951 resultados para Quantitative-evaluation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. Chronic rhinosinusitis (CRS) is a risk factor for asthma exacerbations and is associated with greater clinical severity. Discrepancies may exist between CRS clinical diagnosis and data from paranasal sinus (PS) X-ray or computed tomography (CT) scans. The objective was to compare PS involvement using low-dose CT and plain X-ray in allergic asthmatic patients with rhinitis. Methods. Patients underwent PS radiography in the frontal and mentonian positions and low-dose CT consisting of six to eight coronal scans performed on the central region of the sphenoidal, ethmoidal, maxillary, and frontal sinuses. Possible results for each sinus were a normal aspect or the presence of mucosal thickening, opacification, and/or air-fluid level. Results. Eighty-five (93.4%) of 91 study patients had radiological changes on radiography or CT. In only six (6.6%) were both tests normal. The maxillary was the most involved sinus by both methods. Simultaneous PS abnormalities were observed in 40.5% on X-ray and 56.7% on CT. For the frontal, ethmoidal, and sphenoidal sinuses, the proportion of normal results differed significantly between X-ray and CT: 80.2% versus 89%, 76.9% versus 63.7% and 96.7% versus 70.3%, respectively (p <.05). Agreement was over 70% for the maxillary and frontal sinuses. CT also provided a better diagnosis of air-fluid level changes than X-ray. Conclusions. Low-dose CT significantly showed larger number of normal PS results and diagnosed more severe PS lesions. As the determination of true sinus severity lesion impacts in asthma control, low-dose CT may replace PS plain X-ray and conventional CT to support better clinical decisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare videofluoroscopy swallowing study (VFSS) with the fiberoptic endoscopic evaluation of swallowing (FEES) in children and to determine the accuracy of FEES in the diagnosis of specific swallowing disorders. STUDY DESIGN: Cross-sectional study. SETTING: Hospital da Crianca Santo Antonio, affiliated with Santa Casa de Misericordia Hospital Complex, Porto Alegre, RS, Brazil. SUBJECTS AND METHODS: FEES findings were compared to those of VFSS in 30 children. Kappa coefficients for interobserver agreement were calculated. Thereafter, these coefficients were evaluated in terms of agreement between FEES and VFSS. In addition, the sensitivity, specificity, positive predictive value, and negative predictive value of FEES were calculated for four swallowing parameters (posterior spillover, pharyngeal residues, laryngeal penetration, and laryngotracheal aspiration). RESULTS: Interobserver agreement rates greater than 70 percent were obtained for all FEES parameters analyzed, except for pharyngeal residues with puree consistency (agreement = 66.7%, K = 0.296, P = 0.091). Laryngeal aspiration and penetration yielded the best level of agreement (100%, K = 1) for the laryngeal aspiration of puree residues. CONCLUSION: The diagnostic agreement between FEES (both observers) and VFSS was low. Regarding the analyzed parameters, laryngeal penetration and aspiration yielded the highest interobserver agreement in terms of FEES, and also showed the highest specificity and positive predictive value when compared to VFSS. (C) 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background It is noteworthy that there is a clear clinical, epidemiological and pathophysiological association between upper and lower airway inflammation in rhinitis and asthma. Objective The aim of this study was to compare the eosinophil counts in induced sputum and nasal lavage fluids in asthma, checking their association and the accuracy of nasal eosinophilia as a predictor of sputum eosinophilia by a cross-sectional study. Methods The clinical evaluation, asthma control questionnaire (ACQ), pre- and post-bronchodilator spirometry, nasal and sputum sample was performed. The nasal eosinophilia was analysed by a receiver operating curve and logistic regression model. Results In 140 adults, the post-bronchodilator forced expiratory volume in 1 s (FEV(1)) did not differ between patients with or without sputum eosinophilia (0.18). After adjusted for upper airway symptoms, age, ACQ score and post-bronchodilator FEV(1), sputum eosinophilia was associated with 52 times increase in odds of nasal eosinophilia, whereas each 1% increase in bronchodilator response was associated with 7% increase in odds of nasal eosinophilia. Conclusion This study brings further evidence that upper airway diseases are an important component of the asthma syndrome. Furthermore, monitoring of nasal eosinophilia by quantitative cytology may be useful as a surrogate of sputum cytology in as a component of composite measurement for determining airway inflammation.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Heart transplantation (OHT) has traditionally been contraindicated in the presence of severe pulmonary hypertension (PH), as detected by right heart catheterization. Noninvasive methods are still not reliably accurate to make this evaluation. Objectives. Determine the efficacy of echo Doppler analysis for the diagnosis of severe PH. Methods. One hundred thirty patients (mean age = 42 +/- 15 years, 82 men) showed severe left ventricular dysfunction (mean ejection fraction = 29 +/- 12%; functional class III-IV). We excluded patients with atrial fibrillation, heart failure secondary to congenital disease, and valvulopathy. The pulmonary parameters defined as severe PH were: systolic pulmonary artery pressure (sPAP) >= 60 mm Hg; a mean transpulmonary gradient >= 15; or pulmonary vascular resistance >= 5 Wood units. Patients underwent a right heart catheterization using a Swan-Ganz catheter to measure hemodynamic parameters and to noninvasively estimate right-sided pressures from spectral Doppler recordings of tricuspid regurgitation velocity (right ventricular systolic pressure [RVsP]). A Pearson correlation of sPAP was obtained with RVsP by; the sensitivity of RVsP for the diagnosis of PH was determined by a receiver operating characteristic (ROC) curve. Results. A good correlation between sPAP and RVsP was obtained by Pearson correlation analysis (r = 0.64; 95% confidence interval [CI] 0.50-0.75; P < .001). The ROC curve analysis showed a sensitivity of 100%, a specificity of 37.2%, (95% CI 0.69-0.83, P < .0001) of a RVsP < 45 mm Hg (cutoff) on the exclusion of severe PH. Conclusions. The cutoff of RVsP < 45 mm Hg, on noninvasive echo Doppler evaluation of PH is an efficient method to replace invasive heart catheterization in OHT candidates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Orthotopic heart transplantation renders the recipient denervated. This remodeling of the intrinsic cardiac nervous system should be taken in account during functional evaluation for allograft coronary artery disease. Dobutamine stress echocardiography (DSE) has been used to detect patients at greater risk. The aim of this study was to determine whether patients with various autonomic response levels, and supposed reinnervation patterns, show the same response to DSE. Methods. We studied 20 patients who had survived more than 5 years after orthotopic heart transplantation. All patients underwent a Holter evaluation. We considered patients with low variability to be those with less than a 40-bpm variation from the lowest to highest heart rate, so-called ""noninnenervated"" (group NI). Patients who had 40-bpm or more variation were considered to show high variability and called ""reinnervated"" (group RI). After that, all patients performed an ergometric test and DSE. Results. Groups were defined as NI (n = 9) and RI (n = 11). Ergometric tests confirmed this response with NI patients showing less variability when compared to RI patients (P = .0401). During DSE, patients showed similar median heart rate responses according to the dobutamine dose. Spearmen correlation showed r = 1.0 (P = .016). Conclusions: DES was effective to reach higher heart rates, probably related to catecholamine infusion. These findings may justify a better response when evaluating cardiac allograft vasculopathy in heart transplant patients.