976 resultados para Tomodensitométrie ou computed tomogrpahy (CT)
Resumo:
AIM: Contribution of 3-phase 18F-fluorocholine PET/CT in suspected prostate cancer recurrence at early rise of PSA. PATIENTS, METHODS: Retrospective analysis was performed in 47 patients after initial treatment with radiotherapy (n=30) or surgery (n=17). Following CT, 10 minutes list-mode PET acquisition was done over the prostate bed after injection of 300 MBq of 18F-fluorocholine. Three timeframes of 3 minutes each were reconstructed for analysis. All patients underwent subsequent whole body PET/CT. Delayed pelvic PET/CT was obtained in 36 patients. PET/CT was interpreted visually by two observers and SUVmax determined for suspicious lesions. Biopsies were obtained from 13 patients. RESULTS: Biopsies confirmed the presence of cancer in 11 of 13 patients with positive PET for a total of 15 local recurrences in which average SUVmax increased during 14 minutes post injection and marginally decreased in delayed scanning. Conversely inguinal lymph nodes with mild to moderate metabolic activity on PET showed a clearly different pattern with decreasing SUVmax on dynamic images. Three-phase PET/CT contributed to the diagnostic assessment of 10 of 47 patients with biological evidence of recurrence of cancer. It notably allowed the discrimination of confounding blood pool or urinary activity from suspicious hyperactivities. PET/CT was positive in all patients with PSA>or=2 ng/ml (n=34) and in 4/13 patients presenting PSA values<2 ng/ml. CONCLUSION: 18F-fluorocholine 3-phase PET/CT showed a progressively increasing SUVmax in biopsy confirmed cancer lesions up to 14 minutes post injection while decreasing in inguinal lymph nodes interpreted as benign. Furthermore, it was very useful in differentiating local recurrences from confounding blood pool and urinary activity.
Resumo:
Introduction : Les tumeurs solides pseudo-papillaires du pancréas (SPT) sont des tumeurs rares, d'étiopathogénie encore incertaine.Le but de notre travail était de décrire les caractéristiques radiologiques des SPT dans le groupe d'âge pédiatrique et d'étudier leur corrélation avec les études anatomopathologiques en vue d'établir un diagnostic.Patients et Méthodes : Nous avons étudié rétrospectivement trois malades pédiatriques pour lesquelles le diagnostic de tumeur solide pseudo-papillaire du pancréas a été porté à l'examen d'une pièce opératoire. Ce groupe comprenait 3 jeunes filles et femmes (âge médian: 13 ans).Résultats : La tumeur a été découverte pendant le bilan de symptômes digestifs non spécifiques. Les examens biologiques n'étaient pas informatifs. Des investigations radiologiques complètes ont été réalisées y compris les ultrasons (US), la tomodensitométrie (CT) et l'imagerie par résonance magnétique (IRM).Celles-ci ont montré de volumineuses lésions nodulaires, peu vascularisées, de compositions habituellement hétérogènes, avec des composantes kystiques et hémorragiques identifiées dans les 3 cas. Un traitement chirurgical a été pratiqué chez toute les patientes. L'étude de la pièce opératoire a montré une tumeur encapsulée dans les 3 cas. Aucune métastase n'a été mise en évidence.Conclusion : Les SPT doivent être considérées dans le diagnostic différentiel des masses pancréatiques pédiatriques, en particulier chez les adolescentes. Certaines caractéristiques radiologiques comme des masses volumineuses bien circonscrites, des lésions hétérogènes avec des zones kystiques et hémorragiques, de plus entourées d'une pseudocapsule fibreuse réactive, suggèrent fortement le diagnostic de SPT. Celui-ci devrait ensuite être confirmé par une biopsie avant que la résection chirurgicale soit effectuée. Chez les enfants, Γ écho graphie abdominale reste la méthode de première intention, suivie par l'IRM comme technique d'imagerie de choix pour évaluer les caractéristiques et l'extension de la lésion, tout en évitant l'exposition des patients aux rayonnements ionisants.
Resumo:
The three-dimensional (3D) correction of glenoid erosion is critical to the long-term success of total shoulder replacement (TSR). In order to characterise the 3D morphology of eroded glenoid surfaces, we looked for a set of morphological parameters useful for TSR planning. We defined a scapular coordinates system based on non-eroded bony landmarks. The maximum glenoid version was measured and specified in 3D by its orientation angle. Medialisation was considered relative to the spino-glenoid notch. We analysed regular CT scans of 19 normal (N) and 86 osteoarthritic (OA) scapulae. When the maximum version of OA shoulders was higher than 10°, the orientation was not only posterior, but extended in postero-superior (35%), postero-inferior (6%) and anterior sectors (4%). The medialisation of the glenoid was higher in OA than normal shoulders. The orientation angle of maximum version appeared as a critical parameter to specify the glenoid shape in 3D. It will be very useful in planning the best position for the glenoid in TSR.
Resumo:
BACKGROUND: Radiation dose exposure is of particular concern in children due to the possible harmful effects of ionizing radiation. The adaptive statistical iterative reconstruction (ASIR) method is a promising new technique that reduces image noise and produces better overall image quality compared with routine-dose contrast-enhanced methods. OBJECTIVE: To assess the benefits of ASIR on the diagnostic image quality in paediatric cardiac CT examinations. MATERIALS AND METHODS: Four paediatric radiologists based at two major hospitals evaluated ten low-dose paediatric cardiac examinations (80 kVp, CTDI(vol) 4.8-7.9 mGy, DLP 37.1-178.9 mGy·cm). The average age of the cohort studied was 2.6 years (range 1 day to 7 years). Acquisitions were performed on a 64-MDCT scanner. All images were reconstructed at various ASIR percentages (0-100%). For each examination, radiologists scored 19 anatomical structures using the relative visual grading analysis method. To estimate the potential for dose reduction, acquisitions were also performed on a Catphan phantom and a paediatric phantom. RESULTS: The best image quality for all clinical images was obtained with 20% and 40% ASIR (p < 0.001) whereas with ASIR above 50%, image quality significantly decreased (p < 0.001). With 100% ASIR, a strong noise-free appearance of the structures reduced image conspicuity. A potential for dose reduction of about 36% is predicted for a 2- to 3-year-old child when using 40% ASIR rather than the standard filtered back-projection method. CONCLUSION: Reconstruction including 20% to 40% ASIR slightly improved the conspicuity of various paediatric cardiac structures in newborns and children with respect to conventional reconstruction (filtered back-projection) alone.
Resumo:
Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.
Resumo:
Postmortem imaging is increasingly used in forensic practice in cases of natural deaths related to cardiovascular diseases, which represent the most common causes of death in developed countries. While radiological examination is generally considered to be a good complement for conventional autopsy, it was thought to have limited application in cardiovascular pathology. At present, multidetector computed tomography (MDCT), CT angiography, and cardiac magnetic resonance imaging (MRI) are used in postmortem radiological investigation of cardiovascular pathologies. This review presents the actual state of postmortem imaging for cardiovascular pathologies in cases of sudden cardiac death (SCD), taking into consideration both the advantages and limitations. The radiological evaluation of ischemic heart disease (IHD), the most frequent cause of SCD in the general population of industrialized countries, includes the examination of the coronary arteries and myocardium. Postmortem CT angiography (PMCTA) is very useful for the detection of stenoses and occlusions of coronary arteries but less so for the identification of ischemic myocardium. MRI is the method of choice for the radiological investigation of the myocardium in clinical practice, but its accessibility and application are still limited in postmortem practice. There are very few reports implicating postmortem radiology in the investigation of other causes of SCD, such as cardiomyopathies, coronary artery abnormalities, and valvular pathologies. Cardiomyopathies representing the most frequent cause of SCD in young athletes cannot be diagnosed by echocardiography, the most widely available technique in clinical practice for the functional evaluation of the heart and the detection of cardiomyopathies. PMCTA and MRI have the potential to detect advanced stages of diseases when morphological substrate is present, but these methods have yet to be sufficiently validated for postmortem cases. Genetically determined channelopathies cannot be detected radiologically. This review underlines the need to establish the role of postmortem radiology in the diagnosis of SCD.
Resumo:
BACKGROUND AND PURPOSE: Multi-phase postmortem CT angiography (MPMCTA) is increasingly being recognized as a valuable adjunct medicolegal tool to explore the vascular system. Adequate interpretation, however, requires knowledge about the most common technique-related artefacts. The purpose of this study was to identify and index the possible artefacts related to MPMCTA. MATERIAL AND METHODS: An experienced radiologist blinded to all clinical and forensic data retrospectively reviewed 49 MPMCTAs. Each angiographic phase, i.e. arterial, venous and dynamic, was analysed separately to identify phase-specific artefacts based on location and aspect. RESULTS: Incomplete contrast filling of the cerebral venous system was the most commonly encountered artefact, followed by contrast agent layering in the lumen of the thoracic aorta. Enhancement or so-called oedematization of the digestive system mucosa was also frequently observed. CONCLUSION: All MPMCTA artefacts observed and described here are reproducible and easily identifiable. Knowledge about these artefacts is important to avoid misinterpreting them as pathological findings.
Resumo:
Decision to revascularize a patient with stable coronary artery disease should be based on the detection of myocardial ischemia. If this decision can be straightforward with significant stenosis or in non-significant stenosis, the decision with intermediate stenosis is far more difficult and require invasive measures of functional impact of coronary stenosis on maximal blood (flow fractional flow reserve=FFR). A recent computer based method has been developed and is able to measure FFR with data acquired during a standard coronary CT-scan (FFRcT). Two recent clinical studies (DeFACTO and DISCOVER-FLOW) show that diagnostic performance of FFRcT was associated with improved diagnostic accuracy versus standard coronary CT-scan for the detection of myocardial ischemia although FFRcT need further development.
Resumo:
PURPOSE: To investigate the dual-energy CT behavior of cocaine and heroin and of typical adulterants, and to evaluate the elemental composition of pure cocaine and heroin compared with cocaine and heroin in bodypacks. METHODS: Pure heroin and pure synthetic cocaine samples, eight different adulterants, and in each case ten different bodypacks containing cocaine or heroin, were imaged at 80, 100, 120, and 140 kVp in a dual source CT system at two different degrees of compression. Two radiologists, blinded to the samples, measured the attenuation. The dual-energy index (DEI) was calculated. We performed atomic mass spectrometry for the elemental analysis of pure cocaine, pure heroin, and heroin and cocaine in bodypacks, and 140 kVp in a dual-source CT system. RESULTS: Inter- and intra-observer agreement for attenuation measurements was good (r = 0.61-0.72; p < 0.01). The cocaine bodypacks had a positive DEI of 0.029, while the pure drugs and the heroin bodypacks had a negative DEI (-0.051 to -0.027). Levamisole was the only substance which expressed a positive DEI of 0.011, while the remaining adulterants had negative DEIs ranging between -0.015 and -0.215. Atomic mass spectrometry revealed a concentration of tin in the cocaine bodypack that was 67 times higher than in the pure synthetic cocaine sample. CONCLUSIONS: The different DEIs of bodypacks containing cocaine and heroin allow them to be distinguished with dual-energy CT. Although the material properties of pure cocaine, pure heroin, or common drug extenders do not explain the differences in DEI, tin contamination during illicit natural cocaine production may be a possible explanation.
Resumo:
Die Diagnostik des plötzlichen Herztods durch bildgebende Techniken ist bislang unzureichend evaluiert. Als Validierungsoption für postmortale koronarangiographische Methoden steht der Sektionsbefund zur Verfügung. Sequenziell postmortal durchgeführte alternative angiographische Methoden sind denkbar. Schließlich bietet die ante mortem durchgeführte Koronarangiographie (CA) - ggf. In Verbindung mit der perkutanen transluminalen Koronarangioplastie (PTCA) - weitere Vergleichsmöglichkeiten. Neben deskriptiven sind hier auch potenziell funktionelle Aussagen zum Stenosegrad möglich.