990 resultados para Power signal
Resumo:
A mathematical model of the voltage drop which arises in on-chip power distribution networks is used to compare the maximum voltage drop in the case of different geometric arrangements of the pads supplying power to the chip. These include the square or Manhattan power pad arrangement, which currently predominates, as well as equilateral triangular and hexagonal arrangements. In agreement with the findings in the literature and with physical and SPICE models, the equilateral triangular power pad arrangement is found to minimize the maximum voltage drop. This headline finding is a consequence of relatively simple formulas for the voltage drop, with explicit error bounds, which are established using complex analysis techniques, and elliptic functions in particular.
Resumo:
Résumé pour un large public: La vaccination a eu un impact énorme sur la santé mondiale. Mais, quel est le principe d'un vaccin? Il est basé sur la 'mémoire immunologique', qui est une particularité exclusive des systèmes immunitaires des organismes évolués. Suite à une infection par un pathogène, des cellules spécialisées de notre système immunitaire (les lymphocytes) le reconnaissent et initient une réaction immunitaire qui a pour but son élimination. Pendant cette réaction se développent aussi des cellules, appelées cellules lymphocytaires mémoire, qui persistent pour longue durée et qui ont la capacité de stimuler une réaction immunitaire très efficace immédiatement après une seconde exposition à ce même pathogène. Ce sont ces cellules mémoires (lymphocytes B et T) qui sont à la base de la 'mémoire immunologique' et qui sont stimulées lors de la vaccination. Chez l'homme, deux populations distinctes des lymphocytes T mémoires ont été identifiées: les cellules centrales (CM) et effectrices (EM) mémoires. Ces populations sont fonctionnellement hétérogènes et exercent des rôles distincts et essentiels dans l'immunité protectrice. Typiquement, les cellules effectrices mémoires sont capables de tuer immédiatement le pathogène tandis que les cellules centrales mémoires sont responsables d'initier une réponse immunitaire complète. Pourtant, les mécanismes biochimiques qui contrôlent les fonctions de ces cellules ont été jusqu'à présent peu étudiés à cause de la faible fréquence de ces cellules et de la quantité limitée de tissus humains disponibles pour les analyses. La compréhension de ces mécanismes est cruciale pour la réalisation de vaccins efficaces et pour le développement de nouveaux médicaments capables de moduler la réponse immunitaire lymphocytaire. Dans cette thèse, nous avons d'abord développé et amélioré une technologie appelée 'protéine array en phase inverse' qui possède un niveau de sensibilité beaucoup plus élevé par rapport aux technologies classiquement utilisées dans l'étude des protéines. Grâce à cette technique, nous avons pu comparer la composition protéique du système de transmission des signaux d'activation des cellules CM et EM humaines. L'analyse de 8 à 13 sujets sains a montré que ces populations des cellules mémoires possèdent un système de signalisation protéique différent. En effet, les cellules EM possèdent, par rapport aux cellules CM, des niveaux réduits d'une protéine régulatrice (appelée c-Cbl) que nous avons démontré comme étant responsable des fonctions spécifiques de ces cellules. En effet, en augmentant artificiellement l'expression de cette protéine régulatrice dans les cellules EM jusqu'au niveau de celui des cellules CM, nous avons induit dans les cellules EM des capacités fonctionnelles caractéristiques des cellules CM. En conclusion, notre étude a identifié, pour la première fois chez l'homme, un mécanisme biochimique qui contrôle les fonctions des populations des cellules mémoires. Résumé en Français: Les cellules mémoires persistent inertes dans l'organisme et produisent des réactions immunitaires rapides et robustes contre les pathogènes précédemment rencontrés. Deux populations distinctes des cellules mémoires ont été identifiées chez l'homme: les cellules centrales (CM) et effectrices (EM) mémoires. Ces populations sont fonctionnellement hétérogènes et exercent des rôles distincts et critiques dans l'immunité protectrice. Les mécanismes biochimiques qui contrôlent leurs fonctions ont été jusqu'à présent peu étudiés, bien que leur compréhension soit cruciale pour le développement des vaccins et des nouveaux traitements/médicaments. Les limites majeures à ces études sont la faible fréquence de ces populations et la quantité limitée de tissus humains disponibles. Dans cette thèse nous avons d'abord développé et amélioré la technologie de 'protéine array en phase inverse' afin d'analyser les molécules de signalisation des cellules mémoires CD4 et CD8 humaines isolées ex vivo. L'excellente sensibilité, la reproductibilité et la linéarité de la détection, ont permis de quantifier des variations d'expression protéiques supérieures à 20% dans un lysat équivalent à 20 cellules. Ensuite, grâce à l'analyse de 8 à 13 sujets sains, nous avons prouvé que les cellules mémoires CD8 ont une composition homogène de leur système de signalisation tandis que les cellules CD4 EM expriment significativement de plus grandes quantités de SLP-76 et des niveaux réduits de c-Cbl, Syk, Fyn et LAT par rapport aux cellules CM. En outre, l'expression réduite du régulateur négatif c-Cbl est corrélée avec l'expression des SLP-76, PI3K et LAT uniquement dans les cellules EM. L'évaluation des propriétés fonctionnelles des cellules mémoires a permis de démontrer que l'expression réduite du c-Cbl dans les cellules EM est associé à une diminution de leur seuil d'activation. En effet, grâce a la technique de transduction cytosolique, nous avons augmenté la quantité de c-Cbl des cellules EM à un niveau comparable à celui des cellules CM et constaté une réduction de la capacité des cellules EM à proliférer et sécréter des cytokines. Ce mécanisme de régulation dépend principalement de l'activité d'ubiquitine ligase de c-Cbl comme démontré par l'impact réduit du mutant enzymatiquement déficient de c-Cbl sur les fonctions de cellules EM. En conclusion, cette thèse identifie c-Cbl comme un régulateur critique des réponses fonctionnelles des populations de cellules T mémoires et fournit, pour la première fois chez l'homme, un mécanisme contrôlant l'hétérogénéité fonctionnelle des ces cellules. De plus, elle valide l'utilisation combinée des 'RPP arrays' et de la transduction cytosolique comme outil puissant d'analyse quantitative et fonctionnel des protéines de signalisation. Summary : Memory cells persist in a quiescent state in the body and mediate rapid and vigorous immune responses toward pathogens previously encountered. Two subsets of memory cells, namely central (CM) and effector (EM) memory cells, have been identified in humans. These subsets display high functional heterogeneity and assert critical and distinct roles in the control of protective immunity. The biochemical mechanisms controlling their functional properties remain so far poorly investigated, although their clarification is crucial for design of effective T-cell vaccine and drug development. Major limitations to these studies lie in the low frequency of memory T cell subsets and the limited amount of human specimen available. In this thesis we first implemented the innovative reverse phase protein array approach to profile 15 signalling components in human CD8 and CD4 memory T cells isolated ex vivo. The high degree of sensitivity, reproducibility and linearity achieved, allowed an excellent quantification of variations in protein expression higher than 20% in as few as 20-cell equivalent per spot. Based on the analysis of 8 to 13 healthy subjects, we showed that CD8 memory cells have a homogeneous composition of their signaling machinery while CD4 EM cells express statistically significant increased amounts of SLP-76 and reduced levels of c- Cbl, Syk, Fyn and LAT as compared to CM cells. Moreover, in EM but not CM cells, reduced expression of negative regulator c-Cbl correlated with the expression of SLP-76, PI3K and LAT. Subsequently, we demonstrated that the higher functional properties and the lower functional threshold of EM cells is associated with reduced expression of c-Cbl. Indeed, by increasing c-Cbl content of EM cells to the same level of CM cells using cytosolic transduction, we impaired their proliferation and cytokine production. This regulatory mechanism was primarily dependent on c-Cbl E3 ubiquitin ligase activity as evidenced by the weaker impact of enzymatically deficient c-Cbl C381A mutant on EM cell functions. Together, these results identify c-Cbl as a critical regulator of the functional responses of memory T cell subsets and provides, for the first time in humans, a mechanism controlling the functional heterogeneity of memory CD4 cells. Moreover it validates the combined use of RPP arrays and cytosolic transduction approaches as a powerful tool to quantitatively analyze signalling proteins and functionally assess their roles.
Resumo:
This thesis gives an overview of the validation process for thermal hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. The cases presented are not exhaustive, but they give a good overview of the work performed by the personnel of Lappeenranta University of Technology (LUT). Large part of the work has been performed in co-operation with the CATHARE-team in Grenoble, France. The design of a Russian type pressurized water reactor, VVER, differs from that of a Western-type PWR. Most of thermal-hydraulic system codes are validated only for the Western-type PWRs. Thus, the codes should be assessed and validated also for VVER design in order to establish any weaknesses in the models. This information is needed before codes can be used for the safety analysis. Theresults of the assessment and validation calculations presented here show that the CATHARE code can be used also for the thermal-hydraulic safety studies for VVER type plants. However, some areas have been indicated which need to be reassessed after further experimental data become available. These areas are mostly connected to the horizontal stem generators, like condensation and phase separation in primary side tubes. The work presented in this thesis covers a large numberof the phenomena included in the CSNI code validation matrices for small and intermediate leaks and for transients. Also some of the phenomena included in the matrix for large break LOCAs are covered. The matrices for code validation for VVER applications should be used when future experimental programs are planned for code validation.
Resumo:
In the electrical industry the 50 Hz electric and magnetic fields are often higher than in the average working environment. The electric and magnetic fields can be studied by measuring or by calculatingthe fields in the environment. For example, the electric field under a 400 kV power line is 1 to 10 kV/m, and the magnetic flux density is 1 to 15 µT. Electricand magnetic fields of a power line induce a weak electric field and electric currents in the exposed body. The average current density in a human being standing under a 400 kV line is 1 to 2 mA/m2. The aim of this study is to find out thepossible effects of short term exposure to electric and magnetic fields of electricity power transmission on workers' health, in particular the cardiovascular effects. The study consists of two parts; Experiment I: influence on extrasystoles, and Experiment II: influence on heart rate. In Experiment I two groups, 26 voluntary men (Group 1) and 27 transmission-line workers (Group 2), were measured. Their electrocardiogram (ECG) was recorded with an ambulatory recorder both in and outside the field. In Group 1 the fields were 1.7 to 4.9 kV/m and 1.1 to 7.1 pT; in Group 2 they were 0.1 to 10.2 kV/m and 1.0 to 15.4 pT. In the ECG analysis the only significant observation was a decrease in the heart rate after field exposure (Group 1). The drop cannot be explained with the first measuring method. Therefore Experiment II was carried out. In Experiment II two groups were used; Group 1 (26 male volunteers) were measured in real field exposure, Group 2 (15 male volunteers) in "sham" fields. The subjects of Group 1 spent 1 h outside the field, then 1 h in the field under a 400 kV transmission line, and then again 1 h outside the field. Under the 400 kV linethe field strength varied from 3.5 to 4.3 kV/m, and from 1.4 to 6.6 pT. Group 2spent the entire test period (3 h) in a 33 kV outdoor testing station in a "sham" field. ECG, blood pressure, and electroencephalogram (EEG) were measured by ambulatory methods. Before and after the field exposure, the subjects performed some cardiovascular autonomic function tests. The analysis of the results (Experiments I and II) showed that extrasystoles or arrythmias were as frequent in the field (below 4 kV/m and 4 pT) as outside it. In Experiment II there was no decrease detected in the heart rate, and the systolic and diastolic blood pressure stayed nearly the same. No health effects were found in this study.
Resumo:
The present study focuses on two effects of the presence of a noncondensable gas on the thermal-hydraulic behavior of thecoolant of the primary circuit of a nuclear reactor in the VVER-440 geometry inabnormal situations. First, steam condensation with the presence of air was studied in the horizontal tubes of the steam generator (SG) of the PACTEL test facility. The French thermal-hydraulic CATHARE code was used to study the heat transfer between the primary and secondary side in conditions derived from preliminary experiments performed by VTT using PACTEL. In natural circulation and single-phase vapor conditions, the injection of a volume of air, equivalent to the totalvolume of the primary side of the SG at the entrance of the hot collector, did not stop the heat transfer from the primary to the secondary side. The calculated results indicate that air is located in the second half-length (from the mid-length of the tubes to the cold collector) in all the tubes of the steam generator The hot collector remained full of steam during the transient. Secondly, the potential release of the nitrogen gas dissolved in the water of the accumulators of the emergency core coolant system of the Loviisa nuclear power plant (NPP) was investigated. The author implemented a model of the dissolution and release ofnitrogen gas in the CATHARE code; the model created by the CATHARE developers. In collaboration with VTT, an analytical experiment was performed with some components of PACTEL to determine, in particular, the value of the release time constant of the nitrogen gas in the depressurization conditions representative of the small and intermediate break transients postulated for the Loviisa NPP. Such transients, with simplified operating procedures, were calculated using the modified CATHARE code for various values of the release time constant used in the dissolution and release model. For the small breaks, nitrogen gas is trapped in thecollectors of the SGs in rather large proportions. There, the levels oscillate until the actuation of the low-pressure injection pumps (LPIS) that refill the primary circuit. In the case of the intermediate breaks, most of the nitrogen gas is expelled at the break and almost no nitrogen gas is trapped in the SGs. In comparison with the cases calculated without taking into account the release of nitrogen gas, the start of the LPIS is delayed by between 1 and 1.75 h. Applicability of the obtained results to the real safety conditions must take into accountthe real operating procedures used in the nuclear power plant.
Resumo:
Control applications of switched mode power supplies have been widely investigated. The main objective ofresearch and development (R&D) in this field is always to find the most suitable control method to be implemented in various DC/DC converter topologies. Inother words, the goal is to select a control method capable of improving the efficiency of the converter, reducing the effect of disturbances (line and load variation), lessening the effect of EMI (electro magnetic interference), and beingless effected by component variation. The main objective of this research work is to study different control methods implemented in switched mode power supplies namely (PID control, hysteresis control, adaptive control, current programmed control, variable structure control (VSC), and sliding mode control (SMC). The advantages and drawbacks of each control method are given. Two control methods, the PID and the SMC are selected and their effects on DC/DC (Buck, Boost, and Buck-Boost) converters are examined. Matlab/SimulinkTM is used to implement PID control method in DC/DC Buck converter and SMC in DC/DC (Buck, and Buck Boost) converters. For the prototype, operational amplifiers (op-amps) are used to implement PID control in DC/DC Buck converter. For SMC op-amps are implemented in DC/DC Buck converter and dSPACETM is used to control the DC/DC Buck-Boost converter. The SMC can be applied to the DC/DC (Buck, Boost, and Buck-Boost) converters. A comparison of the effects of the PID control and the SMC on the DC/DC Buck converter response in steady state, under line variations, load variations, and different component variations is performed. Also the Conducted RF-Emissions between the PID and SMC DC/DC Buck Converter are compared. The thesis shows that, in comparison with the PID control, the SMC provides better steady-state response, better dynamic response, less EMI, inherent order reduction, robustness against system uncertainty disturbances, and an implicit stability proof. Giving a better steady-state and dynamic response, the SMC is implemented in a DC/DC resonant converter. The half-wave zero current switching (HWZCS) DC/DC Buck converter is selected as a converter topology. A general guideline to select the tank component values, needed for the designing of a HWZCS DC/DC Buck, is obtained. The implementation of the SMC to a HWZCS DC/DC Buck converter is analysed. The converter response is investigated in the steady-state region and in the dynamic region.
Resumo:
Background: Design of newly engineered microbial strains for biotechnological purposes would greatly benefit from the development of realistic mathematical models for the processes to be optimized. Such models can then be analyzed and, with the development and application of appropriate optimization techniques, one could identify the modifications that need to be made to the organism in order to achieve the desired biotechnological goal. As appropriate models to perform such an analysis are necessarily non-linear and typically non-convex, finding their global optimum is a challenging task. Canonical modeling techniques, such as Generalized Mass Action (GMA) models based on the power-law formalism, offer a possible solution to this problem because they have a mathematical structure that enables the development of specific algorithms for global optimization. Results: Based on the GMA canonical representation, we have developed in previous works a highly efficient optimization algorithm and a set of related strategies for understanding the evolution of adaptive responses in cellular metabolism. Here, we explore the possibility of recasting kinetic non-linear models into an equivalent GMA model, so that global optimization on the recast GMA model can be performed. With this technique, optimization is greatly facilitated and the results are transposable to the original non-linear problem. This procedure is straightforward for a particular class of non-linear models known as Saturable and Cooperative (SC) models that extend the power-law formalism to deal with saturation and cooperativity. Conclusions: Our results show that recasting non-linear kinetic models into GMA models is indeed an appropriate strategy that helps overcoming some of the numerical difficulties that arise during the global optimization task.
Resumo:
INTRODUCTION: We examined the power spectral changes of the compound muscle action potential (M wave) evoked during isometric contractions of increasing strength. METHODS: Surface electromyography (sEMG) of the vastus lateralis and medialis was recorded from 20 volunteers who performed 4-s step-wise isometric contractions of different intensities. A maximal M wave was elicited by a single stimulus to the femoral nerve and superimposed on the voluntary contractions. The spectral characteristics (Fmean and Fmedian) of sEMG and M-wave signals were calculated. RESULTS: M-wave spectral indicators increased systematically with contraction intensity up to 60% MVC and then leveled off at higher forces. Over the 10-60% MVC range, the increase in spectral indicators was 3 times higher for M waves (36%) than for sEMG (12%). CONCLUSIONS: The consistent increase in M-wave spectral characteristics with force is due to the fact that the number of motor units recruited by the superimposed supramaximal stimulus is approximately stable.
Resumo:
Antisocial and criminal behaviors are multifactorial traits whose interpretation relies on multiple disciplines. Since these interpretations may have social, moral and legal implications, a constant review of the evidence is necessary before any scientific claim is considered as truth. A recent study proposed that men with wider faces relative to facial height (fWHR) are more likely to develop unethical behaviour mediated by a psychological sense of power. This research was based on reports suggesting that sexual dimorphism and selection would be responsible for a correlation between fWHR and aggression. Here we show that 4,960 individuals from 94 modern human populations belonging to a vast array of genetic and cultural contexts do not display significant amounts of fWHR sexual dimorphism. Further analyses using populations with associated ethnographical records as well as samples of male prisoners of the Mexico City Federal Penitentiary condemned by crimes of variable level of inter-personal aggression (homicide, robbery, and minor faults) did not show significant evidence, suggesting that populations/individuals with higher levels of bellicosity, aggressive behaviour, or power-mediated behaviour display greater fWHR. Finally, a regression analysis of fWHR on individual"s fitness showed no significant correlation between this facial trait and reproductive success. Overall, our results suggest that facial attributes are poor predictors of aggressive behaviour, or at least, that sexual selection was weak enough to leave a signal on patterns of between- and within-sex and population facial variation.
Resumo:
Electrically driven Er3+ doped Si slot waveguides emitting at 1530 nm are demonstrated. Two different Er3+ doped active layers were fabricated in the slot region: a pure SiO2 and a Si-rich oxide. Pulsed polarization driving of the waveguides was used to characterize the time response of the electroluminescence (EL) and of the signal probe transmission in 1 mm long waveguides. Injected carrier absorption losses modulate the EL signal and, since the carrier lifetime is much smaller than that of Er3+ ions, a sharp EL peak was observed when the polarization was switched off. A time-resolved electrical pump & probe measurement in combination with lock-in amplifier techniques allowed to quantify the injected carrier absorption losses. We found an extinction ratio of 6 dB, passive propagation losses of about 4 dB/mm, and a spectral bandwidth > 25 nm at an effective d.c. power consumption of 120 μW. All these performances suggest the usage of these devices as electro-optical modulators.
Resumo:
This study deals with the statistical properties of a randomization test applied to an ABAB design in cases where the desirable random assignment of the points of change in phase is not possible. In order to obtain information about each possible data division we carried out a conditional Monte Carlo simulation with 100,000 samples for each systematically chosen triplet. Robustness and power are studied under several experimental conditions: different autocorrelation levels and different effect sizes, as well as different phase lengths determined by the points of change. Type I error rates were distorted by the presence of autocorrelation for the majority of data divisions. Satisfactory Type II error rates were obtained only for large treatment effects. The relationship between the lengths of the four phases appeared to be an important factor for the robustness and the power of the randomization test.