975 resultados para Star sigma-compact


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context Steroidogenic acute regulatory protein (StAR) is crucial for transport of cholesterol to mitochondria where biosynthesis of steroids is initiated. Loss of StAR function causes lipoid congenital adrenal hyperplasia (LCAH). Objective StAR gene mutations causing partial loss of function manifest atypical and may be mistaken as familial glucocorticoid deficiency. Only a few mutations have been reported. Design To report clinical, biochemical, genetic, protein structure and functional data on two novel StAR mutations, and to compare them with published literature. Setting Collaboration between the University Children's Hospital Bern, Switzerland, and the CIBERER, Hospital Vall d'Hebron, Autonomous University, Barcelona, Spain. Patients Two subjects of a non-consanguineous Caucasian family were studied. The 46,XX phenotypic normal female was diagnosed with adrenal insufficiency at the age of 10 months, had normal pubertal development and still has no signs of hypergonodatropic hypogonadism at 32 years of age. Her 46,XY brother was born with normal male external genitalia and was diagnosed with adrenal insufficiency at 14 months. Puberty was normal and no signs of hypergonadotropic hypogonadism are present at 29 years of age. Results StAR gene analysis revealed two novel compound heterozygote mutations T44HfsX3 and G221S. T44HfsX3 is a loss-of-function StAR mutation. G221S retains partial activity (~30%) and is therefore responsible for a milder, non-classic phenotype. G221S is located in the cholesterol binding pocket and seems to alter binding/release of cholesterol. Conclusions StAR mutations located in the cholesterol binding pocket (V187M, R188C, R192C, G221D/S) seem to cause non-classic lipoid CAH. Accuracy of genotype-phenotype prediction by in vitro testing may vary with the assays employed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes the authors' currently favored method of nipple reconstruction in cases of a pre-existing scar on the breast mound that passes through the intended site of nipple reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A systematic analysis of New Physics impacts on the rare decays KL→π0ell+ell- is performed. Thanks to their different sensitivities to flavor-changing local effective interactions, these two modes could provide valuable information on the nature of the possible New Physics at play. In particular, a combined measurement of both modes could disentangle scalar/pseudoscalar from vector or axial-vector contributions. For the latter, model-independent bounds are derived. Finally, the KL→π0μ+μ- forward-backward CP-asymmetry is considered, and shown to give interesting complementary information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Excitatory neurons at the level of cortical layer 4 in the rodent somatosensory barrel field often display a strong eccentricity in comparison with layer 4 neurons in other cortical regions. In rat, dendritic symmetry of the 2 main excitatory neuronal classes, spiny stellate and star pyramid neurons (SSNs and SPNs), was quantified by an asymmetry index, the dendrite-free angle. We carefully measured shrinkage and analyzed its influence on morphological parameters. SSNs had mostly eccentric morphology, whereas SPNs were nearly radially symmetric. Most asymmetric neurons were located near the barrel border. The axonal projections, analyzed at the level of layer 4, were mostly restricted to a single barrel except for those of 3 interbarrel projection neurons. Comparing voxel representations of dendrites and axon collaterals of the same neuron revealed a close overlap of dendritic and axonal fields, more pronounced in SSNs versus SPNs and considerably stronger in spiny L4 neurons versus extragranular pyramidal cells. These observations suggest that within a barrel dendrites and axons of individual excitatory cells are organized in subcolumns that may confer receptive field properties such as directional selectivity to higher layers, whereas the interbarrel projections challenge our view of barrels as completely independent processors of thalamic input.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONCLUSIONS: Speech understanding is better with the Baha Divino than with the Baha Compact in competing noise from the rear. No difference was found for speech understanding in quiet. Subjectively, overall sound quality and speech understanding were rated better for the Baha Divino. OBJECTIVES: To compare speech understanding in quiet and in noise and subjective ratings for two different bone-anchored hearing aids: the recently developed Baha Divino and the Baha Compact. PATIENTS AND METHODS: Seven adults with bilateral conductive or mixed hearing losses who were users of a bone-anchored hearing aid were tested with the Baha Compact in quiet and in noise. Tests were repeated after 3 months of use with the Baha Divino. RESULTS: There was no significant difference between the two types of Baha for speech understanding in quiet when tested with German numbers and monosyllabic words at presentation levels between 50 and 80 dB. For speech understanding in noise, an advantage of 2.3 dB for the Baha Divino vs the Baha Compact was found, if noise was emitted from a loudspeaker to the rear of the listener and the directional microphone noise reduction system was activated. Subjectively, the Baha Divino was rated statistically significantly better in terms of overall sound quality.