981 resultados para N-body simulation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Hiehojen elopainon määrittäminen mittauksin alkukasvatusvaiheessa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CoFe-Ag-Cu granular films, prepared by rf sputtering, displayed magnetic domain microstructures for ferromagnetic concentrations above about 32% at, and below the percolation threshold. All samples have a fcc structure with an (111) texture perpendicular to the film plane. Magnetic force microscopy (MFM) showed a variety of magnetic domain microstructures, extremely sensitive to the magnetic history of the sample, which arise from the balance of the ferromagnetic exchange, the dipolar interactions and perpendicular magnetocrystalline anisotropy, MFM images indicate that in virgin samples, magnetic bubble domains with an out-of-plane component of the magnetization are surrounded by a quasicontinuous background of opposite magnetization domains. The application of a magnetic field in different geometries drastically modifies the microstructure of the system in the remanent state: i) for an in-plane field, the MFM images show that most of the magnetic moments are aligned along the film plane, ii) for an out-of-plane field, the MFM signal increases about one order of magnitude, and out-of-plane striped domains with alternating up and down magnetization are stabilized. Numerical simulations show that a variety of metastable domain structures (similar to those observed experimentally) can be reached, depending on magnetic history, in systems with competing perpendicular anisotropy, exchange and dipolar interactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Both structural and dynamical properties of 7Li at 470 and 843 K are studied by molecular dynamics simulation and the results are comapred with the available experimental data. Two effective interatomic potentials are used, i.e., a potential derived from the Ashcroft pseudopotential [Phys. Lett. 23, 48 (1966)] and a recently proposed potential deduced from the neutral pseudoatom method [J. Phys.: Condens. Matter 5, 4283 (1993)]. Although the shape of the two potential functions is very different, the majority of the properties calculated from them are very similar. The differences among the results using the two interaction models are carefully discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The self-intermediate dynamic structure factor Fs(k,t) of liquid lithium near the melting temperature is calculated by molecular dynamics. The results are compared with the predictions of several theoretical approaches, paying special attention to the Lovesey model and the Wahnstrm and Sjgren mode-coupling theory. To this end the results for the Fs(k,t) second memory function predicted by both models are compared with the ones calculated from the simulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Growth is a central process in paediatrics. Weight and height evaluation are therefore routine exams for every child but in some situation, particularly inflammatory bowel disease (IBD), a wider evaluation of nutritional status needs to be performed. Objectives: To assess the accuracy of bio-impedance analysis (BIA) compared to the gold standard dual energy X-ray absorptiometry (DEXA) in estimating percentage body fat (fat mass; FM) and lean body mass (fat free mass; FFM) in children with inflammatory bowel disease (IBD). To compare FM and FFM levels between patients with IBD and healthy controls. Methods: Twenty-nine healthy controls (12 females; mean age: 12.7 ± 1.9 years) and 21 patients (11 females; 14.3 ± 1.3 years) were recruited from August 2011 to October 2012 at our institution. BIA was performed in all children and DEXA in patients only. Concordance between BIA and DEXA was assessed using Lin's concordance correlation and the Bland-Altman method. Between-group comparisons were made using analysis of variance adjusting for age. Results: BIA-derived FM% showed a good concordance with DEXA-derived values, while BIA-derived FFM% tended to be slightly higher than DEXA-derived values (table). No differences were found between patients and controls regarding body mass index (mean ± SD: 19.3 ± 3.3 vs. 20.1 ± 2.8 kg/m2, respectively; age-adjusted P = 0.08) and FM% (boys: 25.3 ± 10.2 vs. 22.6 ± 7.1%, for patients and controls, respectively; P = 0.20; girls: 28.2 ± 5.7 vs. 26.4 ± 7.7%; P = 0.91). Also, no differences were found regarding FFM% in boys (74.9 ± 10.2 vs. 77.4 ± 7.1%; P = 0.22) and girls (71.8 ± 5.6 vs. 73.5 ± 7.7%; P = 0.85). Conclusion: BIA adequately assesses body composition (FM%) in children with IBD and could advantageously replace DEXA, which is more expensive and less available. No differences in body composition were found between children with IBD and healthy controls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atribution as a function of the time are analyzed and this study leads to a deeper knowledge of the microscopic processes involved in the magnetic relaxation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context: Foreign body aspiration (FbA) is a serious problem in children. Accurate clinical and radiographic diagnosis is important because missed or delayed diagnosis can result in respiratory difficulties ranging from life-treatening airway obstruction to chronic wheezing or recurrent pneumonia. Bronchoscopy also has risks and accurate clinical and radiographc diagnosis can support the decision of bronchoscopy. Objective: To rewiev the diagnostic accuracy of clinical presentation (CP) and pulmonary radiograph (PR) for the diagnosis of FbA. There is no previous rewievMethods: A search of Medline is conducted for articles containing data regarding CP and PR signes of FbA. Calculation of likelihood ratios (LR) and pre and post test probability using Bayes theorem were performed for all signs of CP and PR. Inclusion criteria: Articles containing prospective data regarding CP and PR of FbA. Exclusion criteria: Retrospectives studies. Articles containing incomplete data for calculation of LR. Results: Five prospectives studies are included with a total of 585 patients. Prevalence of FbA is 63% in children suspected of FbA. If CP is normal, probability of FbA is 25% and if PR is normal, probability is 14%. If CP is pathologic, probability of FbA is 69-76% with presence of cough (LR = 1.32) or dyspnea (LR = 1.84) or localized crackles (LR = 1.5). Probability is 81-88% if cyanosis (LR = 4.8) or decreased breaths sounds (LR = 4.3) or asymetric auscultation (LR = 2.9) or localized wheezing (LR = 2.5) are present. When CP is anormal and PR show mediatinal shift (LR = 100), pneumomediatin (LR = 100), radio opaque foreign body (LR = 100), lobar distention (LR = 4), atelectasis (LR = 2.5), inspiratory/expiratory abnormal (LR = 7), the probability of FbA is 96-100%. If CP is normal and PR is abnormal the probability is 40-100%. If CP is abnormal and PR is normal the probability is 55-75%. Conclusions: This rewiev of prospective studies demonstrates the importance of CP and PR and an algorithm can be proposed. When CP is abnormal with or without PR pathologic, the probability of FbA is high and bronchoscopy is indicated. When CP and PR are normal the probability of FbA is low and bronchoscopy is not necessary immediatly, observation should be proposed. This approach should be validated with prospective study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Self- and cross-velocity correlation functions and related transport coefficients of molten salts are studied by molecular-dynamics simulation. Six representative systems are considered, i.e., NaCl and KCl alkali halides, CuCl and CuBr noble-metal halides, and SrCl2 and ZnCl2 divalent metal-ion halides. Computer simulation results are compared with experimental self-diffusion coefficients and electrical conductivities. Special attention is paid to dynamic cross correlations and their dependence on the Coulomb interactions as well as on the size and mass differences between anions and cations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Body fluid biomarkers of central nervous system damage may help improve the prognostic and diagnostic accuracy in ischemic stroke. We studied 53 patients. Stroke severity and outcome was rated using the National Institutes of Health Stroke Scale and modified Rankin scale. Ferritin, S100B, and NfH were measured in cerebrospinal fluid (CSF) and serum. Infarct volume was calculated from T2W images. CSF S100B (median 1.00 ng/mL) and CSF ferritin (10.0 ng/mL) levels were elevated in patients with stroke compared with control subjects (0.62 ng/mL, P < .0001; 2.34 ng/mL, P < .0001). Serum S100B (0.09 ng/mL) was higher in patients with stroke compared with control subjects (0.01 ng/mL). CSF S100B levels were higher in patients with a cardioembolic stroke (2.88 ng/mL) than in those with small-vessel disease (0.89 ng/mL, P < .05). CSF S100B levels correlated with the National Institutes of Health Stroke Scale score on admission (R = 0.56, P < .01) and the stroke volume (R = 0.44, P = .01). CSF S100B and NfH-SMI35 levels correlated with outcome on the modified Rankin scale. CSF S100B levels were related to stroke severity and infarct volume and highest in cardioembolic stroke.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the diagnostic performance of abdominal radiography in the detection of illegal intracorporeal containers (hereafter, packets), with low-dose computed tomography (CT) as the reference standard. MATERIALS AND METHODS: This study was approved by the institutional ethical review board, with written informed consent. From July 2007 to July 2010, 330 people (296 men, 34 women; mean age, 32 years [range, 18-55 years]) suspected of having ingested drug packets underwent supine abdominal radiography and low-dose CT. The presence or absence of packets at abdominal radiography was reported, with low-dose CT as the reference standard. The density and number of packets (≤ 12 or >12) at low-dose CT were recorded and analyzed to determine whether those variables influence interpretation of results at abdominal radiography. RESULTS: Packets were detected at low-dose CT in 53 (16%) suspects. Sensitivity of abdominal radiography for depiction of packets was 0.77 (41 of 53), and specificity was 0.96 (267 of 277). The packets appeared isoattenuated to the bowel contents at low-dose CT in 16 (30%) of the 53 suspects with positive results. Nineteen (36%) of the 53 suspects with positive low-dose CT results had fewer than 12 packets. Packets that were isoattenuated at low-dose CT and a low number of packets (≤12) were both significantly associated with false-negative results at abdominal radiography (P = .004 and P = .016, respectively). CONCLUSION: Abdominal radiography is mainly limited by low sensitivity when compared with low-dose CT in the screening of people suspected of carrying drug packets. Low-dose CT is an effective imaging alternative to abdominal radiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A general mapping between the energy of pertinent magnetic solutions and the diagonal terms of the spin Hamiltonian in a local representation provides the first general framework to extract accurate values for the many body terms of extended spin Hamiltonians from periodic first-principle calculations. Estimates of these terms for La2CuO4, the paradigm of high-Tc superconductor parent compounds, and for the SrCu2O3 ladder compound are reported. For La2CuO4, present results support experimental evidence by Toader et al. [Phys. Rev. Lett. 94, 197202 (2005)]. For SrCu2O3 even larger four-body spin amplitudes are found together with Jl/Jr=1 and non-negligible ferromagnetic interladder exchange.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A general mapping between the energy of pertinent magnetic solutions and the diagonal terms of the spin Hamiltonian in a local representation provides the first general framework to extract accurate values for the many body terms of extended spin Hamiltonians from periodic first-principle calculations. Estimates of these terms for La2CuO4, the paradigm of high-Tc superconductor parent compounds, and for the SrCu2O3 ladder compound are reported. For La2CuO4, present results support experimental evidence by Toader et al. [Phys. Rev. Lett. 94, 197202 (2005)]. For SrCu2O3 even larger four-body spin amplitudes are found together with Jl/Jr=1 and non-negligible ferromagnetic interladder exchange.