969 resultados para Premature ventricular contraction
Resumo:
This paper presents a novel mock circulation for the evaluation of ventricular assist devices (VADs), which is based on a hardware-in-the-loop concept. A numerical model of the human blood circulation runs in real time and computes instantaneous pressure, volume, and flow rate values. The VAD to be tested is connected to a numerical-hydraulic interface, which allows the interaction between the VAD and the numerical model of the circulation. The numerical-hydraulic interface consists of two pressure-controlled reservoirs, which apply the computed pressure values from the model to the VAD, and a flow probe to feed the resulting VAD flow rate back to the model. Experimental results are provided to show the proper interaction between a numerical model of the circulation and a mixed-flow blood pump.
Resumo:
BACKGROUND: Dogs experimentally inoculated with Angiostrongylus vasorum develop severe pulmonary parenchymal lesions and arterial thrombosis at the time of patency. HYPOTHESIS: A. vasorum-induced thrombosis results in arterial hypoxemia, pulmonary hypertension (PH), and altered cardiac morphology and function. ANIMALS: Six healthy Beagles experimentally inoculated with A. vasorum. METHODS: Thoracic radiographs and arterial blood gas analyses were performed 8 and 13 weeks postinoculation (wpi) and 9 weeks posttherapy (wpt). Echocardiography was done before and 2, 5, 8, 13 wpi and 9 wpt. Invasive pulmonary artery pressure (PAP) measurements were obtained 8 wpi. Two untreated dogs were necropsied 13 wpi and 4 treated dogs 9 wpt. RESULTS: All dogs had patent infections at 7 wpi and clinical respiratory signs at 8 wpi. Moderate hypoxemia (median PaO2 of 73 and 74 mmHg) present at 8 and 13 wpi had resolved by 9 wpt. Echocardiographically, no evidence of PH and no abnormalities in cardiac size and function were discernible at any time point. PAP invasively measured at 8 wpi was not different from that of control dogs. Severe radiographic pulmonary parenchymal and suspected thrombotic lesions at 13 wpi were corroborated by necropsy. Most histopathologic changes had resolved at 9 wpt, but focal inflammatory, thrombotic, and fibrotic changes still were present in all dogs. CONCLUSION: In experimentally infected Beagles, pulmonary and vascular changes induced by A. vasorum are reflected by marked radiographic changes and arterial hypoxemia. These did not result in PH and echocardiographic changes in cardiac size and function.
Resumo:
Previous reports prove the safety and efficacy of cardiac pacing employing a guidewire in the left ventricle as unipolar pacing electrode. We describe the use of left ventricular guidewire pacing as an alternative to conventional transvenous temporary right ventricular pacing in the context of transcatheter aortic valve implantation. © 2012 Wiley Periodicals, Inc.
Resumo:
Catheter ablation of ventricular tachycardia (VT) is effective and particularly useful in patients with frequent defibrillator interventions. Various substrate modification techniques have been described for unmappable or hemodynamically intolerable VT. Noninducibility is the most frequently used end point but is associated with significant limitations, so the optimal end point remains unclear. We hypothesized that elimination of local abnormal ventricular activities (LAVAs) during sinus rhythm or ventricular pacing would be a useful and effective end point for substrate-based VT ablation. As an adjunct to this strategy, we used a new high-density mapping catheter and frequently used epicardial mapping.
Resumo:
To evaluate aetiology profile and role of thrombophilia in patients with premature peripheral arterial obstructive disease (PAOD) in China.
Resumo:
OBJECTIVE: Current pulsatile ventricular assist devices operate asynchronous with the left ventricle in fixed-rate or fill-to-empty modes because electrocardiogram-triggered modes have been abandoned. We hypothesize that varying the ejection delay in the synchronized mode yields more precise control of hemodynamics and left ventricular loading. This allows for a refined management that may be clinically beneficial. METHODS: Eight sheep received a Thoratec paracorporeal ventricular assist device (Thoratec Corp, Pleasanton, Calif) via ventriculo-aortic cannulation. Left ventricular pressure and volume, aortic pressure, pulmonary flow, pump chamber pressure, and pump inflow and outflow were recorded. The pump was driven by a clinical pneumatic drive unit (Medos Medizintechnik AG, Stolberg, Germany) synchronously with the native R-wave. The start of pump ejection was delayed between 0% and 100% of the cardiac period in 10% increments. For each of these delays, hemodynamic variables were compared with baseline data using paired t tests. RESULTS: The location of the minimum of stroke work was observed at a delay of 10% (soon after aortic valve opening), resulting in a median of 43% reduction in stroke work compared with baseline. Maximum stroke work occurred at a median delay of 70% with a median stroke work increase of 11% above baseline. Left ventricular volume unloading expressed by end-diastolic volume was most pronounced for copulsation (delay 0%). CONCLUSIONS: The timing of pump ejection in synchronized mode yields control over left ventricular energetics and can be a method to achieve gradual reloading of a recoverable left ventricle. The traditionally suggested counterpulsation is not optimal in ventriculo-aortic cannulation when maximum unloading is desired.
Resumo:
Purpose: Mismatches between pump output and venous return in a continuous-flow ventricular assist device may elicit episodes of ventricular suction. This research describes a series of in vitro experiments to characterize the operating conditions under which the EVAHEART centrifugal blood pump (Sun Medical Technology Research Corp., Nagano, Japan) can be operated with minimal concern regarding left ventricular (LV) suction. Methods: The pump was interposed into a pneumatically driven pulsatile mock circulatory system (MCS) in the ventricular apex to aorta configuration. Under varying conditions of preload, afterload, and systolic pressure, the speed of the pump was increased step-wise until suction was observed. Identification of suction was based on pump inlet pressure. Results: In the case of reduced LV systolic pressure, reduced preload (=10 mmHg), and afterload (=60 mmHg), suction was observed for speeds =2,200 rpm. However, suction did not occur at any speed (up to a maximum speed of 2,400 rpm) when preload was kept within 10-14 mmHg and afterload =80 mmHg. Although in vitro experiments cannot replace in vivo models, the results indicated that ventricular suction can be avoided if sufficient preload and afterload are maintained. Conclusion: Conditions of hypovolemia and/or hypotension may increase the risk of suction at the highest speeds, irrespective of the native ventricular systolic pressure. However, in vitro guidelines are not directly transferrable to the clinical situation; therefore, patient-specific evaluation is recommended, which can be aided by ultrasonography at various points in the course of support.
Resumo:
Distal oesophageal spasm is a rare and under-investigated motility abnormality. Recent studies indicate effective bolus transit in varying percentages of distal oesophageal spasm patients.