968 resultados para Thermoset resins


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aiming to investigate in vitro the behavior of esthetic veneers placed in crows and made of the laboratory resins Artglass and Targis when submitted to insertion and removal of circunferential cobalt-chromium clasps, 24 veneer crowns were made (twelve with Artglass (Heraeus Kulzer) and twelve with Targis (Ivoclar Vivadent)), as well as the respective cobalt-chromium clasps. The crowns were then submitted to five thousand cycles of clasps insertion and removal, using a proper device. Using the verification of the force necessary to remove the clasps over the crowns during the experiment, the clasps and crowns mass variation, and the macroscopic inspection of the veneers, one may conclude that the veneers did not show a significant variation of the force required to remove the clasps over the crowns; they show a little amount of abrasion, possible to detect using a visual inspection and they show a little and variable amount of mass loss, less for that made with Artglass (average of 0,002g) and greater for that made with Targis (average of 0,006g)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Novos compósitos têm surgido no mercado especificamente destinados à confecção de restaurações estéticas posteriores. Entretanto, embora tais materiais apresentem resultados iniciais animadores, há a necessidade de comprovações adicionais para que possam ser utilizados com segurança. Resinas compostas posteriores são submetidas a estresses complexos de compressão e abrasão durante a mastigação e a aplicação de selantes superficiais tem sido relatada como forma de aumentar a resistência ao desgaste destes materiais. O presente trabalho teve como propósito avaliar a dureza e a resistência à compressão das resinas compostas Alert (Jeneric/Pentron), Ariston (Vivadent), Definite (Degussa), P60 (3M), Solitarie (Kulzer), Surefil (Dentsply) e Z100 (3M) após 90 dias de imersão em água destilada, recobertas com selante Protect It (Jeneric/Pentron) e submetidas à ciclagem mecânica (10.000 ciclos, 600N, 5Hz). Os ensaios de dureza (n=8) foram realizados em aparelho Wolpert, com diamante Vickers e peso de 50gf aplicado por 30 segundos, antes e após períodos de imersão de 30, 60 e 90 dias. Os ensaios de resistência à compressão (n=8) foram realizados somente após 90 dias, em corpos-de-prova cilíndricos medindo 8mm de altura por 4mm de diâmetro. Apenas os espécimes destinados à compressão foram ciclados mecanicamente. Os ensaios foram realizados em máquina MTS 810, equipada com célula de carga de 10kN (ciclagem) e 100kN (compressão) e velocidade de 0,5mm/min. Após análise de variância (p<0,05), os resultados mostraram, previamente à imersão, maiores valores de dureza para os materiais Z100 (74,253VHN) e Ariston (71,308VHN). A seguir, com valor semelhante à resina Ariston, mas inferior à resina Z100, apresentou-se o material Surefil (69,969VHN)...(Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recentemente, foram lançados no mercado odontológico novos materiais estéticos para restaurações diretas em dentes posteriores, aos quais são atribuídas propriedades mais adequadas para essa indicação. Entretanto, as informações disponíveis são ainda muito escassas, gerando dúvidas quanto à sua real eficácia, sobre quais as diferenças de suas composições e propriedades físicas e mecânicas em relação aos materiais até então disponíveis e se, de fato, apresentam melhor performance clínica. Em vista do exposto, nos propusemos a estudar contração de polimerização, resistência à flexão e concentração de partículas inorgânicas, por massa e volume, de sete resinas compostas (Alert, Ariston, Solitaire, Definite, Filtek P60, Z-100 e Tetric Ceram). A contração de polimerização foi medida nos materiais inseridos em um anel plástico, e o registro das alterações, durante a polimerização, foi feito por meio de instrumento eletrônico de medida linear, que registra as alterações dimensionais, com sensibilidade de 1 mm. A resistência à flexão foi medida na máquina de ensaios mecânicos MTS 810 e a confecção dos corpos-de-prova e dos dispositivos para o ensaio foi orientada pela norma ISO no 4049:1988. A determinação do conteúdo de partículas inorgânicas por massa foi feita através da pesagem de uma porção de resina composta polimerizada antes e após a eliminação da fase orgânica em forno, à temperatura de 700oC. O porcentual volumétrico de partículas inorgânicas foi calculado com base no Princípio de Arquimedes. Foi determinado o volume da resina composta polimerizada, antes e após a eliminação da fase orgânica, pela diferença da massa do material pesado ao ar e imerso em água. Os dados de conteúdo de partículas inorgânicas por massa e por volume, de contração de polimerização e resistência à flexão foram submetidos...(Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PurposeThe mechanical properties of acrylic resins used in intraoral prostheses may be altered by frequent exposure to liquids such as beverages and mouthwashes. This study aimed to evaluate the effect of thermocycling and liquid immersion on the hardness of four brands of acrylic resins commonly used in removable prostheses (Onda Cryl, QC-20, Classico, Lucitone).Materials and MethodsFor each brand of resin, seven specimens were immersed in each of six solutions (coffee, cola, red wine, Plax-Colgate, Listerine [LI], Oral B), and seven more were placed in artificial saliva (control). The hardness was tested using a microhardness tester before and after 5000 thermocycles and after 1, 3, 24, 48, and 96 hours of immersion. The results were analyzed using three-way repeated-measures ANOVA and Tukey's test (p < 0.05).ResultsThe hardness of the resins decreased following thermocycling and immersion in the solutions. Specimens immersed in cola and wine exhibited significant decreases in hardness after immersion for 96 hours, although the greatest significant decrease in hardness occurred in specimens immersed in LI. However, according to American Dental Association specification 12, the Knoop hardness of acrylic resins for intraoral prostheses should not be below 15. Thus, the median values of superficial hardness observed in most of the acrylic resins in this study are considered clinically acceptable.ConclusionsThe microhardness of polymers used for intraoral prostheses decreases following thermocycling. Among specimens immersed in beverages, those immersed in cola or wine experienced the greatest decrease in microhardness. Immersion of acrylic resins in LI significantly decreased the microhardness in relation to the initial value. Among the resins assessed, QC-20 exhibited the lowest initial hardness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The properties of the hot melt adhesive pressure sensitive (HMPSA) using an elastomer as a base polymer a copolymer of styrene and butadiene (SBS) and variation of tackifiers resins such as hydrocarbon resins and hydrogenated hydrocarbon were investigated. The formulations were prepared by mixing process within shear. The adhesives prepared were evaluated in test Brookfield viscosity and softening point Ring and Ball to compare the formulations and the influence of variations in raw materials. Infrared analyzes were performed to detect the reactions between the inputs and investigate the chemical interactions of the same properties of the adhesive. In thermal analysis, the assay was performed thermogravimetry (TG) and diferencial exploratory calorimetry (DSC). Were investigated the parameters of the tensile test on each of the formulations. Finally, were analysed comparatively the basic formulations of adhesives with their respective raw materials

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The fracture surfaces express the sequence of events of energy release due to crack propagation by linking the relief of the fracture to the loading stresses. This study aims to evaluate the heterogeneity of the critical zone for the advancement of the crack along its entire length in a thermoset composite carbon fiber and epoxy matrix, fractured in DCB testing (Double Cantilever Beam) and ENF (End-Notched Flexure). Investigations were made from image stacks obtained by optical reflection of extended depth from focus reconstruction. The program NIH Image J was used to obtain elevation map and fully focused images of the fracture surface, whose topographies were quantitatively analyzed. The monofractal behavior for DCB samples was assessed as being heterogeneous along the crack front and along the crack for all the conditionings. For the samples fractured in ENF test, there was a strong positive correlation to the natural condition, considering the fibers at 0° for the monofractal dimension and structural dimension (Df and Ds). For fibers at 90° to crack propagation, there was a moderate positive correlation for the textural dimension of natural condition. However, for the samples under ultraviolet condition and those subjected to thermal cycles, there was no correlation between the fractal dimension and fracture toughness in mode II

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The glassy carbon is a material with a huge technological evolution. Due to its lightness, biocompatibility and their thermal and electrical properties this material finds applications in several industrial fields such as electronics, medical, aerospace and chemical. In order to explore the conductive properties of glassy carbon for use as modified electrodes, the present work aims the processing of monolithic and reticulated glassy carbon with colloidal copper for use in electrochemical applications. First, the best parameters for the cure of furfuryl alcohol resin doped were established through viscosimetry measurements and pressurized differential scanning calorimetry. The analysis of the micrographs of the cured resins show that copper concentrations above 3% weight, generate higher porosity in the material. The characterizations of the monolithic and reticulated glassy carbon resulting from carbonization were performed by scanning electron microscopy (SEM), Raman and Electrochemical impedance spectroscopy, and although it was not possible to detect the presence of copper by SEM, the influence of these particles have been observed by Raman and FT-IR spectra and electrochemical behavior of the material. The decrease in conductivity of monolithic and reticulated glassy carbon in the presence of copper may be related to the defects caused by the presence of copper in the structure of the material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Studies on new adhesives and resins for bonding wood and wood products are being conducted with the intention of improving their properties, taking into account a lower environmental impact. For this reason new formulations of polyvinyl acetate (PVA) adhesives have been developed, because they have no chemicals in its composition extremely polluting and harmful to health, as is the case of formaldehyde-based resins, which in turn are the most commonly used today for wood panels production. This study tested three different formulations of PVA adhesives, with different times and temperatures of pressing for the production of Eucalyptus sp. Plywood, coming up in satisfactory results with respect to shear strength at the bondline, which was higher for the PVA adhesives compared with urea-formaldehyde and phenol. The results of MOE and MOR were lower than those values of the panels produced with urea and phenol-formaldehyde, and the results of physical tests showed to be close to the panels produced with these same adhesives

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The competitiveness among global markets, the constant need for reducing manufacturing costs and also the growing environmental commitments are fueling the development of techniques for recovery residual parts generated by industrial processes. Among the various areas of a company, we highlight those that involve the processing of raw materials derived from oil, such as polymers (resins), which may take centuries to decompose in the environment and also present as a economic and environmentally strategic point. Thus, this study would examine the recovery of waste polypropylene, from the injection process of a major multinational in the field of home appliances through the recycling by a process comprising the milling, extrusion and chipping of waste material. Easy to deploy, this proposal aims to reduce levels negligible disposal (scrap) of these residues as well as the reintegration of the production process into pieces no visual and no structural importance, aimed at cutting costs and reducing environmental impacts caused. After the survey data in kilograms of waste material generated in a given period of time, and the study of changes in material properties, it would enable the reuse steadily in the injection process