951 resultados para Ultrassonografia color Doppler
Resumo:
The identification of color vision types in primates is fundamental to understanding the evolution and biological function of color perception. The Hard, Randy, and Rittler (HRR) pseudoisochromatic test categorizes human color vision types successfully. Here we provide an experimental setup to employ HRR in a nonhuman primate, the capuchin (Cebus libidinosus), a platyrrhine with polymorphic color vision. The HRR test consists of plates with a matrix composed of gray circles that vary in size and brightness. Differently colored circles form a geometric shape (X, O, or Delta) that is discriminated visually from the gray background pattern. The ability to identify these shapes determines the type of dyschromatopsy (deficiency in color vision). We tested six capuchins in their own cages under natural sunlight. The subjects chose between two HRR plates in each trial: one with the gray pattern only and the other with a colored shape, presented on the left or right side at random. We presented the test 40 times and calculated the 95 % confidence limits for chance performance based on the binomial test. We also genotyped all subjects for exons 3 and 5 of the X-linked opsin genes. The HRR test diagnosed two subjects as protan dichromats (missing or defective L-cone), three as deutan dichromats (missing or defective M-cone), and one female as trichromat. Genetic analysis supported the behavioral data for all subjects. These findings show that the HRR test can be applied to diagnose color vision in nonhuman primates.
Resumo:
The purpose of this study was to evaluate the visual outcome of chronic occupational exposure to a mixture of organic solvents by measuring color discrimination, achromatic contrast sensitivity and visual fields in a group of gas station workers. We tested 25 workers (20 males) and 25 controls with no history of chronic exposure to solvents (10 males). All participants had normal ophthalmologic exams. Subjects had worked in gas stations on an average of 9.6 +/- 6.2 years. Color vision was evaluated with the Lanthony D15d and Cambridge Colour Test (CCT). Visual field assessment consisted of white-on-white 24-2 automatic perimetry (Humphrey II-750i). Contrast sensitivity was measured for sinusoidal gratings of 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 and 20.0 cycles per degree (cpd). Results from both groups were compared using the Mann-Whitney U test. The number of errors in the D15d was higher for workers relative to controls (p<0.01). Their CCT color discrimination thresholds were elevated compared to the control group along the protan, deutan and tritan confusion axes (p<0.01), and their ellipse area and ellipticity were higher (p<0.01). Genetic analysis of subjects with very elevated color discrimination thresholds excluded congenital causes for the visual losses. Automated perimetry thresholds showed elevation in the 9 degrees, 15 degrees and 21 degrees of eccentricity (p<0.01) and in MD and PSD indexes (p<0.01). Contrast sensitivity losses were found for all spatial frequencies measured (p<0.01) except for 0.5 cpd. Significant correlation was found between previous working years and deutan axis thresholds (rho = 0.59; p<0.05), indexes of the Lanthony D15d (rho = 0.52; p<0.05), perimetry results in the fovea (rho = -0.51; p<0.05) and at 3, 9 and 15 degrees of eccentricity (rho = -0.46; p<0.05). Extensive and diffuse visual changes were found, suggesting that specific occupational limits should be created.
Resumo:
Objectives: To determine the correlation between ph at birth and venous Doppler parameters in pregnancies with placental dysfunction. Methods: This was a prospective cohort study of 58 pregnancies with the diagnosis of placental dysfunction between 26 and 34 weeks of gestation. Inclusion criteria were singleton pregnancies, abnormal umbilical artery (UA) Doppler, fetal growth restriction diagnosed by estimated fetal weight <10th centile for gestational age, intact membranes, and absence of fetal congenital abnormalities. The Doppler measurements were the following: UA pulsatility index (PI), ductus venosus (DV) pulsatility index for veins (PIV), intra-abdominal umbilical vein (UV) time-averaged maximum velocity (TAMxV) and blood flow and left portal vein (LPV) time-averaged maximum velocity (TAMxV) and blood flow. All Doppler parameters were transformed into z-scores (SD values from the mean) according to normative references. Results: The UA pH at birth showed a negative significant correlation with the DV-PIV (p = 0.004) and the DV-PIV z-score (p = 0.004), while LPV TAMxV (p = 0.004), LPV TAMxV z-score (p = 0.002), LPV blood flow (p = 0.01), LPV blood flow normalized (p = 0.04) and UV blood flow (p = 0.04) positively correlated with pH at birth. Multiple regression analysis was performed and the DV-PIV z-score was the variable that independently correlated with pH at birth (p = 0.002). Conclusions: the present results suggest that changes in fetal venous blood flow, mainly DV and LPV are useful in the management of cases with early onset placental insufficiency and that venous Doppler parameters correlate with pH at birth.
Resumo:
Object. Sonothrombolysis has recently been considered an emerging modality for the treatment of stroke. The purpose of the present paper was to review randomized clinical studies concerning the effects of sonothrombolysis associated with tissue plasminogen activator (tPA) on acute ischemic stroke. Methods. Systematic searches for literature published between January 1996 and July 2011 were performed for studies regarding sonothrombolysis combined with tPA for acute ischemic stroke. Only randomized controlled trials were included. Data extraction was based on ultrasound variables, patient characteristics, and outcome variables (rate of intracranial hemorrhages and arterial recanalization). Results. Four trials were included in this study; 2 trials evaluated the effect of transcranial Doppler (TCD) ultrasonography on sonothrombolysis, and 2 addressed transcranial color-coded duplex (TCCD) ultrasonography. The frequency of ultrasound waves varied from 1.8 to 2 MHz. The duration of thrombus exposure to ultrasound energy ranged from 60 to 120 minutes. Sample sizes were small, recanalization was evaluated at different time points (60 and 120 minutes), and inclusion criteria were heterogeneous. Sonothrombolysis combined with tPA did not lead to an increase in symptomatic intracranial hemorrhagic complications. Two studies demonstrated that patients treated with ultrasound combined with tPA had statistically significant higher rates of recanalization than patients treated with tPA alone. Conclusions. Despite the heterogeneity and the limitations of the reviewed studies, there is evidence that sonothrombolysis associated with tPA is a safe procedure and results in an increased rate of recanalization in the setting of acute ischemic stroke when wave frequencies and energy intensities of diagnostic ultrasound systems are used. (http://thejns.org/doi/abs/10.3171/2011.10.FOCUS11251)
Resumo:
This study evaluated the influence of beverages and brushing on the surface roughness(SR) and color change(Delta E) of a composite resin. For this, 120-disks(10 mmx2 mm) of composite resin(Filtek-Z250) were prepared and polished. Initials SR(Ra-mu m) and color(CIELab-system) were measured with rugosimeter and spectrophotometer; specimens were divided into four groups(red wine, soft drink, sugar cane spirit, or artificial saliva=control) and three subgroups(without brushing; brushed with Colgate or with Close-Up). Specimens were immersed in the beverage 5x/day, for 5', over 30 day, being two subgroups brushed(120 strokes/day). Color was measured at 15th day, 30th day and after repolishment; SR at 30th day. Delta E-values were statistically different after immersion in the beverages(p<0.05). Red wine promoted the highest alteration, followed by soft drink=sugar cane spirit and finally saliva. At 30th day, specimens exhibited Delta E higher than 15th day; after repolishing, Delta E was similar to 15th day. Beverages and brushing negatively influenced the SR. Therefore, Delta E and SR can be influenced by beverages and brushing.
Resumo:
Neurosonological studies, specifically transcranial Doppler (TCD) and transcranial color-coded duplex (TCCD), have high level of specificity and sensitivity and they are used as complementary tests for the diagnosis of brain death (BD). A group of experts, from the Neurosonology Department of the Brazilian Academy of Neurology, created a task force to determine the criteria for the following aspects of diagnosing BD in Brazil: the reliability of TCD methodology; the reliability of TCCD methodology; neurosonology training and skills; the diagnosis of encephalic circulatory arrest; and exam documentation for BD. The results of this meeting are presented in the current paper.