998 resultados para Musaeus, Johannes, 1613-1681


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Proteinuria and hyperphosphatemia are cardiovascular risk factors independent of GFR. We hypothesized that proteinuria induces relative phosphate retention via increased proximal tubule phosphate reabsorption. To test the clinical relevance of this hypothesis, we studied phosphate handling in nephrotic children and patients with CKD. Plasma fibroblast growth factor 23 (FGF-23) concentration, plasma phosphate concentration, and tubular reabsorption of phosphate increased during the proteinuric phase compared with the remission phase in nephrotic children. Cross-sectional analysis of a cohort of 1738 patients with CKD showed that albuminuria≥300 mg/24 hours is predictive of higher phosphate levels, independent of GFR and other confounding factors. Albuminuric patients also displayed higher plasma FGF-23 and parathyroid hormone levels. To understand the molecular mechanisms underlying these observations, we induced glomerular proteinuria in two animal models. Rats with puromycin-aminonucleoside-induced nephrotic proteinuria displayed higher renal protein expression of the sodium-phosphate co-transporter NaPi-IIa, lower renal Klotho protein expression, and decreased phosphorylation of FGF receptor substrate 2α, a major FGF-23 receptor substrate. These findings were confirmed in transgenic mice that develop nephrotic-range proteinuria resulting from podocyte depletion. In vitro, albumin did not directly alter phosphate uptake in cultured proximal tubule OK cells. In conclusion, we show that proteinuria increases plasma phosphate concentration independent of GFR. This effect relies on increased proximal tubule NaPi-IIa expression secondary to decreased FGF-23 biologic activity. Proteinuria induces elevation of both plasma phosphate and FGF-23 concentrations, potentially contributing to cardiovascular disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Parece mentira que una pieza teatral firmada por Calderón de la Barca haya tardado más de tres cientos años en aparecer impresa y que sea ahora,en el 2010, cuando lo haga por primera vez. ¿A qué se debe esta falta de interés por la obra?La respuestanos la ofrecen Felipe B. Pedza Jiménez y Rafael González Cañal en el capítulo que abre el estudio preliminar de su edicion tulado«Razones de una sin razón»

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper reviews the historical transformation of the European regulatory framework for electronic communications from the era dominated by state-owned enterprises to the presence of regulated competition. In the course of these developments, the vision of the roles of the public and private sectors in electronic communications changed in expected and unexpected ways. While the period is characterized by a shift toward less direct state intervention, the intensity of regulation has increased in many areas. Most recently, in the wake of the financial crisis, new forms of state intervention can be observed, including public investment in communications infrastructure and public-private partnerships. As a result of the reforms, Europe has been able to achieve major successes but it also suffered unanticipated setbacks compared to other regions. The European Union emerged as the global leader in mobile communications during the 1990s and was able to roll-out first-generation broadband access networks more rapidly than many of its peers. Recently, however, Europe as a whole has not performed as well in deploying next-generation networks and advanced mobile communications services. The paper offers a political-economic explanation for these developments and assesses their effects on the performance of the European electronic communications sector and the economy. From this analysis, the European model emerges as a unique institutional arrangement with peculiar advantages and disadvantages. Once these are recognized, sensible next steps to build the strengths while avoiding the weaknesses of the model can be seen more clearly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In radionuclide metrology, Monte Carlo (MC) simulation is widely used to compute parameters associated with primary measurements or calibration factors. Although MC methods are used to estimate uncertainties, the uncertainty associated with radiation transport in MC calculations is usually difficult to estimate. Counting statistics is the most obvious component of MC uncertainty and has to be checked carefully, particularly when variance reduction is used. However, in most cases fluctuations associated with counting statistics can be reduced using sufficient computing power. Cross-section data have intrinsic uncertainties that induce correlations when apparently independent codes are compared. Their effect on the uncertainty of the estimated parameter is difficult to determine and varies widely from case to case. Finally, the most significant uncertainty component for radionuclide applications is usually that associated with the detector geometry. Recent 2D and 3D x-ray imaging tools may be utilized, but comparison with experimental data as well as adjustments of parameters are usually inevitable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This chapter presents possible uses and examples of Monte Carlo methods for the evaluation of uncertainties in the field of radionuclide metrology. The method is already well documented in GUM supplement 1, but here we present a more restrictive approach, where the quantities of interest calculated by the Monte Carlo method are estimators of the expectation and standard deviation of the measurand, and the Monte Carlo method is used to propagate the uncertainties of the input parameters through the measurement model. This approach is illustrated by an example of the activity calibration of a 103Pd source by liquid scintillation counting and the calculation of a linear regression on experimental data points. An electronic supplement presents some algorithms which may be used to generate random numbers with various statistical distributions, for the implementation of this Monte Carlo calculation method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses basic theoretical strategies used to deal with measurement uncertainties arising from different experimental situations. It attempts to indicate the most appropriate method of obtaining a reliable estimate of the quantity to be evaluated depending on the characteristics of the data available. The theoretical strategies discussed are supported by experimental detail, and the conditions and results have been taken from examples in the field of radionuclide metrology. Special care regarding the correct treatment of covariances is emphasized because of the unreliability of the results obtained if these are neglected

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The 4πβ-γ coincidence counting method and its close relatives are widely used for the primary standardization of radioactivity. Both the general formalism and specific implementation of these methods have been well-documented. In particular, previous papers contain the extrapolation equations used for various decay schemes, methods for determining model parameters and, in some cases, tabulated uncertainty budgets. Two things often lacking from experimental reports are both the rationale for estimating uncertainties in a specific way and the details of exactly how a specific component of uncertainty was estimated. Furthermore, correlations among the components of uncertainty are rarely mentioned. To fill in these gaps, the present article shares the best-practices from a few practitioners of this craft. We explain and demonstrate with examples of how these approaches can be used to estimate the uncertainty of the reported massic activity. We describe uncertainties due to measurement variability, extrapolation functions, dead-time and resolving-time effects, gravimetric links, and nuclear and atomic data. Most importantly, a thorough understanding of the measurement system and its response to the decay under study can be used to derive a robust estimate of the measurement uncertainty.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The aims of this study were to determine the etiology, clinical features, and predictors of outcome of new-onset refractory status epilepticus. METHODS: Retrospective review of patients with refractory status epilepticus without etiology identified within 48 hours of admission between January 1, 2008, and December 31, 2013, in 13 academic medical centers. The primary outcome measure was poor functional outcome at discharge (defined as a score >3 on the modified Rankin Scale). RESULTS: Of 130 cases, 67 (52%) remained cryptogenic. The most common identified etiologies were autoimmune (19%) and paraneoplastic (18%) encephalitis. Full data were available in 125 cases (62 cryptogenic). Poor outcome occurred in 77 of 125 cases (62%), and 28 (22%) died. Predictors of poor outcome included duration of status epilepticus, use of anesthetics, and medical complications. Among the 63 patients with available follow-up data (median 9 months), functional status improved in 36 (57%); 79% had good or fair outcome at last follow-up, but epilepsy developed in 37% with most survivors (92%) remaining on antiseizure medications. Immune therapies were used less frequently in cryptogenic cases, despite a comparable prevalence of inflammatory CSF changes. CONCLUSIONS: Autoimmune encephalitis is the most commonly identified cause of new-onset refractory status epilepticus, but half remain cryptogenic. Outcome at discharge is poor but improves during follow-up. Epilepsy develops in most cases. The role of anesthetics and immune therapies warrants further investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pressurized re-entrant (or 4 pi) ionization chambers (ICs) connected to current-measuring electronics are used for activity measurements of photon emitting radionuclides and some beta emitters in the fields of metrology and nuclear medicine. As a secondary method, these instruments need to be calibrated with appropriate activity standards from primary or direct standardization. The use of these instruments over 50 years has been well described in numerous publications, such as the Monographie BIPM-4 and the special issue of Metrologia on radionuclide metrology (Ratel 2007 Metrologia 44 S7-16, Schrader1997 Activity Measurements With Ionization Chambers (Monographie BIPM-4) Schrader 2007 Metrologia 44 S53-66, Cox et al 2007 Measurement Modelling of the International Reference System (SIR) for Gamma-Emitting Radionuclides (Monographie BIPM-7)). The present work describes the principles of activity measurements, calibrations, and impurity corrections using pressurized ionization chambers in the first part and the uncertainty analysis illustrated with example uncertainty budgets from routine source-calibration as well as from an international reference system (SIR) measurement in the second part.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador: