997 resultados para Meyer, Marvin


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Heart transplantation (HTx) is the treatment of choice for end-stage heart failure but the limited availability of heart's donors still represents a major issue. So long-term mechanical circulatory support (MCS) has been proposed as an alternative treatment option to assist patients scheduled on HTx waiting list bridging them for a variable time period to cardiac transplantation-the so-called bridge-to-transplantation (BTT) strategy. Nowadays approximately 90% of patients being considered for MCS receive a left ventricular assist device (LVAD). In fact, LVAD experienced several improvements in the last decade and the predominance of continuous-flow over pulsatile-flow technology has been evident since 2008. The aim of the present report is to give an overview of continuous-flow LVAD utilization in the specific setting of the BTT strategy taking into consideration the most representative articles of the scientific literature and focusing the attention on the evolution, clinical outcomes, relevant implications on the HTx strategy and future perspectives of the continuous-flow LVAD technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Therapeutic hypothermia following hypoxic ischaemic encephalopathy in term infants was introduced into Switzerland in 2005. Initial documentation of perinatal and resuscitation details was poor and neuromonitoring insufficient. In 2011, a National Asphyxia and Cooling Register was introduced. AIMS: To compare management of cooled infants before and after introduction of the register concerning documentation, neuromonitoring, cooling methods and evaluation of temperature variability between cooling methods. STUDY DESIGN: Data of cooled infants before the register was in place (first time period: 2005-2010) and afterwards (second time period: 2011-2012) was collected with a case report form. RESULTS: 150 infants were cooled during the first time period and 97 during the second time period. Most infants were cooled passively or passively with gel packs during both time periods (82% in 2005-2010 vs 70% in 2011-2012), however more infants were cooled actively during the second time period (18% versus 30%). Overall there was a significant reduction in temperature variability (p < 0.001) comparing the two time periods. A significantly higher proportion of temperature measurements within target temperature range (72% versus 77%, p < 0.001), fewer temperature measurements above (24% versus 7%, p < 0.001) and more temperatures below target range (4% versus 16%, p < 0.001) were recorded during the second time period. Neuromonitoring improved after introduction of the cooling register. CONCLUSION: Management of infants with HIE improved since introducing the register. Temperature variability was reduced, more temperature measurements in the target range and fewer temperature measurements above target range were observed. Neuromonitoring has improved, however imaging should be performed more often.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Metastatic melanomas are frequently refractory to most adjuvant therapies such as chemotherapies and radiotherapies. Recently, immunotherapies have shown good results in the treatment of some metastatic melanomas. Immune cell infiltration in the tumor has been associated with successful immunotherapy. More generally, tumor infiltrating lymphocytes (TILs) in the primary tumor and in metastases of melanoma patients have been demonstrated to correlate positively with favorable clinical outcomes. Altogether, these findings suggest the importance of being able to identify, quantify and characterize immune infiltration at the tumor site for a better diagnostic and treatment choice. In this paper, we used Fourier Transform Infrared (FTIR) imaging to identify and quantify different subpopulations of T cells: the cytotoxic T cells (CD8+), the helper T cells (CD4+) and the regulatory T cells (T reg). As a proof of concept, we investigated pure populations isolated from human peripheral blood from 6 healthy donors. These subpopulations were isolated from blood samples by magnetic labeling and purities were assessed by Fluorescence Activated Cell Sorting (FACS). The results presented here show that Fourier Transform Infrared (FTIR) imaging followed by supervised Partial Least Square Discriminant Analysis (PLS-DA) allows an accurate identification of CD4+ T cells and CD8+ T cells (>86%). We then developed a PLS regression allowing the quantification of T reg in a different mix of immune cells (e.g. Peripheral Blood Mononuclear Cells (PBMCs)). Altogether, these results demonstrate the sensitivity of infrared imaging to detect the low biological variability observed in T cell subpopulations.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To optimize and preliminarily evaluate a three-dimensional (3D) radial balanced steady-state free precession (bSSFP) arterial spin labeled (ASL) sequence for nonenhanced MR angiography (MRA) of the extracranial carotid arteries. MATERIALS AND METHODS: The carotid arteries of 13 healthy subjects and 2 patients were imaged on a 1.5 Tesla MRI system using an undersampled 3D radial bSSFP sequence providing a scan time of ∼4 min and 1 mm(3) isotropic resolution. A hybridized scheme that combined pseudocontinuous and pulsed ASL was used to maximize arterial coverage. The impact of a post label delay period, the sequence repetition time, and radiofrequency (RF) energy configuration of pseudocontinuous labeling on the display of the carotid arteries was assessed with contrast-to-noise ratio (CNR) measurements. Faster, higher undersampled 2 and 1 min scans were tested. RESULTS: Using hybridized ASL MRA and a 3D radial bSSFP trajectory, arterial CNR was maximized with a post label delay of 0.2 s, repetition times ≥ 2.5 s (P < 0.05), and by eliminating RF energy during the pseudocontinuous control phase (P < 0.001). With higher levels of undersampling, the carotid arteries were displayed in ≤ 2 min. CONCLUSION: Nonenhanced MRA using hybridized ASL with a 3D radial bSSFP trajectory can display long lengths of the carotid arteries with 1 mm(3) isotropic resolution. J. Magn. Reson. Imaging 2015;41:1150-1156. © 2014 Wiley Periodicals, Inc.