991 resultados para Similarity measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The movement of the circular piston in an oscillating piston positive displacement flowmeter is important in understanding the operation of the flowmeter, and the leakage of liquid past the piston plays a key role in the performance of the meter. The clearances between the piston and the chamber are small, typically less than 60 νm. In order to measure this film thickness a fluorescent dye was added to the water passing through the meter, which was illuminated with UV light. Visible light images were captured with a digital camera and analysed to give a measure of the film thickness with an uncertainty of less than 7%. It is known that this method lacks precision unless careful calibration is undertaken. Methods to achieve this are discussed in the paper. The grey level values for a range of film thicknesses were calibrated in situ with six dye concentrations to select the most appropriate one for the range of liquid film thickness. Data obtained for the oscillating piston flowmeter demonstrate the value of the fluorescence technique. The method is useful, inexpensive and straightforward and can be extended to other applications where measurement of liquid film thickness is required. © 2011 IOP Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new theoretical model that predicts the magnetostriction of multilayered composites has been developed. The model takes into account the shear stress between the composite layers and consequently predicts a non-uniform strain along their thickness. The model has been experimentally validated by producing composites formed from three materials with different magnetostrains and mechanical properties, and controlled layer thicknesses in the order of micrometers. Deformations of several ppm, up to 7.5% of the saturation magnetostrain were measured between the edge and the centre of such composites. © 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When a thin rectangular plate is restrained on the two long edges and free on the remaining edges, the equivalent stiffness of the restraining joints can be identified by the order of the natural frequencies obtained using the free response of the plate at a single location. This work presents a method to identify the equivalent stiffness of the restraining joints, being represented as simply supporting the plate but elastically restraining it in rotation. An integral transform is used to map the autospectrum of the free response from the frequency domain to the stiffness domain in order to identify the equivalent torsional stiffness of the restrained edges of the plate and also the order of natural frequencies. The kernel of the integral transform is built interpolating data from a finite element model of the plate. The method introduced in this paper can also be applied to plates or shells with different shapes and boundary conditions. © 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter presents data from triaxial tests conducted as part of a research programme into the stress-strain behaviour of clays and silts at Cambridge University. To support findings from earlier research using databases of soil tests, eighteen CIU triaxial tests on speswhite kaolin were performed to confirm an assumed link between mobilisation strain (γ M=2) and overconsolidation ratio (OCR). In the moderate shear stress range (0.2c u to 0.8c u) the test data are essentially linear on log-log plots. Both the slopes and intercepts of these lines are simple functions of OCR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current state-of-the-art techniques for determination of the change in volume of human chests, used in lung-function measurement, calculate the volume bounded by a reconstructed chest surface and its projection on to an approximately parallel static plane over a series of time instants. This method works well so long as the subject does not move globally relative to the reconstructed surface's co-ordinate system. In practice this means the subject has to be braced, which restricts the technique's use. We present here a method to compensate for global motion of the subject, allowing accurate measurement while free-standing, and also while undergoing intentional motion. © 2012 Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Active vibration control (AVC) is a relatively new technology for the mitigation of annoying human-induced vibrations in floors. However, recent technological developments have demonstrated its great potential application in this field. Despite this, when a floor is found to have problematic floor vibrations after construction the unfamiliar technology of AVC is usually avoided in favour of more common techniques, such as Tuned Mass Dampers (TMDs) which have a proven track record of successful application, particularly for footbridges and staircases. This study aims to investigate the advantages and disadvantages that AVC has, when compared with TMDs, for the application of mitigation of pedestrian-induced floor vibrations in offices. Simulations are performed using the results from a finite element model of a typical office layout that has a high vibration response level. The vibration problems on this floor are then alleviated through the use of both AVC and TMDs and the results of each mitigation configuration compared. The results of this study will enable a more informed decision to be made by building owners and structural engineers regarding suitable technologies for reducing floor vibrations.