975 resultados para Pulse generators
Resumo:
OBJECTIVE: Research regarding communication between pediatricians and parents in pediatric consultation has mainly focused on parental satisfaction, on its influence on compliance and on communication techniques used by pediatricians. However, there is paucity in research regarding parental stress levels during pediatric consultation. Therefore, the aim of our study was to measure parental heart rate variability related as a measure of stress levels during pediatric consultation. METHODS: Video recordings with simultaneous monitoring and recording of parental heart rate were obtained from 38 pediatric consultations in the ambulatory or hospital setting of the department of pediatrics (HFR, Fribourg, Switzerland). Pulse variation was measured every 5 seconds and heart rate variability (increase or decrease were analyzed) in relation to various sections of the consultation. RESULTS: Heart rate significantly decreased at the end of the consultation compared to the beginning of the consultation (p= 0.0567). In addition, heart rate significantly decreased at the beginning of clinical examination (p= 0.0476) compared to psychosocial history taking. During the discussion of laboratory findings and diagnosis, heart rate was significantly elevated compared to the discussion of the prognosis (p=0.0505). CONCLUSION: We conclude that pediatric consultation has a significant impact on parental stress levels shown by parental heart variability. In general, it can be shown that stress levels significantly decrease at the end of the consultation compared to the beginning of the consultation. In addition, stress levels decrease at the beginning of clinical examination and increase during psychosocial history taking and discussion of laboratory findings and diagnosis. Therefore, our findings highlight the importance of a thorough consultation which include a comprehensive clinical examination with special care taken regarding psychosocial issues and information given regarding the diagnosis.
Resumo:
Functional imaging with intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) is demonstrated. Images were acquired at 3 Tesla using a standard Stejskal-Tanner diffusion-weighted echo-planar imaging sequence with multiple b-values. Cerebro-spinal fluid signal, which is highly incoherent, was suppressed with an inversion recovery preparation pulse. IVIM microvascular perfusion parameters were calculated according to a two-compartment (vascular and non-vascular) diffusion model. The results obtained in 8 healthy human volunteers during visual stimulation are presented. The IVIM blood flow related parameter fD* increased 170% during stimulation in the visual cortex, and 70% in the underlying white matter.
Resumo:
PURPOSE: Visualization of coronary blood flow by means of a slice-selective inversion pre-pulse in concert with bright-blood coronary MRA. MATERIALS AND METHODS: Coronary magnetic resonance angiography (MRA) of the right coronary artery (RCA) was performed in eight healthy adult subjects on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Medical Systems, Best, NL) using a free-breathing navigator-gated and cardiac-triggered 3D steady-state free-precession (SSFP) sequence with radial k-space sampling. Imaging was performed with and without a slice-selective inversion pre-pulse, which was positioned along the main axis of the coronary artery but perpendicular to the imaging volume. Objective image quality parameters such as SNR, CNR, maximal visible vessel length, and vessel border definition were analyzed. RESULTS: In contrast to conventional bright-blood 3D coronary MRA, the selective inversion pre-pulse provided a direct measure of coronary blood flow. In addition, CNR between the RCA and right ventricular blood pool was increased and the vessels had a tendency towards better delineation. Blood SNR and CNR between right coronary blood and epicardial fat were comparable in both sequences. CONCLUSION: The combination of a free-breathing navigator-gated and cardiac-triggered 3D SSFP sequence with a slice-selective inversion pre-pulse allows for direct and directional visualization of coronary blood flow with the additional benefit of improved contrast between coronary and right ventricular blood pool.
Resumo:
Strategies to construct the physical map of the Trypanosoma cruzi nuclear genome have to capitalize on three main advantages of the parasite genome, namely (a) its small size, (b) the fact that all chromosomes can be defined, and many of them can be isolated by pulse field gel electrophoresis, and (c) the fact that simple Southern blots of electrophoretic karyotypes can be used to map sequence tagged sites and expressed sequence tags to chromosomal bands. A major drawback to cope with is the complexity of T. cruzi genetics, that hinders the construction of a comprehensive genetic map. As a first step towards physical mapping, we report the construction and partial characterization of a T. cruzi CL-Brener genomic library in yeast artificial chromosomes (YACs) that consists of 2,770 individual YACs with a mean insert size of 365 kb encompassing around 10 genomic equivalents. Two libraries in bacterial artificial chromosomes (BACs) have been constructed, BACI and BACII. Both libraries represent about three genome equivalents. A third BAC library (BAC III) is being constructed. YACs and BACs are invaluable tools for physical mapping. More generally, they have to be considered as a common resource for research in Chagas disease
Resumo:
Direct electrical stimulation of the colon offers a promising approach for the induction of propulsive colonic contractions by using an implantable device. The objective of this study was to assess the feasibility to induce colonic contractions using a commercially available battery-operated stimulator (maximum pulse width of 1 ms and maximum amplitude of 10 V). Three pairs of pacing electrodes were inserted into the cecal seromuscular layer of anesthetized pigs. During a first set of in vivo experiments conducted on six animals, a pacing protocol leading to cecum contractions was determined: stimulation bursts with 1 ms pulse width, 10 V amplitude (7-15 mA), 120 Hz frequency, and 30-s burst duration, repeated every 2-5 min. In a second testing phase, an evaluation of the pacing protocol was performed in four animals (120 stimulation bursts in total). By using the battery-operated stimulator, contractions of the cecum and movement of contents could be induced in 92% of all stimulations. A cecal shortening of about 30% and an average intraluminal pressure increase of 10.0 +/- 6.0 mmHg were observed.
Resumo:
Transmembrane receptor-kinases are widespread throughout eukaryotes and their activities are known to regulate all kinds of cellular responses in diverse organs and cell types. In order to guarantee the correct amplitude and duration of signals, receptor levels at the cellular surface need to be tightly controlled. The regulation of receptor degradation is the most direct way to achieve this and elaborate mechanisms are in place to control this process. Therefore, the rate of receptor degradation is a parameter of central importance for understanding the dynamics of a signal transduction cascade. Unfortunately, degradation of transmembrane receptors is a complicated multistep process that involves internalization from the plasma membrane, invagination into the lumen of endosomal compartments, and finally fusion with the vacuole for degradation by vacuolar proteases. Therefore, degradation should be measured in an as noninvasive way as possible, such as not to interfere with the complicated transport processes. Here, a method for minimally invasive, in vivo turn-over measurements in intact organs is provided. This technique was used for quantifying the turn-over rates of the Brassinosteroid receptor kinase BRI1 (BRASSINOSTEROID INSENSITIVE 1) in Arabidopsis thaliana root meristems. Pulse-chase expression of a fluorescently labeled BRI1 variant was used and its turn-over rate was determined by quantitative confocal microscopy. This method is well suited to measure turn-over of transmembrane kinases, but can evidently be extended to measure turn-over of any types of transmembrane proteins.
Resumo:
Glucose production by liver is a major physiological function, which is required to prevent development of hypoglycemia in the postprandial and fasted states. The mechanism of glucose release from hepatocytes has not been studied in detail but was assumed instead to depend on facilitated diffusion through the glucose transporter GLUT2. Here, we demonstrate that in the absence of GLUT2 no other transporter isoforms were overexpressed in liver and only marginally significant facilitated diffusion across the hepatocyte plasma membrane was detectable. However, the rate of hepatic glucose output was normal. This was evidenced by (i) the hyperglycemic response to i.p. glucagon injection; (ii) the in vivo measurement of glucose turnover rate; and (iii) the rate of release of neosynthesized glucose from isolated hepatocytes. These observations therefore indicated the existence of an alternative pathway for hepatic glucose output. Using a [14C]-pyruvate pulse-labeling protocol to quantitate neosynthesis and release of [14C]glucose, we demonstrated that this pathway was sensitive to low temperature (12 degreesC). It was not inhibited by cytochalasin B nor by the intracellular traffic inhibitors brefeldin A and monensin but was blocked by progesterone, an inhibitor of cholesterol and caveolae traffic from the endoplasmic reticulum to the plasma membrane. Our observations thus demonstrate that hepatic glucose release does not require the presence of GLUT2 nor of any plasma membrane glucose facilitative diffusion mechanism. This implies the existence of an as yet unsuspected pathway for glucose release that may be based on a membrane traffic mechanism.
Resumo:
In legal medicine, the post mortem interval (PMI) of interest covers the last 50 years. When only human skeletal remains are found, determining the PMI currently relies mostly on the experience of the forensic anthropologist, with few techniques available to help. Recently, several radiometric methods have been proposed to reveal PMI. For instance, (14)C and (90)Sr bomb pulse dating covers the last 60 years and give reliable PMI when teeth or bones are available. (232)Th series dating has also been proposed but requires a large amount of bones. In addition, (210)Pb dating is promising but is submitted to diagenesis and individual habits like smoking that must be handled carefully. Here we determine PMI on 29 cases of forensic interest using (90)Sr bomb pulse. In 12 cases, (210)Pb dating was added to narrow the PMI interval. In addition, anthropological investigations were carried out on 15 cases to confront anthropological expertise to the radiometric method. Results show that 10 of the 29 cases can be discarded as having no forensic interest (PMI>50 years) based only on the (90)Sr bomb pulse dating. For 10 other cases, the additional (210)Pb dating restricts the PMI uncertainty to a few years. In 15 cases, anthropological investigations corroborate the radiometric PMI. This study also shows that diagenesis and inter-individual difference in radionuclide uptake represent the main sources of uncertainty in the PMI determination using radiometric methods.
Resumo:
OBJECTIVE: To evaluate the impact of body position on the arterial stiffness indices provided by radial applanation tonometry in pregnant and nonpregnant women. METHODS: Twenty-four young women (18-30 years) in the third trimester of a normal pregnancy and 20 healthy nonpregnant women of the same age were enrolled. In each, applanation tonometry was carried out in the sitting and supine position. The following stiffness indices were analyzed: systolic augmentation index (sAix), sAix adjusted for heart rate (sAix@75) and diastolic augmentation index (dAix), all expressed in % of central aortic pulse pressure. RESULTS: The sAix was apparently not influenced by body position, but the transition from seated to supine was associated with a substantial decrease in heart rate. When correcting for this confounder by calculating the sAix@75, systolic augmentation was substantially lower when individuals were supine (mean ± SD: nonpregnant 3.0 ± 14.4%, pregnant 8.8 ± 9.7%) than when they were sitting (nonpregnant 5.7 ± 13.0%, pregnant 11.1 ± 83%, P = 0.005 supine vs. seated in both study groups, P > 0.2 for pregnant vs. nonpregnant). The influence of body position on the dAix went in the opposite direction (supine: nonpregnant 9.7 ± 6.6%, pregnant 4.4 ± 3.5%; seated: nonpregnant 7.7 ± 5.8%, pregnant 3.3 ± 2.4%, P < 0.00001 supine vs. seated in both study groups, P = 0.001 for pregnant vs. nonpregnant). CONCLUSION: Body position has a major impact on the pattern of central aortic pressure augmentation by reflected waves in healthy young women examined either during third trimester pregnancy or in the nonpregnant state.
Resumo:
The purpose of this study was to prospectively compare free-breathing navigator-gated cardiac-triggered three-dimensional steady-state free precession (SSFP) spin-labeling coronary magnetic resonance (MR) angiography performed by using Cartesian k-space sampling with that performed by using radial k-space sampling. A new dedicated placement of the two-dimensional selective labeling pulse and an individually adjusted labeling delay time approved by the institutional review board were used. In 14 volunteers (eight men, six women; mean age, 28.8 years) who gave informed consent, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, vessel length, and subjective image quality were investigated. Differences between groups were analyzed with nonparametric tests (Wilcoxon, Pearson chi2). Radial imaging, as compared with Cartesian imaging, resulted in a significant reduction in the severity of motion artifacts, as well as an increase in SNR (26.9 vs 12.0, P < .05) in the coronary arteries and CNR (23.1 vs 8.8, P < .05) between the coronary arteries and the myocardium. A tendency toward improved vessel sharpness and vessel length was also found with radial imaging. Radial SSFP imaging is a promising technique for spin-labeling coronary MR angiography.
Resumo:
Black-blood fast spin-echo imaging is a powerful technique for the evaluation of cardiac anatomy. To avoid fold-over artifacts, using a sufficiently large field of view in phase-encoding direction is mandatory. The related oversampling affects scanning time and respiratory chest motion artifacts are commonly observed. The excitation of a volume that exclusively includes the heart without its surrounding structures may help to improve scan efficiency and minimize motion artifacts. Therefore, and by building on previously reported inner-volume approach, the combination of a black-blood fast spin-echo sequence with a two-dimensionally selective radiofrequency pulse is proposed for selective "local excitation" small field of view imaging of the heart. This local excitation technique has been developed, implemented, and tested in phantoms and in vivo. With this method, small field of view imaging of a user-specified region in the human thorax is feasible, scanning becomes more time efficient, motion artifacts can be minimized, and additional flexibility in the choice of imaging parameters can be exploited.
Resumo:
High-field (>or=3 T) cardiac MRI is challenged by inhomogeneities of both the static magnetic field (B(0)) and the transmit radiofrequency field (B(1)+). The inhomogeneous B fields not only demand improved shimming methods but also impede the correct determination of the zero-order terms, i.e., the local resonance frequency f(0) and the radiofrequency power to generate the intended local B(1)+ field. In this work, dual echo time B(0)-map and dual flip angle B(1)+-map acquisition methods are combined to acquire multislice B(0)- and B(1)+-maps simultaneously covering the entire heart in a single breath hold of 18 heartbeats. A previously proposed excitation pulse shape dependent slice profile correction is tested and applied to reduce systematic errors of the multislice B(1)+-map. Localized higher-order shim correction values including the zero-order terms for frequency f(0) and radiofrequency power can be determined based on the acquired B(0)- and B(1)+-maps. This method has been tested in 7 healthy adult human subjects at 3 T and improved the B(0) field homogeneity (standard deviation) from 60 Hz to 35 Hz and the average B(1)+ field from 77% to 100% of the desired B(1)+ field when compared to more commonly used preparation methods.
Resumo:
We define equivariant semiprojectivity for C* -algebras equipped with actions of compact groups. We prove that the following examples are equivariantly semiprojective: A. Arbitrary finite dimensional C*-algebras with arbitrary actions of compact groups. - B. The Cuntz algebras Od and extended Cuntz algebras Ed, for finite d, with quasifree actions of compact groups. - C. The Cuntz algebra O∞ with any quasifree action of a finite group. For actions of finite groups, we prove that equivariant semiprojectivity is equiv- alent to a form of equivariant stability of generators and relations. We also prove that if G is finite, then C*(G) is graded semiprojective.
Resumo:
A major advance in our understanding of the natural history of Schistosoma haematobium-related morbidity has come through the introduction of the portable ultrasound machines for non-invasive examination of the kidneys and bladder. With the use of generators or battery packs to supply power in non-clinical field settings, and with the use of instant photography or miniaturized thermal printers to record permanent images, it is possible to examine scores of individuals in endemic communities every day. Broad-based ultrasound screening has allowed better definition of age-specific disease risks in urinary schistosomiasis. Results indicate that urinary tract abnormalities are common (18% overall prevalence) in S. haematobium transmission areas, with a 2-4% risk of either severe bladder abnormality or advanced ureteral obstruction. In longitudinal surveys, ultrasound studies have shown that praziquantel and metrifonate therapy are rapidly effective in reversing urinary tract abnormalities among children. The benefits of treating adults are less well known, but research in progress should help to define this issue. Similarly, the prognosis of specific ultrasound findings needs to be clarified, and the ease of sonographic examination will make such long-term follow-up studies feasible. In summary, the painless, quick, and reproducible ultrasound examination has become an essential tool in the study of urinary schistosomiasis.
Resumo:
Light influences sleep and alertness either indirectly through a well-characterized circadian pathway or directly through yet poorly understood mechanisms. Melanopsin (Opn4) is a retinal photopigment crucial for conveying nonvisual light information to the brain. Through extensive characterization of sleep and the electrocorticogram (ECoG) in melanopsin-deficient (Opn4(-/-)) mice under various light-dark (LD) schedules, we assessed the role of melanopsin in mediating the effects of light on sleep and ECoG activity. In control mice, a light pulse given during the habitual dark period readily induced sleep, whereas a dark pulse given during the habitual light period induced waking with pronounced theta (7-10 Hz) and gamma (40-70 Hz) activity, the ECoG correlates of alertness. In contrast, light failed to induce sleep in Opn4(-/-) mice, and the dark-pulse-induced increase in theta and gamma activity was delayed. A 24-h recording under a LD 1-hratio1-h schedule revealed that the failure to respond to light in Opn4(-/-) mice was restricted to the subjective dark period. Light induced c-Fos immunoreactivity in the suprachiasmatic nuclei (SCN) and in sleep-active ventrolateral preoptic (VLPO) neurons was importantly reduced in Opn4(-/-) mice, implicating both sleep-regulatory structures in the melanopsin-mediated effects of light. In addition to these acute light effects, Opn4(-/-) mice slept 1 h less during the 12-h light period of a LD 12ratio12 schedule owing to a lengthening of waking bouts. Despite this reduction in sleep time, ECoG delta power, a marker of sleep need, was decreased in Opn4(-/-) mice for most of the (subjective) dark period. Delta power reached after a 6-h sleep deprivation was similarly reduced in Opn4(-/-) mice. In mice, melanopsin's contribution to the direct effects of light on sleep is limited to the dark or active period, suggesting that at this circadian phase, melanopsin compensates for circadian variations in the photo sensitivity of other light-encoding pathways such as rod and cones. Our study, furthermore, demonstrates that lack of melanopsin alters sleep homeostasis. These findings call for a reevaluation of the role of light on mammalian physiology and behavior.