972 resultados para Normal Distribution


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The large increase of Distributed Generation (DG) in Power Systems (PS) and specially in distribution networks makes the management of distribution generation resources an increasingly important issue. Beyond DG, other resources such as storage systems and demand response must be managed in order to obtain more efficient and “green” operation of PS. More players, such as aggregators or Virtual Power Players (VPP), that operate these kinds of resources will be appearing. This paper proposes a new methodology to solve the distribution network short term scheduling problem in the Smart Grid context. This methodology is based on a Genetic Algorithms (GA) approach for energy resource scheduling optimization and on PSCAD software to obtain realistic results for power system simulation. The paper includes a case study with 99 distributed generators, 208 loads and 27 storage units. The GA results for the determination of the economic dispatch considering the generation forecast, storage management and load curtailment in each period (one hour) are compared with the ones obtained with a Mixed Integer Non-Linear Programming (MINLP) approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper present a methodology to choose the distribution networks reconfiguration that presents the lower power losses. The proposed methodology is based on statistical failure and repair data of the distribution power system components and uses fuzzy-probabilistic modeling for system component outage parameters. The proposed hybrid method using fuzzy sets and Monte Carlo simulation based on the fuzzyprobabilistic models allows catching both randomness and fuzziness of component outage parameters. A logic programming algorithm is applied, once obtained the system states by Monte Carlo Simulation, to get all possible reconfigurations for each system state. To evaluate the line flows and bus voltages and to identify if there is any overloading, and/or voltage violation an AC load flow has been applied to select the feasible reconfiguration with lower power losses. To illustrate the application of the proposed methodology, the paper includes a case study that considers a 115 buses distribution network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Important research effort has been devoted to the topic of optimal planning of distribution systems. The non linear nature of the system, the need to consider a large number of scenarios and the increasing necessity to deal with uncertainties make optimal planning in distribution systems a difficult task. Heuristic techniques approaches have been proposed to deal with these issues, overcoming some of the inherent difficulties of classic methodologies. This paper considers several methodologies used to address planning problems of electrical power distribution networks, namely mixedinteger linear programming (MILP), ant colony algorithms (AC), genetic algorithms (GA), tabu search (TS), branch exchange (BE), simulated annealing (SA) and the Bender´s decomposition deterministic non-linear optimization technique (BD). Adequacy of theses techniques to deal with uncertainties is discussed. The behaviour of each optimization technique is compared from the point of view of the obtained solution and of the methodology performance. The paper presents results of the application of these optimization techniques to a real case of a 10-kV electrical distribution system with 201 nodes that feeds an urban area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Currently, power systems (PS) already accommodate a substantial penetration of distributed generation (DG) and operate in competitive environments. In the future, as the result of the liberalisation and political regulations, PS will have to deal with large-scale integration of DG and other distributed energy resources (DER), such as storage and provide market agents to ensure a flexible and secure operation. This cannot be done with the traditional PS operational tools used today like the quite restricted information systems Supervisory Control and Data Acquisition (SCADA) [1]. The trend to use the local generation in the active operation of the power system requires new solutions for data management system. The relevant standards have been developed separately in the last few years so there is a need to unify them in order to receive a common and interoperable solution. For the distribution operation the CIM models described in the IEC 61968/70 are especially relevant. In Europe dispersed and renewable energy resources (D&RER) are mostly operated without remote control mechanisms and feed the maximal amount of available power into the grid. To improve the network operation performance the idea of virtual power plants (VPP) will become a reality. In the future power generation of D&RER will be scheduled with a high accuracy. In order to realize VPP decentralized energy management, communication facilities are needed that have standardized interfaces and protocols. IEC 61850 is suitable to serve as a general standard for all communication tasks in power systems [2]. The paper deals with international activities and experiences in the implementation of a new data management and communication concept in the distribution system. The difficulties in the coordination of the inconsistent developed in parallel communication and data management standards - are first addressed in the paper. The upcoming unification work taking into account the growing role of D&RER in the PS is shown. It is possible to overcome the lag in current practical experiences using new tools for creating and maintenance the CIM data and simulation of the IEC 61850 protocol – the prototype of which is presented in the paper –. The origin and the accuracy of the data requirements depend on the data use (e.g. operation or planning) so some remarks concerning the definition of the digital interface incorporated in the merging unit idea from the power utility point of view are presented in the paper too. To summarize some required future work has been identified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new and efficient methodology for distribution network reconfiguration integrated with optimal power flow (OPF) based on a Benders decomposition approach. The objective minimizes power losses, balancing load among feeders and subject to constraints: capacity limit of branches, minimum and maximum power limits of substations or distributed generators, minimum deviation of bus voltages and radial optimal operation of networks. The Generalized Benders decomposition algorithm is applied to solve the problem. The formulation can be embedded under two stages; the first one is the Master problem and is formulated as a mixed integer non-linear programming problem. This stage determines the radial topology of the distribution network. The second stage is the Slave problem and is formulated as a non-linear programming problem. This stage is used to determine the feasibility of the Master problem solution by means of an OPF and provides information to formulate the linear Benders cuts that connect both problems. The model is programmed in GAMS. The effectiveness of the proposal is demonstrated through two examples extracted from the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy Resources Management can play a very relevant role in future power systems in SmartGrid context, with high penetration of distributed generation and storage systems. This paper deals with the importance of resources management in incident situation. The system to consider a high penetration of distributed generation, demand response, storage units and network reconfiguration. A case study evidences the advantages of using a flexible SCADA to control the energy resources in incident situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess different factors influencing adiponectinemia in obese and normal-weight women; to identify factors associated with the variation (Δ) in adiponectinemia in obese women following a 6-month weight loss program, according to surgical/non-surgical interventions. Methods: We studied 100 normal-weight women and 112 obese premenopausal women; none of them was on any medical treatment. Women were characterized for anthropometrics, daily macronutrient intake, smoking status, contraceptives use, adiponectin as well as IL-6 and TNF-α serum concentrations. Results: Adiponectinemia was lower in obese women (p < 0.001), revealing an inverse association with waist-to-hip ratio (p < 0.001; r = –0.335). Normal-weight women presented lower adiponectinemia among smokers (p = 0.041); body fat, waist-to-hip ratio, TNF-α levels, carbohydrate intake, and smoking all influence adiponectinemia (r 2 = 0.436). After weight loss interventions, a significant modification in macronutrient intake occurs followed by anthropometrics decrease (chiefly after bariatric procedures) and adiponectinemia increase (similar after surgical and non-surgical interventions). After bariatric intervention, Δ adiponectinemia was inversely correlated to Δ waist circumference and Δ carbohydrate intake (r 2 = 0.706). Conclusion: Anthropometrics, diet, smoking, and TNF-α levels all influence adiponectinemia in normal-weight women, although explaining less than 50% of it. In obese women, anthropometrics modestly explain adiponectinemia. Opposite to non-surgical interventions, after bariatric surgery adiponectinemia increase is largely explained by diet composition and anthropometric changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado, Estudos Integrados dos Oceanos, 20 de Março de 2014, Universidade dos Açores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

World Congress of Malacology, Ponta Delgada, July 22-28, 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

25th Annual Conference of the European Cetacean Society, Cadiz, Spain 21-23 March 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MOVECLIM, Mid Course Meeting, 2-6 September 2013, Réunion (Mascarenes).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Copyright © 2014 Entomological Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims at investigating the impact of treating breast cancer using different radiation therapy (RT) techniques – forwardly-planned intensity-modulated, f-IMRT, inversely-planned IMRT and dynamic conformal arc (DCART) RT – and their effects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB treatment planning system were compared: Pencil Beam Convolution (PBC) and commercial Monte Carlo (iMC). Seven left-sided breast patients submitted to breast-conserving surgery were enrolled in the study. For each patient, four RT techniques – f-IMRT, IMRT using 2-fields and 5-fields (IMRT2 and IMRT5, respectively) and DCART – were applied. The dose distributions in the planned target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose–volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all techniques provided adequate coverage of the PTV. However, statistically significant dose differences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung and heart than tangential techniques. However, IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Differences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the iMC algorithm predicted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For some years now, translation theorist and educator Anthony Pym has been trying to establish a dialogue between the academic tradition he comes from and the world of the language industries into which he is meant to introduce his students: in other words, between the Translation Studies discipline and the localisation sector. This rapprochement is also the stated aim of his new book The Moving Text (p. 159). Rather than collect and synthesise what was previously dispersed over several articles, Pym has rewritten his material completely, both literally and conceptually, all in the light of the more than three decades of research he has conducted into the field of cross--cultural communication. The theoretical arguments are ably supported by a few short but telling and well-exploited examples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho surgiu no âmbito da Tese de Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química, aliando a necessidade da Empresa Monteiro Ribas – Indústrias, S.A. em resolver alguns problemas relacionados com as estufas da unidade J da fábrica de revestimentos. Outro dos objectivos era propor melhorias de eficiência energética neste sector da empresa. Para tal, foi necessário fazer um levantamento energético de toda a unidade, o que permitiu verificar que as estufas de secagem (Recobrimento 1 e 2) seriam o principal objecto de estudo. O levantamento energético da empresa permitiu conhecer o seu consumo anual de energia de 697,9 tep, o que a classifica, segundo o Decreto-lei nº 71 de 15 de Abril de 2008, como Consumidora Intensiva de Energia (CIE). Além disso, as situações que devem ser alvo de melhoria são: a rede de termofluido, que apresenta válvulas sem isolamento, o sistema de iluminação, que não é o mais eficiente e a rede de distribuição de ar comprimido, que não tem a estrutura mais adequada. Desta forma sugere-se que a rede de distribuição de termofluido passe a ter válvulas isoladas com lã de rocha, o investimento total é de 2.481,56 €, mas a poupança pode ser de 21.145,14 €/ano, com o período de retorno de 0,12 anos. No sistema de iluminação propõe-se a substituição dos balastros normais por electrónicos, o investimento total é de 13.873,74 €, mas a poupança é de 2.620,26 €/ano, com período de retorno de 5 anos. No processo de secagem das linhas de recobrimento mediram-se temperaturas de todos os seus componentes, velocidades de ar o que permitiu conhecer a distribuição do calor fornecido pelo termofluido. No Recobrimento 1, o ar recebe entre 39 a 51% do calor total, a tela recebe cerca de 25% e na terceira estufa este é apenas de 6%. Nesta linha as perdas de calor por radiação oscilam entre 6 e 11% enquanto as perdas por convecção representam cerca de 17 a 44%. Como o calor que a tela recebe é muito inferior ao calor recebido pelo ar no Recobrimento 1, propõe-se uma redução do caudal de ar que entra na estufa, o que conduzirá certamente à poupança de energia térmica. No Recobrimento 2 o calor fornecido ao ar representa cerca de 51 a 77% do calor total e o cedido à tela oscila entre 2 e 3%. As perdas de calor por convecção oscilam entre 12 e 26%, enquanto que as perdas por radiação têm valores entre 4 e 8%. No que diz respeito ao calor necessário para evaporar os solventes este oscila entre os 4 e 13%. Os balanços de massa e energia realizados ao processo de secagem permitiram ainda determinar o rendimento das 3 estufas do Recobrimento 1, com 36, 47 e 24% paras as estufa 1, 2 e 3, respectivamente. No Recobrimento 2 os valores de rendimento foram superiores, tendo-se obtido valores próximos dos 41, 81 e 88%, para as estufas 1, 2 e 3, respectivamente. Face aos resultados obtidos propõem-se a reengenharia do processo introduzindo permutadores compactos para aquecer o ar antes de este entrar nas estufas. O estudo desta alteração foi apenas realizado para a estufa 1 do Recobrimento 1, tendo-se obtido uma área de transferência de calor de 6,80 m2, um investimento associado de 8.867,81 €. e uma poupança de 708,88 €/ano, com um período de retorno do investimento de 13 anos. Outra sugestão consiste na recirculação de parte do ar de saída (5%), que conduz à poupança de 158,02 €/ano. Estes valores, pouco significativos, não estimulam a adopção das referidas sugestões.