973 resultados para Sweetener and dental caries


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Masseter muscle hypertrophy is characterized by unilateral or bilateral enlargement of the masseter muscles affecting both males and females after puberty. Its etiology remains unknown. Limitations on mouth opening and also tension in the region of the hypertrophied muscle are symptoms reported. This paper reports a case of masseter muscle hypertrophy diagnosed using imaging modalities such as conventional radiography, computed tomography and magnetic resonance imaging scans. The familiarity with this condition is important to settle the differential diagnosis with other pathologies such as parotid gland tumors and dental infection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fracture of dentures is a common clinical finding in daily prosthodontic practice, resulting in great inconvenience to both patient and dentist. A satisfactory repair should be cost-effective, simple to perform, and quick; it should also match the original color and not cause distortion to the existing denture. Different repair materials, surface designs, and mechanical and chemical surface treatments have been recommended in order to obtain stronger repairs. This article reviews some of the available literature with regard to the most important factors that may influence the strength of denture repairs. © 2007 by The American College of Prosthodontists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the clinical courses of three cases with extra-oral sinus tract formation, from diagnosis and treatment to short-term follow-up and evaluation. All teeth involved had periradicular radiolucent areas noted on radiographic examination and extra-oral sinus tracts appearing on the chin with exudation and unpleasant aesthetic appearance. The adopted treatment protocol included treating the sinus tract surface simultaneously with the root canal therapy. After root canal shaping using 5.25% sodium hypochlorite solution, calcium hydroxide-based pastes associated with different vehicles were inserted into the root canal for 4 months, and were changed monthly. All the sinus tracts healed in 7 to 10 days. The apical lesions were completely repaired in a maximum period of 24 months. The treatment adopted provided a complete healing of the periapical lesions in a short follow-up period. Surgical repair of the cutaneous sinus tract was therefore unnecessary. © 2007 The Authors. Journal compilation © 2007 Australian Society of Endodontology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the microtensile bond strength of a repair composite resin to a leucite-reinforced feldspathic ceramic (Omega 900, VITA) submitted to two surface conditionings methods: 1) etching with hydrofluoric acid + silane application or 2) tribochemical silica coating. The null hypothesis is that both surface treatments can generate similar bond strengths. Ten ceramic blocks (6x6x6 mm) were fabricated and randomly assigned to 2 groups (n=5), according to the conditioning method: G1- 10% hydrofluoric acid application for 2 min plus rinsing and drying, followed by silane application for 30 s; G2- airborne particle abrasion with 30 μm silica oxide particles (CoJet-Sand) for 20 s using a chairside air-abrasion device (CoJet System), followed by silane application for 5 min. Single Bond adhesive system was applied to the surfaces and light cured (40 s). Z-250 composite resin was placed incrementally on the treated ceramic surface to build a 6x6x6 mm block. Bar specimens with an adhesive area of approximately 1 ± 0.1 mm2 were obtained from the composite-ceramic blocks (6 per block and 30 per group) for microtensile testing. No statistically significant difference was observed between G1 (10.19 ± 3.1 MPa) and G2 (10.17 ± 3.1 MPa) (p=0.982) (Student's t test; á = 0.05). The null hypothesis was, therefore, accepted. In conclusion, both surface conditioning methods provided similar microtensile bond strengths between the repair composite resin and the ceramic. Further studies using long-term aging procedures should be conducted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alginate or irreversible hydrocolloid is one the most accepted and frequently employed impression materials in dental practice. Substances like zinc, cadmium, lead silicate and fluorides, which are included in several alginate brands with the aim of improving their physical, chemical and mechanical properties, are a source of serious concern as regards their toxicity. Some brands of alginate have been reported to contain potentially toxic fluorides and metals such as cadmium, lead and zinc silicates, either singly or combined. Consequently, special care should be taken while preparing of these materials. It is necessary to monitor potentially toxic chemicals and metals in the alginates continually to avoid contamination of dental professionals and patients. In this review, alginates used in dentistry are analyzed for potential toxicity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study evaluated the effectiveness of different exposure times of microwave irradiation on the disinfection of a hard chairside reline resin. Materials and Methods: Sterile specimens were individually inoculated with one of the tested microorganisms (Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans, and Bacillus subtilis) and incubated for 24 hours at 37°C. For each microorganism, 10 specimens were not microwaved (control), and 50 specimens were microwaved. Control specimens were individually immersed in sterile saline, and replicate aliquots of serial dilutions were plated on selective media appropriate for each organism. Irradiated specimens were immersed in water and microwaved at 650 W for 1, 2, 3, 4, or 5 minutes before serial dilutions and platings. After 48 hours of incubation, colonies on plates were counted. Irradiated specimens were also incubated for 7 days. Some specimens were prepared for scanning electron microscopic (SEM) analysis. Results: Specimens irradiated for 3, 4, and 5 minutes showed sterilization. After 2 minutes of irradiation, specimens inoculated with C. albicans were sterilized, whereas those inoculated with bacteria were disinfected. One minute of irradiation resulted in growth of all microorganisms. SEM examination indicated alteration in cell morphology of sterilized specimens. The effectiveness of microwave irradiation was improved as the exposure time increased. Conclusion: This study suggests that 3 minutes of microwave irradiation can be used for acrylic resin sterilization, thus preventing cross-contamination. © 2008 by The American College of Prosthodontists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study evaluated the influence of surface abrasion of transfer copings to obtain a precise master cast for a partially edentulous restoration with different inclinations. Materials and Methods: Replicas (N = 30) of a metal matrix (control group) containing two implants at 90° and 65° in relation to the benchtop were obtained using a polyether impression material and three impression techniques: square impression copings splint with dental floss and autopolymerizing acrylic resin (TRS), square impression copings abraded with aluminum oxide (TA), and square impression copings abraded with aluminum oxide and adhesive-coated (TAA). The replicas obtained in type V stone were digitalized, and the images were exported to AutoCAD software to perform the readings of possible degree alterations in implant inclinations. The results were submitted to analysis of variance (ANOVA) and Tukey test (α < 0.05). Results: Comparing the techniques with regard to the 90° implant inclination, no statistical difference was observed between the three techniques and the control group. Analyzing the three techniques with regard to the 65° implant inclination, no significant difference was seen between technique TA and the control group. Conclusions: Technique TA presented more accurate master casts than TRS and TAA techniques. The angulated implant (65°) tended to generate more imprecise master casts than implants perpendicular to the surface. © 2008 by The American College of Prosthodontists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Orthodontics has always used lateral cephalometric radiographs (LC) as the main examination in the orthodontic diagnosis and treatment plan. The determination of incisor position is part of most cephalometric analysis, including Tweed analysis. However, all radiographic images have limitations, since it is a bidimensional image of a tridimensional structure and overlapping of bone and dental structures often occurs. Computed tomography (CT) allows a trustworthy diagnostic, mainly for its tridimensional images possibility. In this situation it seems reasonable to question the classic cephalometric analysis, creating factors of comparison with computed tomography data. Aim: For this, it was considered the evaluation of the angle between the long axis of the inferior incisor and the mandibular plane (IMPA) in the lateral cephalograph and in the computed tomography. Methods: Nineteen patients, selected for orthodontic treatment, had constituted the sample of this study, 12 female and 7 male, with ages between 16 years and 4 months and 28 years and 2 months. After the collection of data made by two examiners, statistical analyses for the attainment of the errors intra and inter-examiners had been made, using level of significance of 5%. Results and Conclusion: It was concluded that IMPA can be measured in the lateral cephalometric radiographs with trustworthiness, even that its values were smaller when compared with the computed tomography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The technique presented in this article presents a protocol for treatment that reduces the time required for the fabrication and placement of an implant supported prosthesis. It also offers improved patient comfort at a lower cost when compared to conventional technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This aim of this study was to investigate the biocompatibility of two experimental acetazolamide (AZ)-based pastes in the subcutaneous tissue of rats. Both pastes contained AZ as the main component in similar concentration. The vehicle in experimental paste 1 was saline, while experimental paste 2 was prepared with propylene glycol. Sixty polyethylene tubes were sealed at one end with gutta-percha (GP), which served as a control. Half of the tubes were flled with paste 1 and half with paste 2. The tubes were implanted in the subcutaneous tissue of 15 rats, being 4 tubes for each animal. The animals were killed 7, 15 and 45 days after surgery and the specimens were processed in laboratory. The histological sections were stained with hematoxylin and eosin and were analyzed by light microscopy. Scores were assigned to level of infammatory process: 1- none; 2- mild; 3- moderate; 4- severe. The data were analyzed statistically by the Kruskal-Wallis test (p≤0.05). Paste 1 produced an infammatory process at 7 days. However, the intensity of this infammation decreased with time and was nearly absent at 45 days. No statistically signifcant difference (p>0.05) was observed between the control (GP) and paste 1. However, paste 2 produced infammatory response at all study periods and differed signifcantly (p<0.05) from the control. In conclusion, in the present study, the experimental AZ-based paste 1 was considered as biocompatible as the control matrial (GP), while experimental paste 2 was irritating to rat subcutaneous tissue.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the biosecurity measures adopted in dental prosthesis laboratories of the city of João Pessoa, PB, Brazil with respect to prosthetic works sent by dentists. Method: Twenty-five dental prosthesis technicians (DPT) of the city of João Pessoa, PB, filled out a questionnaire referring to their knowledge of the biosecurity principles, disinfection of impressions and other prosthetic items, and the use of individual protection equipment (IPE). Results: Although 92% of the interviewees believed in the possible occurrence of cross-infection between dental prosthesis laboratories and dental offices, 64% declared that the prosthetic works received in their laboratories do not undergo any disinfection procedure. It was also observed that, for disinfection of impressions and stone casts, the chemical substances are not used as recommended by the manufacturers or are innocuous to microorganisms. Regarding the use of IPE, 60% of the DPT used mask, but only 4% used gowns. With respect to the measures taken regarding the impressions received from dental offices, 56% of the interviewees only wash them in running tap water, and 56% of the stone casts that arrive at the laboratory are not disinfected in any way. Conclusion: There is a need for more motivation and instructions to DPT regarding the prevention of cross-contamination during sending and receiving of prosthetic works between dental prosthesis laboratories and dental offices because the DPT evaluated in this study were found negligent with respect to disinfection procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study compared the color fidelity of different composite resins with their registration in the Vita Classical Shade Guide. Using a prefabricated Teflon mold, 120 specimens were divided into four groups fn - 30), according to the resin tested. Three subgroups (a = 10) were prepared for each resin group; these subgroups tested enamel shade, dentin shade, and enamel and dentin shade. Three measurements were performed to verily whether the tooth shade matched that of the Vita Classical Shade Guide. The color was evaluated and the shade variations were calculated. The data were submitted to a three-way AN OVA test (time, color match, and composite type), followed by Tukey's test. It was concluded that all composite resins showed color differences in relation to the Vita Classical Shade Guide.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the intraexaminer reproducibility of static anthropometric measurements of undergraduate dental students as well as the characteristics and regulating measurements of the dental stools used by them. Methods: Forty volunteers and 6 types of dental stools were evaluated. For the anthropometric measurements the employed equipments were: an adapted office chair, aflexible measuring tape with two adapted rods, a metallic device with a 90 degree central angle, string, a 35 x 24 cm rectangular wooden board, isolating tape and crepe tape. In order to standardize the position of the adapted office chair and the volunteers' feet, the floor was marked with the isolating and crepe tapes. A string was attached to the waist of each volunteer to mark the area corresponding to the kidney region making it possible to measure the seat-renal region area. The examined anthropometric measurements were height, trunkcephalic heigh, sacral-popliteal distance (OK?), hip width, popliteal height and the seat-renal region height. The evaluated characteristics of the dental stools relative to the seat were depth, horizontal width and minimum/maximum height. The back of the dental stool was evaluated as for the minimum/ maximum height adjustment. The anthropometric and dental stool measurements were obtained by a single examiner at two moments with a 1-week interval between the evaluations. Intra-class correlation coefficient (ρ) was used to estimate the intraexaminer reproducibility. Results: Excellent reproducibility was observed for all anthropometric measurements obtained (ρ=0.99) as well as for all dental stools evaluated (ρ=0.99). Conclusion: The method used to obtain the anthropometric and dental stools measurements was reproducible and can be used reliably.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the microbial contamination in samples of radiographic developing and fixing solutions, radiographic processing water, dental unit waterlines and dental office's external water supply. Methods: Samples of 50 private dental offices and 20 dental offices of the School of Dentistry de Araçatuba-UNESP were collected. The samples were subjected to neutralization of the residual inhibitory agents followed by pre-enrichment in peptone water and EVA broth and were inoculated in selective and non-selective culture media. The DNA of the samples was extracted and the presence of superinfectant microorganisms was evaluated by PCR. The differences in the prevalence of the microorganisms in the samples of the solutions were analyzed by repeated-measures analysis of variance for category data, while the Chi-Square and Mann-Whitney tests were used to evaluate the existence of associations between the total number of heterotrophic microorganisms and infection control protocols. The significance level was set at 5%. Results: Samples of radiographic fixing solution presented a remarkably less frequent contamination than radiographic developing solution and radiographic processing water. The latter exhibited microorganisms typically originated from the oral microbiota and human skin as well as microorganisms frequently found in dental unit waterlines. There was less contamination of radiographic processing water in the dental offices where the x-ray film packets were disinfected before processing or were covered by a plastic film. Additionally, all samples of dental office's external water supply were drinkable. Conclusion: Covering the x-ray film packets with a plastic film protection barrier was proven the best manner to reduce the contamination of the evaluated solutions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)