964 resultados para Monoclonal antibodies


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An in house indirect immmunofluorescence assay ( IFA ) in relation to neutralization (NT) reference test, was assessed as a fast and cheap method to carry out serological surveys for St. Louis Encephalitis virus (SLE). Sera obtained from 213 blood donors were analyzed by both tests. The prevalence of seropositivity obtained with IFA was lower than (30.98%) that observed on NT (41.78%). The relative specificity rate of IFA was 96.77% whereas its relative sensitivity rate was 69.66%. Kappa index showed a good correlation between both tests. The results indicate that neutralization assay is still the serological test with the highest sensitivity and specificity relative rates for detecting antibodies against SLE virus. Nevertheless, the IFA could be useful as an alternative test in order to learn the circulation of the Flavivirus genus in a certain area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering the impact of cysticercosis on public health, especially the neurologic form of the disease, neurocysticercosis (NC), we studied the frequency of positivity of anti-Taenia solium cysticercus antibodies in serum samples from 1,863 inhabitants of Cássia dos Coqueiros, SP, a municipal district located 80 km from Ribeirão Preto, an area considered endemic for cysticercosis. The 1,863 samples were tested by enzyme linked immunosorbent assay (ELISA) using an antigenic extract from Taenia crassiceps vesicular fluid (Tcra). The reactive and inconclusive ELISA samples were tested by immunoblotting. Of the 459 samples submitted to immunoblotting, 40 were strongly immunoreactive to the immunodominant 18 and 14 kD peptides. Considering the use of immunoblotting as confirmatory due to its high specificity, the anti-cysticercus serum prevalence in this population was 2.1%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simple and rapid latex-based diagnostic tests have been used for detecting specific antigens or antibodies in several diseases. In this article, we present the preliminary results obtained with a latex agglutination test (LAT) for diagnosing neurocysticercosis by detection of antibodies in CSF. A total of 43 CSF samples were assayed by the LAT: 19 CSF samples from patients with neurocysticercosis and 24 CSF samples from patients with other neurologic disorders (neurosyphilis, n = 8; neurotoxoplasmosis, n = 3; viral meningitis, n = 4, chronic headache, n = 9). The LAT exhibited 89.5% sensitivity and 75% specificity. The use of LAT seems to be an additional approach for the screening of neurocysticercosis with advantage of simplicity and rapidity. Further studies could be performed using purified antigens and serum samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of the rabies neutralizing antibody (VNA) response after immunization against rabies is an acceptable index of the efficacy of a vaccine and a successful treatment. Several tests have been developed in attempt to improve the assessment of VNA, from mice inoculation to cell-culture fluorescence inhibition tests. All of them, however, present special difficulties in terms of reading or accuracy. The present study describes a neutralization test performed in cell-culture appraised by flow cytometry (FC). Serial dilutions of the serum samples were mixed in vitro with rabies virus before the addition of BHK-21 cells. After 24h-incubation, cells were released by trypsin treatment, fixed and permeabilized with a p-formaldehyde solution and stained with a rabies virus nucleocapsid protein-specific antibody conjugate. The percentage of virus infection inhibition caused by specific antibodies present in the serum were evaluated in a Beckton & Dickinson FACSCalibur® flow cytometer. A correlation curve between the IU/ml content and the percentage of infective inhibition was built with a reference serum and the VNA titers of serum samples were obtained by extrapolation. Titers obtained by FC and standard test showed an effective pairing results (p < 0.01), with a correlation coefficient (r) = 0.7. These results permit to envisage the FC as a suitable technique to evaluate VNA in sera from immunized animals and likely in human serum samples. Nevertheless, new studies comparing FC to gold-standard techniques are required for determining the FC values of Sensibility and Specificity .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prevalence of anti-human parvovirus B19 IgG antibodies was determined in sera from 165 chronic hemolytic anemia patients, receiving medical care at Instituto Estadual de Hematologia (IEHE), Rio de Janeiro, during the year of 1994. This sample represents around 10% of the chronic hemolytic anemia patients attending at IEHE. Most of these patients (140) have sickle cell disease. Anti-B19 IgG antibodies were detected in 32.1% of patients. No statistically significant difference (p > 0.05) was seen between IgG antibody prevalence in male (27.8%) and female (35.5%) patients. Anti-B19 IgG antibodies were more frequent in older (37.6%) than younger (28.2%) than 20 years old patients, although this difference had no statistical significance (p > 0.05). Anti-B19 IgG antibody prevalence showed that 67.9% of patients enrolled in the study were susceptible to B19 acute infection. With the aim to detect acute B19 infection, patients follow up continued until February 1996. During this period four patients presented transient aplastic crisis due to human parvovirus B19 as confirmed by the detection of specific IgM antibodies. All four patients were younger than 20 years old, and 3 were younger than 10 years old. Three of them were sickle cell disease patients. Three of the four acute B19 infection occurred during 1994 springtime.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Serological survey was performed to detect IgG antibodies anti-Taenia solium metacestodes in blood donors of Hemocentro Regional de Uberlândia, Minas Gerais, Brazil. A total of 1133 sera from blood donors coming from four cities of Triângulo Mineiro area were analyzed by the indirect fluorescence antibody test (IFAT) and the enzyme linked immunosorbent assay (ELISA). Specific IgG antibodies were found in 5.6% of the studied population, showing differences in the positive rates according to their origin: Araguari (13.5%), Tupaciguara (5.0%), Monte Alegre de Minas (4.8%) and Uberlândia (4.7%). The results indicate the probable endemicity of cysticercosis in this population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Serum samples from 497 children and adults inhabiting two neighbourhoods (Guamá and Terra Firme) in Belém, Pará, North Brazil were screened for the presence of human herpesvirus 8 (HHV-8) antibody using an enzyme-linked immunosorbent assay. An overall 16.3% prevalence was found for these urban communities. Taken both genders together, prevalence rates of HHV-8 antibody increase gradually, across age-groups, ranging from 12.0% to 33.3%. When seroprevalence is analysed by gender, similar rates are found for female (18.4%) and male (14.0%) individuals. In the former gender group, seroprevalence rates increased from 10.3%, in children £ 10 years of age, to 30.0% in adults 41-50 years of age. Conversely, among male subjects, the prevalence of HHV-8 antibodies decreased from 13.3% in children/young adults aged £ 10 to 20 years of age to 6.1% in adults aged 21-30 years. From the 31-40 year-old group male onwards, seropositivity rates increased gradually, ranging from 8.3% to 66.7%. A significant difference in seropositivity rates was noted when comparing 21-30 age groups for female and male subjects: 23.3% and 6.1%, respectively (P = 0.03). Geometric mean optical densities were found to increase slightly from the lower to the higher age-groups. Our data suggest that transmission of HHV-8 occurs frequently in the general urban population of Belém, and that prevalence of antibody seems to increase with age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents the results of the detection of antibodies (immunoglobulin G) for subtypes I and VI of VEE viruses complex (Togaviridae family) in people from the General Belgrano island, Formosa province (Argentina). The prevalence of neutralizing (NT) antibodies for subtype VI was from 30% to 70% and the prevalence of antibodies inhibitory of hemagglutination (HI) was of 0% in the first and second inquiry respectively. For the subtype IAB the prevalence of NT antibodies was from 13% to 3.6%, similar to the prevalence total for both subtypes. HI antibodies were not detected in any inquiries for any subtype. It was observed that both subtypes circulate simultaneously, while subtype VI remains constant with some peaks, subtype I was found in low level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human chorionic gonadotropin (hCG) is a key diagnostic marker of pregnancy and an important biomarker for cancers in the prostate, ovaries and bladder and therefore of great importance in diagnosis. For this purpose, a new immunosensor of screen-printed electrodes (SPEs) is presented here. The device was fabricated by introducing a polyaniline (PANI) conductive layer, via in situ electropolymerization of aniline, onto a screen-printed graphene support. The PANI-coated graphene acts as the working electrode of a three terminal electrochemical sensor. The working electrode is functionalised with anti-hCG, by means of a simple process that enabled oriented antibody binding to the PANI layer. The antibody was attached to PANI following activation of the –COOH group at the Fc terminal. Functionalisation of the electrode was analysed and optimized using Electrochemical Impedance Spectroscopy (EIS). Chemical modification of the surface was characterised using Fourier transform infrared, and Raman spectroscopy with confocal microscopy. The graphene–SPE–PANI devices displayed linear responses to hCG in EIS assays from 0.001 to 50 ng mL−1 in real urine, with a detection limit of 0.286 pg mL−1. High selectivity was observed with respect to the presence of the constituent components of urine (urea, creatinine, magnesium chloride, calcium chloride, sodium dihydrogen phosphate, ammonium chloride, potassium sulphate and sodium chloride) at their normal levels, with a negligible sensor response to these chemicals. Successful detection of hCG was also achieved in spiked samples of real urine from a pregnant woman. The immunosensor developed is a promising tool for point-of-care detection of hCG, due to its excellent detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A serological survey of Toxoplasma gondii infection in blood donors was carried out in order to identify seroprevalence in Recife, Brazil. Sera from 160 individuals (119 male and 41 female) were evaluated by using a Toxoplasma IgG-antibody enzyme immunoassay (Denka Seiken Co., LTD., Tokyo, Japan). The seropositive percentual for males (79.0%) showed to be higher (p < 0.05) than for females (63.4%). This percentage increases with age, ranging from 18.2% to 92.6% for individuals aging under 20 and 40-50 years old, respectively. For women of childbearing age (18-40 years) it was found a prevalence of 51.6%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Renal damage is an important cause of death in patients who have survived the early effects of severe crotalid envenomation. Extracellular matrix of renal tissue is altered by Crotalus toxin activities. The aim of this study was to describe how cytoskeletal proteins and basal membrane components undergo substantial alterations under the action of Crotalus vegrandis crude venom and its hemorrhagic fraction (Uracoina-1) in mice. To detect the proteins in question, the immunoperoxidase method with monoclonal and polyclonal antibodies was used. Cell types within renal lesions were characterized by phenotypic identification, by means of immunohistologic analysis of marker proteins using different primary antibodies against mesangial cells, endothelial cells, cytoskeletal proteins (intermediate filament), extracellular matrix and basal membranes. Samples for morphological study by standard procedures (biotin-streptavidin-peroxidase technique) using light microscopy were processed. Positive and negative controls for each antigen tested in the staining assay were included. After crude venom and hemorrhagic fraction inoculation of mice, the disappearance of cytoskeletal vimentin and desmin and collagen proteins in the kidney was observed. In extracellular matrix and basal membranes, collagen type IV from envenomed animals tends to disappear from 24 h to 120 h after venom injection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using low cost portable devices that enable a single analytical step for screening environmental contaminants is today a demanding issue. This concept is here tried out by recycling screen-printed electrodes that were to be disposed of and by choosing as sensory element a low cost material offering specific response for an environmental contaminant. Microcystins (MCs) were used as target analyte, for being dangerous toxins produced by cyanobacteria released into water bodies. The sensory element was a plastic antibody designed by surface imprinting with carefully selected monomers to ensure a specific response. These were designed on the wall of carbon nanotubes, taking advantage of their exceptional electrical properties. The stereochemical ability of the sensory material to detect MCs was checked by preparing blank materials where the imprinting stage was made without the template molecule. The novel sensory material for MCs was introduced in a polymeric matrix and evaluated against potentiometric measurements. Nernstian response was observed from 7.24 × 10−10 to 1.28 × 10−9 M in buffer solution (10 mM HEPES, 150 mM NaCl, pH 6.6), with average slopes of −62 mVdecade−1 and detection capabilities below 1 nM. The blank materials were unable to provide a linear response against log(concentration), showing only a slight potential change towards more positive potentials with increasing concentrations (while that ofthe plastic antibodies moved to more negative values), with a maximum rate of +33 mVdecade−1. The sensors presented good selectivity towards sulphate, iron and ammonium ions, and also chloroform and tetrachloroethylene (TCE) and fast response (<20 s). This concept was successfully tested on the analysis of spiked environmental water samples. The sensors were further applied onto recycled chips, comprehending one site for the reference electrode and two sites for different selective membranes, in a biparametric approach for “in situ” analysis.