and two varieties of sugar cane, influenced by the phosphorus cultivated on "Zona da Mata" region, State of Alagoas. The experiment, a factorial 2 x 6, was composed of two varieties of cane; RB867515 and RB92579 and six phosphorus levels: zero, 30, 60, 90, 120 and 150 kg ha(-1), with the source of the phosphorus triple superphosphate. Was also used nitrogen and potassium in doses equivalent to 100 and 200 kg ha(-1) and K, respectively. The soil of the experimental area was set to raise the base saturation to 60%. At the beginning of the first rainfall of the rainy season of 2006 was performed with micro fertilization in coverage, in doses equivalent to 6,0; 6,0 and 7,0 kg ha(-1) of Cu, Zn and Mn, respectively. Was The chemical control of weeds. Every month, from August to October 2006, samples were collected in the cane plant. There was initially the number of plants m(2), followed by weighing the material. It was subsequently withdrawn a subsample containing ten plants for weighing. After weighing the material was passed in horsemanship and homogenized, again drew up a sample of approximately 300g, leading them to forced ventilation oven at 65 degrees C, toobtain constant weight. Resulting in the production of natural (MN) and dry matter (DM). In July, we analyzed the levels of Brix% juice in the refractometer Brix. The average values of production of natural (MN), dry matter (DM) and contents of Brix% were subjected to analysis of variance and regression for variables. The accumulation of dry matter and were influenced by fertilization. The contents of Brix% in two varieties did not suffer significant influence of fertilization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experiments were performed to study the effect of surface properties of a vertical channel heated by a source of thermal radiation to induce air flow through convection. Two channels (solar chimney prototype) were built with glass plates, forming a structure of truncated pyramidal geometry. We considered two surface finishes: transparent and opaque. Each stack was mounted on a base of thermal energy absorber with a central opening for passage of air, and subjected to heating by a radiant source comprises a bank of incandescent bulbs and were performed field tests. Thermocouples were fixed on the bases and on the walls of chimneys and then connected to a data acquisition system in computer. The air flow within the chimney, the speed and temperature were measured using a hot wire anemometer. Five experiments were performed for each stack in which convective flows were recorded with values ranging from 17 m³ / h and 22 m³ / h and air flow velocities ranging from 0.38 m / s and 0.56 m / s for the laboratory tests and air velocities between 0.6 m/s and 1.1m/s and convective airflows between 650 m³/h and 1150 m³/h for the field tests. The test data were compared to those obtained by semi-empirical equations, which are valid for air flow induced into channels and simulated data from 1st Thermodynamics equation. It was found that the chimney with transparent walls induced more intense convective flows than the chimney with matte finish. Based on the results obtained can be proposed for the implementation of prototype to exhaust fumes, mists, gases, vapors, mists and dusts in industrial environments, to help promote ventilation and air renewal in built environments and for drying materials, fruits and seeds

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os objetivos deste trabalho foram avaliar a produção de alface em ambiente protegido, utilizando diferentes compostos orgânicos como fonte de nitrogênio, e seu efeito residual em dois ciclos sucessivos. O experimento foi conduzido entre os meses de fevereiro e maio de 2005, em casa-de-vegetação com ventilação e temperatura controlados, utilizando vasos de 3,5 L e solo classificado como Latossolo Vermelho Escuro. Foram utilizados compostos orgânicos produzidos a partir da mistura de resíduos do processamento de quatro plantas medicinais e esterco bovino. Os compostos C1, C2, C3 e C4 nas doses 30, 60, 90 e 120 t ha-1 constituíram os tratamentos dispostos em delineamento inteiramente casualizado, com quatro repetições e uma testemunha (adicional). Foram determinados: matéria fresca da parte aérea (MFPA); massa de matéria seca da parte aérea (MSPA). Os compostos aplicados supriram satisfatoriamente as necessidades de nitrogênio da cultura, no primeiro ciclo, dispensando o uso de fertilizante mineral. A composição dos materiais aplicados influenciou significativamente a produção de alface no primeiro ciclo, promovendo efeito residual no segundo ciclo, porém em menores proporções.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of environmental conditions on the indoor radon daughters spatial distribution is studied both theoretically and experimentally. Simple theoretical calculations indicate that ventilation and variation in the size distribution of aerosols should play an important role influencing the spatial distribution of indoor radon decay products, but experimental results indicate that these environmental factors have little influence on the spatial distribution of radon daughters near the walls of indoor environments. We have observed that the maximum effective range of the plate-out effect varies only between I and 3 cm in typical dwellings. (C) 2002 Elsevier B.V. Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este estudo objetivou atualizar os conhecimentos em relação à utilização da ventilação mecânica não-invasiva (VMNI) no pós-operatório de cirurgia cardíaca e identificar se há indícios da superioridade de uma forma de modalidade de VMNI em relação à outra. Foi realizada revisão da literatura entre 2006 a 2011, a partir das bases de dados PubMed, SciELO e Lilacs, utilizando os descritores respiração artificial, pressão positiva contínua nas vias aéreas, ventilação com pressão positiva intermitente e cirurgia cardíaca, e seus correspondentes na língua inglesa, os quais foram pesquisados em cruzamentos. A partir dos critérios adotados, foram selecionados nove artigos, dos quais seis demonstraram aplicações de VMNI, por meio de modalidades como pressão positiva contínua nas vias aéreas, pressão positiva com dois níveis pressóricos e respiração com pressão positiva intermitente, no pós-operatório de cirurgia cardíaca, e, três realizaram comparações entre as diferentes modalidades. As modalidades de VMNI descritas na literatura foram utilizadas com resultados satisfatórios. Estudos que comparam diferentes modalidades são escassos, contudo alguns demonstraram superioridade de uma modalidade de VMNI, como é o caso da respiração com pressão positiva intermitente na reversão da hipoxemia e da pressão positiva com dois níveis pressóricos na melhora da oxigenação, da frequência respiratória e frequência cardíaca desses pacientes, em comparação a outras modalidades.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To analyze the effect of arm bracing posture on respiratory muscle strength and pulmonary function in patients with Chronic Obstructive Pulmonary Disease (COPD).Methods: 20 patients with COPD (11 male; 67 +/- 8 years; BMI 24 +/- 3 Kg . m(-2)) were submitted to assessments of Maximal Inspiratory and Expiratory Pressures (MIP and MEP, respectively) and spirometry with and without arm bracing in a random order. The assessment with arm bracing was done on standing position and the height of the support was adjusted at the level of the ulnar styloid process with elbow flexion and trunk anterior inclination of 30 degrees promoting weight discharge in the upper limbs. Assessment without arm bracing was also performed on standing position, however with the arms relaxed alongside the body. The time interval between assessments was one week.Results: MIP, MEP and maximal voluntary ventilation (MW) were higher with arm bracing than without arm bracing (MIP 64 +/- 22 cmH(2)O versus 54 +/- 24 cmH(2)O, p = 0,00001; MEP 104 +/- 37 cmH(2)O versus 92 +/- 37 cmH(2)O, p = 0,00001 and MW 42 +/- 20 L/min versus 38 +/- 20 L/min, p = 0,003). Other variables did not show statistical significant difference.Conclusion: The arm bracing posture resulted in higher capacity to generate force and endurance of the respiratory muscles in patients with COPD. (C) 2009 Published by Elsevier Espana, S.L. on behalf of Sociedade Portuguesa de Pneumologia. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar o efeito da técnica de oscilação oral de alta freqüência (com o aparelho Shaker), aplicada em diferentes pressões expiratórias (PE), sobre a função autonômica e parâmetros cardiorrespiratórios. Foram coletados dados de 20 voluntários jovens saudáveis (21,6±1,3 anos), que permaneceram em repouso inicial por 10 minutos e, em seguida, fizeram três séries de dez expirações no aparelho (com intervalo de descanso de 2 minutos entre as séries) em três diferentes PE - pressão livre (PL), de 10 (P10) e de 20 (P20) cmH2O - permanecendo por mais 10 minutos em repouso final. Os dados foram analisados estatisticamente, com nível de significância de 5%. Após a aplicação da técnica, constatou-se diferença significante nos índices de variabilidade da freqüência cardíaca em PL e um aumento significante na pressão arterial sistólica em P20. Na pressão arterial diastólica, freqüência respiratória e saturação periférica de oxigênio não foram encontradas diferenças antes, durante e após a técnica, nas diferentes PE. A percepção do esforço aumentou significantemente ao longo das séries em PL e P20 e entre P10 e P20 em cada série. A freqüência cardíaca (FC) aumentou e diminuiu em sincronia com os movimentos de inspiração e expiração, respectivamente. Foram observadas modificações na modulação autonômica do coração em PL. A aplicação da técnica nessa população, nas diferentes PE analisadas, promoveu modificações no comportamento da FC, no esforço percebido e, em PL, na modulação autonômica do coração.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Obesity impairment to the pulmonary function related to the magnitude of adiposity and is associated with excessive daytime sleepiness (EDS) and snoring, among others symptoms of respiratory disorders related to sleep. It is possible that obese individuals with excessive daytime sleepiness may make changes in lung function on spirometry monitored during the day as a consequence of fragmented sleep or episodes of nocturnal hypoventilation that cause respiratory and changes that can persist throughout the day. The combination of these findings alone sleepiness observed by subjective scales with pulmonary function in obese patients is unknown. Objective: To assess the influence of EDS and snoring on pulmonary function in morbidly obese and distinguish between different anthropometric markers, the snoring and sleepiness which the best predictors of spirometric function and respiratory muscle strength and endurance of these patients. Methods: We evaluated 40 morbidly obese markers on the anthropometric, spirometric respiratory variables, maximal inspiratory and expiratory pressures (MIP and MEP) and maximal voluntary ventilation (MVV) and the measured excessive daytime sleepiness (the Epworth sleepiness scale) and snoring (snoring scale of Stanford). The data were treated when the differences between the groups of obese patients with and without sleepiness, whereas the anthropometric variables, respiratory and snoring. Pearson's correlation was performed, and multiple regression analysis assessed the predictors of pulmonary function. For this we used the software SPSS 15.0 for windows and p <0.05. Results: 39 obese patients were included (28 women), age 36.92+11.97y, body mass index (BMI) 49.3+5.1kg/m², waist-hip ratio (WHR) 0.96+0.07 and neck circumference (NC) 44.1+4.2 cm. Spirometric values and respiratory pressures were up 80% of predicted values, except for endurance (MVV <80%). Obese with EDS have lower tidal volume. Positive correlation was observed between BMI and EDS, EDS and NC and between snoring and BMI, and negative correlation between EDS and tidal volume (TV), and between snoring and snoring FVC and FEV1. In linear regression the best predictor of pulmonary function was snoring, followed by NC. NC has more obese with higher strength (MEP, p = 0.031) and endurance (MVV p = 0.018) respiratory muscle. Conclusion: Obese with EDS tend to have lower TV. In addition, snoring and NC can better predict pulmonary function in obese when compared with other anthropometric markers or EDS. Obese patients with higher NC tend to have greater capacity for overall strength of respiratory muscles, but may have low muscle endurance

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The clinical importance of evaluating the respiratory muscles with a variety of tests has been proposed by several studies, once that the combination of several tests would allow a better diagnosis and therefore, a better clinical follow of disorders of the respiratory muscles. This study aimed to evaluate the feasibility of adapting a national electronic manovacuometer to measure the nasal inspiratory pressure (study 1) and analyze the level of load intensity of maximum voluntary ventilation, as well as the variables that may influence this maneuver in healthy subjects (study 2). We studied 20 healthy subjects by a random evaluation of two measures of SNIP in different equipments: a national and an imported. In study 2 it was analyzed the intensity of the load of MVV test, change in pressure developed during the maneuver, the possible differences between genders, and the correlations between the flow developed in the test and the result of MVV. In study 1 it was found the average for both measures of nasal inspiratory pressures: 125 ± 42.4 cmH2O for the imported equipment and 131.7 ± 28.7 cmH2O for the national one. Pearson analysis showed a significant correlation between the average, with a coefficient r = 0.63. The average values showed no significant differences evaluated by paired t test (p> 0.05). In the Bland-Altman analysis it was found a BIAS = 7 cmH2O, SD 32.9 and a confidence interval of - 57.5 cmH2O up to 71.5 cmH2O. In the second study it was found significant differences between the genders in the air volume moved, being higher in males 150.9 ± 13.1 l / min vs 118.5 ± 15.7 L / min for (p = 0.0002, 95% CI 44.85 to 20:05). Regarding the inspiratory and expiratory loading, they were significantly higher in men than in women, peak inspiratory pressure (34.7 ± 5.3 cmH2O vs 19.5 ± 4.2 cmH2O, 95% CI - 18.0 to -12.3, p <0.0001), peak expiratory (33.8 vs. 23.1 ± 5.9 cmH2O ± 5.4 cmH2O, 95% CI -17.1 to - 4.6, p <0.0001), and the delta pressure (59.7 ± 10 cmH2O vs 36.8 ± 8.3 cmH2O, 95% CI 14.5 to 31.2, p <0.0002). The Pearson correlation showed that the flow generated by the maneuver is strongly correlated with the delta-expiratory pressure / inspiratory (r2= 0.83,R = 0.91, 95%IC 0.72 a 0.97 e p< 0.0001).Through these results we suggest that the national electronic manovacuometer is feasible and safe to perform the sniff test in healthy subjects. For the MVV, there are differences between the genders in the intensity of pressure developed during the maneuver. We found a load intensity considered low during the MVV, and found a strong correlation between the flow generated in the test and the delta pressure expiratory / inspiratory

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Obesity may affect the respiratory system, causing changes in respiratory function and in the pulmonary volumes and flows. Objectives: To evaluate the influence of obesity in the movement of thoracoabdominal complex at rest and during maximal voluntary ventilation (MVV), and the contribution between the different compartments of this complex and the volume changes of chest wall between obese and non-obese patients. Materials and Methods: We studied 16 patients divided into two groups: the obese group (n = 8) and group non-obese (n = 8). The two groups were homogeneous in terms of spirometric characteristics (FVC mean: 4.97 ± 0.6 L - 92.91 ± 10.17% predicted, and 4.52 ± 0.6 L - 93.59 ± 8.05%), age 25.6 ± 5.0 and 26.8 ± 4.9 years, in non-obese and obese respectively. BMI was 24.93 ± 3.0 and 39.18 ± 4.3 kg/m2 in the groups investigated. All subjects performed breathing calm and slow and maneuver MVV, during registration for optoelectronic plethysmography. Statistical analysis: we used the unpaired t test and Mann-Whitney. Results: Obese individuals had a lower percentage contribution of the rib cage abdominal (RCa) during breathing at rest and VVM. The variation of end expiratory (EELV) and end inspiratory (EILV) lung volumes were lower in obese subjects. It has been found asynchrony and higher distortion between compartments of thoracoabdominal complex in obese subjects when compared to non-obese. Conclusions: Central obesity impairs the ventilation lung, reducing to adaptation efforts and increasing the ventilatory work

Relevância:

10.00% 10.00%

Publicador:

Resumo:

obesity affects rightly functional capacity diminishing the cardiovascular system efficiency and oxygen uptake (VO2). Field tests, such as, Incremental Shuttle Walking Test (ISWT) and Six Minute Walk Test (6MWT) has been employed as alternative of Cardiopulmonary Exercise Test (CPX), to functional assessing for conditions which transport of oxygen to peripheral is diminished. Nevertheless, the knowing about metabolic variables response in real time and it comparing among different maximal and submaximal tests in obese is absent. Aim: to compare cardiopulmonary, metabolic response during CPX, ISWT and 6MWT and to analyse it influence of adiposity markers in obese. Material e Method: crosssectional, prospective study. Obese included if: (BMI>30Kg/m2; FVC>80%), were assessed as clinical, anthropometric (BMI, body adiposity index-BAI, waist-WC, hip- HC and neck-NC circumferences) and spirometry (forced vital capacity-FVC, Forced expiratory volume-1°second-FEV1, maximal voluntary ventilation-MVV) variables. Obese performed the sequence of tests: CPX, ISWT and 6MWT. Throughout tests was assessed breath-by-breath by telemetry system (Cortex-Biophysik-Metamax3B) variables; oxygen uptake on peak of activity (VO2peak); carbon dioxide production (VCO2); Volume Expiratory (VE); ventilatory equivalents for VO2 (VE/VO2) and CO2 (VE/VCO2); respiratory exchange rate (RER) and perceived effort-Borg6-20). Results: 15 obese (10women) 39.4+10.1years, normal spirometry (%CVF=93.7+9.7) finished all test. They have BMI (43.5+6.6kg/m2) and different as %adiposity (BAI=50.0+10.5% and 48.8+16.9% respectively women and men). Difference of VO2ml/kg/min and %VO2 were finding between CPX (18.6+4.0) and 6MWT (13.2+2.5) but not between ISWT (15.4+2.9). Agreement was found for ISWT and CPX on VO2Peak (3.2ml/kg/min; 95%; IC-3.0 9.4) and %VO2 (16.4%). VCO2(l/min) confirms similarity in production for CPX (2.3+1.0) and ISWT (1.7+0.7) and difference for 6MWT (1.4+0.6). WC explains more the response of CPX and ISWT than other adiposity markers. Adiposity diminishes 3.2% duration of CPX. Conclusion: ISWT promotes similar metabolic and cardiovascular response than CPX in obese. It suggesting that ISWT could be useful and reliable to assess oxygen uptake and functional capacity in obese

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective-To evaluate the cardiorespiratory and intestinal effects of the muscarinic type-2 (M-2) antagonist, methoctramine, in anesthetized horses.Animals-6 horses.Procedure-Horses were allocated to 2 treatments in a randomized complete block design. Anesthesia was maintained with halothane (1% end-tidal concentration) combined with a constant-rate infusion of xylazine hydrochloride (1 mg/kg/h, IV) and mechanical ventilation. Hemodynamic variables were monitored after induction of anesthesia and for 120 minutes after administration of methoctramine or saline (0.9% NaCl) solution (control treatment). Methoctramine was given at 10-minute intervals (10 mug/kg, IV) until heart rate (HR) increased at least 30% above baseline values or until a maximum cumulative dose of 30 mug/kg had been administered. Recovery characteristics, intestinal auscultation scores, and intestinal transit determined by use of chromium oxide were assessed during the postanesthetic period.Results-Methoctramine was given at a total cumulative dose of 30 mug/kg to 4 horses, whereas 2 horses received 10 mug/kg. Administration of methoctramine resulted in increases in HR, cardiac output, arterial blood pressure, and tissue oxygen delivery. Intestinal auscultation scores and intestinal transit time (interval to first and last detection of chromium oxide in the feces) did not differ between treatment groups.Conclusions and Clinical Relevance-Methoctramine improved hemodynamic function in horses anesthetized by use of halothane and xylazine without causing a clinically detectable delay in the return to normal intestinal motility during the postanesthetic period. Because of their selective positive chronotropic effects, M-2 antagonists may represent a safe alternative for treatment of horses with intraoperative bracycardia.